Valid

GB/T 40357-2021Hair products—Determination of the permeability of hairpiece to air (English PDF)

发制品 假发透气性的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 40357-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

August 20, 2021

Implementation date

December 1, 2021

Scope

GB/T 40357-2021 is the English-translated version of 发制品 假发透气性的测定.

GB/T 40357-2021 describes how to measure the air permeability of the cap base of hair products. It applies to wigs and hairpieces with a cap base structure made mainly of human hair, chemical fibres or other hair.

Under a specified pressure difference, the air flow passing through a defined area of the cap base in a given time is measured and the air permeability is calculated.

Conditioning and testing take place in the atmosphere of GB/T 6529. The equipment includes a hemispherical test bench with a radius of (67.5 ± 1.0) mm, whose test holes total 38.0 cm² or 20.0 cm² in cross-sectional area, the smaller bench serving products with a small cap base, and a hemispherical clamping device fitted with rubber washers. It was issued on 20 August 2021 and has applied since 1 December 2021.

Found what you need?

Document preview — GB/T 40357-2021

National Standard of the People's Republic of China

ICS
59.080.99
Classification
W 59

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Principle
  • 5 Atmosphere for humidity control and test
  • 6 Equipment

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.

1 Scope

This document specifies the testing method for the air permeability of hair products.

This document is applicable to wigs, wigs and wigs with a cap bottom structure made of all kinds of human hair, chemical fibers and other hair as the main raw materials. Hair block.

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 6529 Standard atmosphere for textile humidity control and testing

GB/T 8170 Numerical rounding rules and the expression and determination of limit values

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Air permeability of hair products

Under the specified test cross-sectional area, pressure drop and time conditions, the air permeability of hair products.

4 Principle

Under the specified pressure difference condition, measure the air flow through the measured area of the hair product cap bottom within a certain period of time, and calculate the air permeability.

5 Atmosphere for humidity control and test

The air for humidity control and test shall be implemented in accordance with the regulations in GB/T 6529.

6 Equipment

6.1 Test bench. It is composed of a hemisphere with a radius of (67.5±1.0)mm, and the upper part of the hemisphere has a cut angle of 40°±0.5° (see Appendix A). Figure A.1). In the spherical part of the hemisphere, there are a number of air permeability test holes in concentric positions, uniformly distributed and uniform in size. The total cross-sectional area of the hole should be 38.0 (1±0.3%) cm² or 20.0 (1±0.3%) cm².For products with small cap bottom area, test can be used For a test bench with a cross-sectional area of 20.0 (1±0.3%) cm², see A.1 and A.3.for the structure diagram of the test bench.

6.2 Clamping device. It is composed of a hemisphere with a radius of (65.0±1.0)mm, and the upper part of the hemisphere is a cut angle of 40°±0.5° (see Figure A.2), there should be at least 3 rings of rubber washers (6.3) on the cut surface. In the spherical part of the hemisphere, there are several concentric circles. Air permeability test circular holes with uniform cloth and uniform size. The total cross-sectional area of the circular holes should be at least the same as the total cross-sectional area of the circular holes of the selected test bench (6.1).

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 40357-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40357-2021

$150.00