Valid

GB/T 40110-2021Surface chemical analysis - Determination of surface elemental contamination on silicon wafers by total-reflection X-ray fluorescence (TXRF) spectroscopy (English PDF)

Also coversGBT40110-2021

Open the GB/T 40110-2021 preview as PDF

Preview — first pages of GB/T 40110-2021

This is a limited preview

Buy now to download the full PDF

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

May 21, 2021

Implementation date

December 1, 2021

Scope

GB/T 40110-2021 (Surface chemical analysis - Determination of surface elemental contamination on silicon wafers by total-reflection X-ray fluorescence (TXRF) spectroscopy) is available as an English-translated PDF.

GB/T 40110-2021 — This document describes TXRF that measures the surface density of atoms contaminated by elements on the surface of silicon wafers that have been chemically mechanically polished or epitaxially grown. method. This document applies to the following situations. ---Elements with atomic numbers from 16 (S) to 92 (U); ---Polluting elements with atomic surface density between 1x1010atoms/cm2~1x1014atoms/cm2; ---The atomic surface density obtained by the VPD (Vapour Phase Decomposition) sample preparation method is between 5x108atoms/cm2~5x1012at- Contaminant elements between oms/cm2 (see 3.4).

Document preview — GB/T 40110-2021

National Standard of the People's Republic of China

Classification
G 04

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • 1 Scope1
  • 2 Normative references1
  • 3 Terms and definitions1
  • 4 Abbreviations2
  • 5 Principle2
  • 6 Equipment2
  • 7 Sample preparation and measurement environment2
  • 8 Calibration reference materials3
  • 9 Security3
  • 10 Measurement procedure3
  • 11 Result expression4
  • 12 Precision5
  • 13 Test report5
  • Appendix A (informative) Reference material6
  • Appendix B (informative) Relative sensitivity factor7
  • Appendix C (informative) Preparation of reference materials10
  • Appendix D (informative) VPD-TXRF method13
  • Appendix E (Informative) Glance Angle Setting14
  • Appendix F (informative) International inter-laboratory test results17
  • Reference20

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1.Structure and Drafting Rules of Standardization Documents"

Drafting.

This document is equivalent to ISO 14706.2014 "Surface Chemical Analysis Total Reflection X-ray Fluorescence Spectrometry (TXRF) Determination of Silicon Wafer Surface

Surface element pollution."

The Chinese documents that have consistent correspondence with the normatively cited international documents in this document are as follows.

---GB/T 25915.1-2010 Clean room and related controlled environment Part 1.Air cleanliness level (ISO 14644-1.

1999, IDT)

Introduction

This document is formulated for the need to measure elemental contamination on the surface of silicon wafers. It is based on ASTMF1526, SEMIM33, and basic semiconductors.

A UCS issued by the Institute of Basic Semiconductor Technology Development (Institute of Basic Semiconductor Technology Development)

(Ultra-CleanSociety, Ultra-Clean Society) developed on the basis of standardized documents.

TXRF requires the use of reference materials for quantitative analysis. A certified reference material with an atomic surface density lower than 1010atoms/cm2 is difficult

To get. Even if it is available, pollution introduced from the environment may shorten the validity period of these reference materials.

For calibration purposes, relevant analytical laboratories will need to prepare and analyze TXRF reference materials. Therefore, it needs to be formulated separately

Two standardized documents are prepared for TXRF measurement procedures and reference materials. This document is the former, which is about the standardization of TXRF measurement procedures

file.

Surface chemical analysis

Total reflection X-ray fluorescence spectrometry (TXRF)

Determination of element contamination on the surface of silicon wafers

1 Scope

This document describes TXRF that measures the surface density of atoms contaminated by elements on the surface of silicon wafers that have been chemically mechanically polished or epitaxially grown.

method.

This document applies to the following situations.

---Elements with atomic numbers from 16 (S) to 92 (U);

---Polluting elements with atomic surface density between 1x1010atoms/cm2~1x1014atoms/cm2;

---The atomic surface density obtained by the VPD (Vapour Phase Decomposition) sample preparation method is between 5x108atoms/cm2~5x1012at-

Contaminant elements between oms/cm2 (see 3.4).

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations

Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to

This document.

ISO 14644-1 Clean room and related control environment Part 1.Air cleanliness level (Cleanrooms and associated

controledenvironments-Part 1.Classificationofaircleanliness)

3 Terms and definitions

The following terms and definitions apply to this document.

3.1

Total reflection

When grazing incident X-rays are irradiated to a medium with a larger X-ray density, the complete reflection occurs at the boundary of the two mediums.

Note. The refractive index of silicon wafers for X-rays is less than 1.X-rays incident on the surface of the silicon wafer at a small grazing angle will be totally reflected on the surface of the silicon wafer.

The angle of fire is equal to the glancing angle.

3.2

Glancing angle

The angle between the plane of the sample surface and the virtual plane containing the X-rays incident on the sample surface.

3.3

Criticalangle

The grazing angle corresponding to the first inflection point in the graph of sample matrix X-ray fluorescence intensity and grazing angle.

3.4

VPD-TXRF method VPD-TXRF method

A method of collecting surface impurities through the VPD program. Use a drop of collection reagent (usually ultra-pure hydrofluoric acid) to collect oxygen on the surface of the silicon wafer

The non-volatile product formed after the acid decomposition of the compound is then dried in the least polluted environment, and the final droplet residue formed is used

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

ISO 14644

How to Buy GB/T 40110-2021

  1. 1Add to cart. Click the "Buy GB/T 40110-2021" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40110-2021

$440.00

$375.00for partners