GB/T 40114-2021Jewellery—Determination of precious metal content—Difference method using inductively coupled plasma optical emission spectroscopy (English PDF)
首饰 贵金属含量的测定 ICP差减法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 40114-2021 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 21, 2021
Implementation date
December 1, 2021
Scope
GB/T 40114-2021 is the English-translated version of 首饰 贵金属含量的测定 ICP差减法.
GB/T 40114-2021 sets out a difference method for finding the precious metal content of gold, platinum and palladium alloy jewellery: instead of measuring the precious metal itself, the laboratory measures the impurity elements by inductively coupled plasma optical emission spectroscopy and subtracts their total.
It covers gold alloys from 725 per thousand to 999 per thousand and platinum and palladium alloys from 800 per thousand to 999 per thousand.
The document lists the reagents, including how to prepare the standard stock solutions of gold, palladium, silver, copper, nickel, cobalt, iron, zinc, cadmium and platinum, the spectrometer, balance and glassware, the test procedure, the calculation of impurity and precious metal content, the repeatability limits and the content of the test report.
It is meant for jewellery testing laboratories. It replaces GB/T 21198.6-2007, was issued on 21 May 2021 and has applied since 1 December 2021.
Found what you need?
Document preview — GB/T 40114-2021
National Standard of the People's Republic of China
- ICS
- 39.060
- Classification
- Y 88
- Replacing
- GB/T 21198.6-2007
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope5
- 2 Normative References5
- 3 Terms and Definitions5
- 4 Principle6
- 5 Reagents and Materials6
- 6 Instruments8
- 7 Test Procedures9
- 8 Calculation of Results10
- 9 Repeatability11
- 10 Test Report11
- Appendix A (Informative) Recommended Test Analysis Line13
1 Scope
This Document specifies a method for determining the content of precious metals by determining the content of impurity elements in gold, platinum, and palladium alloy jewellery.
This Document is applicable to gold alloy jewellery with gold content of 725 per thousand~999 per thousand, platinum alloy jewellery with platinum content of 800 per thousand~999 per thousand, and palladium alloy jewellery with palladium content of 800 per thousand~999 per thousand.
NOTE: The applicable measurement range of the precious metal content is the range covered by the precision test. It may also be applicable beyond this range, but the laboratory is required to verify the test beyond the range.
2 Normative References
The following documents are essential to the application of this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this Document.
GB/T 12806-2011 Laboratory Glassware - One-Mark Volumetric Flasks
GB/T 12808-2015 Laboratory Glassware - One Mark Pipettes
3 Terms and Definitions
For the purposes of this Document, there are no terms and definitions that shall be given.
5 Reagents and Materials
5.17 Gold standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure gold (5.2); place it in a 50mL beaker. Add 10mL of mixed acid (5.16) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask; add 105mL of hydrochloric acid (5.13); dilute to the mark with water and shake well.
5.18 Palladium standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure palladium (5.3); place it in a 50mL beaker. Add 10mL of mixed acid (5.16) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask' add 105mL of hydrochloric acid (5.13); dilute to the mark with water and shake well.
5.19 Silver standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure silver (5.4); place it in a 50mL beaker. Add 10mL of nitric acid (5.15) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask pre-filled with 92mL of hydrochloric acid (5.11). Wash the beaker with a small amount of water; incorporate the lotion into a volumetric flask; shake until the precipitate is dissolved. Dilute to the mark with hydrochloric acid (5.14), and shake well.
5.20 Copper standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure copper (5.5); place it in a 50mL beaker. Add 10mL of nitric acid (5.15) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask; add 115mL of hydrochloric acid (5.13); and dilute with water to the mark, and shake well.
5.21 Nickel standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure nickel (5.6); place it in a 50mL beaker. Add 10mL of nitric acid (5.15) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask; add 115mL of hydrochloric acid (5.13); dilute with water to the mark, and shake well.
5.22 Cobalt standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure cobalt (5.7); place it in a 50mL beaker. Add 10mL of nitric acid (5.15) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask; add 120mL of hydrochloric acid (5.13); dilute with water to the mark, and shake well.
5.23 Iron standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure iron (5.8); place it in a 50mL beaker. Add 10mL of hydrochloric acid (5.13) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask; add 120mL of hydrochloric acid (5.13); dilute with water to the mark, and shake well.
5.24 Zinc standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure zinc (5.9); place it in a 50mL beaker. Add 10mL of hydrochloric acid (5.13) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask; add 120mL of hydrochloric acid (5.13); dilute with water to the mark, and shake well.
5.25 Cadmium standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure cadmium (5.10); place it in a 50mL beaker. Add 10mL of mixed acid (5.16) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask, add 115mL of hydrochloric acid (5.13); dilute with water to the mark, and shake well.
5.26 Platinum standard stock solution (200µg/mL)
Weigh (100±0.01) mg of pure platinum (5.1); place it in a 50mL beaker. Add 10mL of mixed acid (5.16) solution; slowly heat to dissolve. After cooling, transfer to a 500mL volumetric flask; add 115mL of hydrochloric acid (5.13); dilute to the mark with water, and shake well.
5.27 Standard stock solutions or mixed standard stock solutions of iridium, rhodium, ruthenium, bismuth, manganese, lead, tin, magnesium, silicon, arsenic, antimony, and chromium
National certified standard samples or standard substances may be purchased.
6 Instruments
6.1 Inductively coupled plasma emission spectrometer: wavelength resolution <= 0.01nm. The detection limit of the measured element is better than 0.02mg/L, and it has a background correction function.
6.2 Micro-electronic balance: The actual graduation value is no more than 0.01mg; and the accuracy level is Level-.
6.3 Single line pipette: Class-A in GB/T 12808-2015. Or adjustable pipette.
6.4 Single line volumetric flask: Class-A in GB/T 12806-2011.
8 Calculation of Results
rhoi - concentration of the tested elements of the specimen solution, in µg/mL;
rhoi0 - concentration of the tested elements of the blank solution, in µg/mL;
V - volume of the specimen solution, in mL; m - mass of the specimen, in mg.
If rhoi - rhoi0 <= limit of detection, take the limit of detection as the (rhoi - rhoi0) value to introduce for calculation; thereof, the limit of detection is 3 times the standard deviation of the 11 test results of the concentration of each element in the corresponding reagent blank solution.
According to the relative intensity of the target element of the unknown sample, use the calibration curve to calculate the content of the element to be measured. The test result of the element to be tested shall be within the content range of a series of calibration samples used in the calibration curve.
8.2 Calculation of precious metal content
The precious metal content omega is expressed in per thousand; and calculated according to Formula (2):
The calculation results shall be expressed to one digit after the decimal point.
9 Repeatability
If the absolute difference of the total amounts of the tested elements (8.1) is no more than 40 per thousand of the arithmetic mean of the two tested values (8.1), for samples with a purity of more than 995 per thousand, the absolute difference of the results of parallel determination of the precious metal content is no more than 0.2 per thousand. If it is greater than this value, it shall be tested again.
10 Test Report
The test report shall include:
a) The identification of the sample, including the source, the date of receiving the sample, the shape of the sample, and the date of the test;
b) The number of the used standard;
c) The permillage of the precious metal content of the specimen is calculated in […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 40114
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 40114-2021 | Jewellery—Determination of precious metal content—Difference method using inductively coupled plasma optical emission spectroscopy | current edition | Current |
| GB/T 21198.6-2007 | Jewellery—Determination of precious metal content—Difference method using inductively coupled plasma optical emission spectroscopy | previous edition | Superseded |
This page sells the current edition, GB/T 40114-2021. Earlier editions are listed for reference only.
How to Download GB/T 40114-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12806-2011 — Laboratory glassware -- One-mark volumetric flasks
GB/T 12808-2015 — Laboratory glassware - One mark pipettes
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 40114-2021
$150.00