Scope

GB/T 39764-2021 is the English-translated version of 软体家具中挥发性有机化合物 现场快速检测方法.

GB/T 39764-2021 is the Chinese on-site rapid method for measuring the volatile organic compounds released by upholstered furniture. It gives the terms and definitions, the principle, the equipment, the reagents and materials, the test procedure and the treatment of the test data.

It applies to the on-site rapid detection of VOCs from upholstered furniture, the check made in a shop or a home rather than in a chamber. Furniture makers, inspection bodies and indoor air consultants use it. Issued on 9 March 2021, it has applied since 1 October 2021.

Found what you need?

Document preview — GB/T 39764-2021

National Standard of the People's Republic of China

ICS
97.140
Classification
Y 80

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions4
  • 4 Principle5
  • 5 Equipment5
  • 6 Reagents and materials8
  • 7 Test procedure8
  • 8 Test data11

1 Scope

This document specifies the terms and definitions, principle, equipment, reagents and materials, test procedure, and test data of the on-site and rapid detection method for volatile organic compounds from upholstered furniture.

This document is applicable to on-site and rapid detection of volatile organic compounds from upholstered furniture such as sofas, mattresses, and soft beds with flat surfaces.

2 Normative references

The contents of the following documents, through normative references in this text, constitute indispensable provisions of this document. Among them, for dated references, only the edition corresponding to that date applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 18204.2-2014 Examination methods for public places - Part 2: Chemical pollutants

GB/T 39763 Technical requirements for on-site and rapid collection equipment of volatile organic compounds from furniture

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Volatile organic compounds from upholstered furniture

Volatile organic compounds released from the tested surface of upholstered furniture and tested by on-site and rapid detection method.

3.2 Background clean

The background clean can be performed by either internal circulation (7.3.2) or nitrogen purging mode (7.3.3).

7 Test procedure

7.3.2 Internal circulation

7.3.2.1 Adjust the three-way valve (position 6 in Figure 1) to the upper passage position.

7.3.2.2 Set the flow rate of the gas pump (position 3 in Figure 1) to 600 mL/min. Set the running time to 30 min.

7.3.2.3 Start the gas pump (position 3 in Figure 1). The air in the entire device generates circulating power; so that the air in the collector, at a flow rate of 600 mL/min, passes through the mixing filter pipe (position 7 in Figure 1) and then returns to the collector. The volatile organic compounds in the ambient background air are absorbed by the mixing filter pipe (position 7 in Figure 1), to form clean air circulation to replace the air in the collector.

7.3.3 Nitrogen purging

Connect the nitrogen source (position 13 in Figure 1) to the intake port (position 1 in Figure 1) on the left side of the mask body. Open the top exhaust port (position 2 in Figure 1) to exhaust nitrogen. Turn on the nitrogen source, to purge the air in the mark body at a flow rate of 1 L/min, for no less than 18 min; replace the air in the mask body with nitrogen. After purging, immediately turn off the nitrogen source and the top exhaust port.

7.4 Cyclic enrichment

7.4.1 After the background clean, adjust the three-way valve (position 6 in

Figure 1) to the lower passage position.

7.4.2 Start the thermostat (position 9 in Figure 1) to control the heating temperature to (40±2)°C. Start the gas pump (position 3 in Figure 1). The temperature of the air entering at the entrance (position 10 in Figure 1) of the test mask body shall be (36±2)°C. When the air temperature at the entrance does not meet the requirement of (36±2)°C, the thermostat (position 9 in Figure

1) shall be adjusted. The VOCs released by the sample are enriched in the collector. The circulating gas flow is 600 mL/min. The enrichment time is 30 min.

7.5 Sampling and rapid VOCs analysis

7.5.1 General

The total amount of gas analyzed in each sampling shall not be greater than 80% of the volume of the mask body.

If the amount of gas collected for sampling analysis is greater than 10% of the volume of the mask body, when the test is continued, 7.4.2 cyclic enrichment shall be repeated before sampling.

Under the condition of meeting the detection requirements, the collection parameters can be set according to the instructions for use of the instrument.

7.5.2 Rapid formaldehyde analysis

After the end of the cyclic enrichment, within 30 s, turn on the gas circuit switch (position 5 in Figure 1); connect the rapid VOCs analyzer (position 15 in Figure

1) with the on-site and rapid collection equipment. Collect the gas in the mask body for analysis. The reading displayed on the rapid formaldehyde analyzer is the formaldehyde concentration value. The measured value of volume fraction shall, according to formula (15) in 7.4.4.1 of GB/T 18204.2-2014, be converted into mass concentration.

7.5.3 Rapid analysis for other aldoketone VOCs

After the end of the cyclic enrichment, within 30 s, turn on the gas circuit switch (position 5 in Figure 1); connect the rapid VOCs analyzer (position 15 in Figure

1) with the on-site and rapid collection equipment. At a rate of 100 mL/min, collect the gas in the mask body into the rapid analyzer for other aldoketone VOCs. At the same time of collecting, at the left supply port (position 1 in Figure

1), at the same flow rate, replenish nitrogen (6.2) to the mask body, to maintain the pressure balance in the system. When the sampling is completed, stop replenishing gas. When replenishing gas, at the left supply port (position 1 in

Figure 1), it is possible to connect a supplementary gas bag (6.4) filled with nitrogen. After sampling, the connection shall be disconnected immediately.

The sampling time and gas replenishing time are both 10 min.

After the analysis is completed, the reading displayed on the rapid VOCs analyzer is the concentration value of other aldoketone VOCs.

7.5.4 Rapid analysis for non-aldoketone VOCs

After the end of the cyclic enrichment, within 30 s, turn on the gas circuit switch (position 5 in Figure 1); connect the rapid VOCs analyzer (position 15 in Figure

1) with the on-site and rapid collection equipment. At a rate of 100 mL/min, collect the gas in the mask body into the rapid analyzer for non-aldoketone VOCs. At the same time of collecting, at the left supply port (position 1 in Figure

1), at the same flow rate, replenish nitrogen (6.2) to the mask body, to maintain the pressure balance in the system. When the sampling is completed, stop replenishing gas. When replenishing gas, at the left supply port (position 1 in

Figure 1), it is possible to connect a gas bag (6.4) filled with nitrogen. After sampling, the connection shall be disconnected immediately. The sampling time

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 39764-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39764-2021

$155.00