Valid

GB/T 40091-2021Requirements for safety measures of relaying protection and security automatic equipment in smart substation (English PDF)

智能变电站继电保护和电网安全自动装置安全措施要求

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 40091-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

April 30, 2021

Implementation date

November 1, 2021

Scope

GB/T 40091-2021 is the English-translated version of 智能变电站继电保护和电网安全自动装置安全措施要求.

GB/T 40091-2021 sets the safety measures to be taken during on-site work on relay protection and power grid security automatic devices in smart substations, and on the related secondary equipment and secondary circuits.

It covers the general requirements for such work, the procedure for secondary safety measures, and how these measures are drawn up, implemented and restored.

The general requirements include compliance with GB 26860, knowledge of the primary and secondary equipment involved, work tickets and operation tickets, control of substation configuration files, information security with dedicated computers and storage media, and stopping work at once if an abnormal situation or a circuit breaker trip occurs.

Informative annexes give a form for secondary work safety measures and examples of typical isolation points. It was issued on 30 April 2021 and has applied since 1 November 2021.

Found what you need?

Document preview — GB/T 40091-2021

National Standard of the People's Republic of China

ICS
29.240.99
Classification
K 45

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 General requirements
  • 5 Secondary security measures process
  • 6 Requirements for the formulation of secondary safety measures
  • 7 Implementation requirements for secondary security measures
  • 8 Recovery requirements for secondary security measures
  • Appendix A (informative appendix) Form of secondary work safety measures (vote)
  • Appendix B (informative appendix) Example 8 of typical isolation points for secondary safety measures

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard was proposed and managed by the China Electricity Council.

1 Scope

This standard stipulates that the relay protection of smart substations and automatic power grid safety devices, related secondary equipment and secondary circuits shall comply with the on-site work. The overall requirements of the cycle, the procedures of the secondary security measures, the requirements for the formulation of secondary security measures, the requirements for the implementation of secondary security measures, and the restoration of secondary security measures Complex requirements.

This standard applies to the field work of intelligent substation relay protection and power grid security automatic devices, related secondary equipment and secondary circuits.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document. For undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 20840.7 Transformer Part 7: Electronic Voltage Transformer

GB/T 20840.8 Transformer Part 8: Electronic Current Transformer

GB 26860 Electrical Safety Work Rules for the Electrical Part of Power Plants and Substations

DL/T 860 (all parts) Substation communication network and system

DL/T 995 Inspection Regulations for Relay Protection and Power Grid Security Automatic Devices

3 Terms and definitions

The terms and definitions defined in GB/T 20840.7, GB/T 20840.8, GB 26860, DL/T 860 (all parts), and DL/T 995 are suitable Used in this document.

4 General requirements

4.1 In addition to the implementation of GB 26860, the on-site work of smart substations should also comply with the provisions of this standard on secondary safety measures.

4.2 On-site operators should understand the working location, scope of work, electrical main wiring, related primary equipment and secondary equipment operation, and be familiar with Relay protection, power grid security automatic devices and related secondary circuits, fully assess the impact of field operations on related secondary equipment or circuits.

4.3 The on-site work should comply with relevant regulations or rules such as work tickets, operation tickets, secondary work safety measures (tickets), standardized operations, and risk identification. system.

4.4 The management and control of smart substation configuration files should be done well.

4.5 On-site work should comply with relevant regulations and systems for information security, and dedicated computers should be used for information operations such as online and file copying. And secure storage media.

4.6 In the process of on-site work, in the event of an abnormal situation or a circuit breaker tripping, the work should be stopped immediately, and the status quo should be maintained, pending investigation of the cause. determine It has nothing to do with this job and can only continue to work after getting permission. If the abnormal situation or the tripping of the circuit breaker is caused by its own work, the site should be kept And immediately notify the operation and maintenance personnel for timely processing.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 40091-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40091-2021

$210.00