Valid

GB/T 40661-2021Calibration specification of measurement instrument for power frequency magnetic field (English PDF)

工频磁场测量仪校准规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for GB/T 40661-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 11, 2021

Implementation date

May 1, 2022

Scope

GB/T 40661-2021 is the English-translated version of 工频磁场测量仪校准规范.

GB/T 40661-2021 is the Chinese national calibration specification for instruments that measure power frequency magnetic fields. It covers new, in-use and repaired instruments measuring power frequency magnetic induction at a rated frequency of 50 Hz, whether of the electromagnetic induction or the Hall effect type.

It sets general requirements such as a sturdy housing, locking connectors between units, a low-battery indication and the information on the nameplate, and then the calibration parameters, calibration conditions, calibration items and methods, the processing of results and the calibration interval.

Informative annexes give a calibration method for power frequency electric field meters, a calibration record form and a method for evaluating the uncertainty of calibration results. It was issued on 11 October 2021 and has applied since 1 May 2022.

Found what you need?

Document preview — GB/T 40661-2021

National Standard of the People's Republic of China

ICS
17.220.20
Classification
A 75

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Overview
  • 4 General requirements
  • 5 Calibration parameter requirements
  • 6 Calibration conditions
  • 7 Calibration items and calibration methods
  • 8 Calibration result processing
  • 9 Calibration interval
  • Appendix A (informative) Calibration method of power frequency electric field measuring instrument
  • Appendix B (Informative) Calibration Record Form of Power Frequency Magnetic Field Measuring Instrument
  • Appendix C (Informative) Uncertainty Evaluation Method for Calibration Results of Power Frequency Magnetic Field Measuring Instruments
  • Reference

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.

1 Scope

This document specifies the general requirements, calibration parameter requirements, calibration conditions, calibration items and calibration methods, calibration results for power frequency magnetic field measuring instruments. Requirements such as fruit, calibration interval, etc.

This document is applicable to new-manufactured, in-use, and repaired magnetic field measuring instruments that measure power frequency magnetic induction with a rated frequency of 50 Hz Calibration.

Note: Refer to Appendix A for the calibration method of the power frequency electric field measuring instrument for measuring the power frequency electric field intensity.

2 Normative references

The content of the following documents constitutes an indispensable clause of this document through normative references in the text. Among them, dated quotations Only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 17626.8 Electromagnetic compatibility test and measurement technology Power frequency magnetic field immunity test

3 Overview

The power frequency magnetic field measuring instrument is composed of a sensing unit, a signal processing and a display unit. It can be split or integral. When measuring The sensing unit is fixed at the measuring position through a bracket and a support.

Commonly used power frequency magnetic field measuring instruments are electromagnetic induction type and Hall effect type. Electromagnetic induction type is generated in the detection coil based on AC magnetic flux The principle of induced electric potential works and is suitable for measuring the magnetic field generated by a high-power source. The Hall effect type is affected by the current flow through the semiconductor material.

The principle that the magnetic field perpendicular to the surface generates voltage at both ends works, and it is suitable for measuring the magnetic field generated by various power sources.

4 General requirements

4.1 The housing of the power frequency magnetic field measuring instrument should have sufficient mechanical strength, and the combination with the bracket, support, and handle should be reliable and not loose.

4.2 The plugs and sockets used to insert the signal transmission line between the working units of the power frequency magnetic field measuring instrument should have a locking mechanism.

4.3 For measuring instrument units that use batteries, there should be an instruction to replace the battery when the battery power is low.

4.4 There should be a nameplate mark on the housing of the power frequency magnetic field measuring instrument, which includes.

---name;

---Model specifications;

---Manufacturing plant;

---Product number;

--- Error limit (can also be included in the manual);

---Sensitive direction (if not marked, it is the normal direction).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 40661-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40661-2021

$285.00