Valid

GB/T 39672-2020Mancozeb (English PDF)

代森锰锌

Preview PDF

This is a limited preview

Buy now to download the full PDF (22 pages)

Need quotation for your management?

Get a formal quotation for GB/T 39672-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 14, 2020

Implementation date

July 1, 2021

Scope

GB/T 39672-2020 is the English-translated version of 代森锰锌.

GB/T 39672-2020 is the Chinese standard "Mancozeb". Its scope clause reads: This standard specifies the technical requirements, test methods, acceptance and quality assurance period, as well as marks and standards for mancozeb technical and wettable powders.

Sign, packaging, storage and transportation. This standard applies to the quality control of mancozeb technical and mancozeb wettable powder products. Note. See Appendix A for other names, structural formulas and basic physical and chemical parameters of mancozeb and ethylene thiourea. Its clauses include technical requirements; test method.

Found what you need?

Document preview — GB/T 39672-2020

National Standard of the People's Republic of China

ICS
65.100.30
Classification
G 25
Replacing
GB/T 20699-2006

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 3.2 of the.2006 edition);
  • 3.2);

1 Scope

This standard specifies the technical requirements, test methods, acceptance and quality assurance period, as well as marks and standards for mancozeb technical and wettable powders.

Sign, packaging, storage and transportation.

This standard applies to the quality control of mancozeb technical and mancozeb wettable powder products.

Note. See Appendix A for other names, structural formulas and basic physical and chemical parameters of mancozeb and ethylene thiourea.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article

Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB/T 601 Preparation of Standard Titration Solution for Chemical Reagents

Preparation of preparations and products used in GB/T 603 chemical reagent test method

GB/T 1600-2001 Pesticide moisture determination method

GB/T 1601 Method for determination of pesticide pH

GB/T 1604 Acceptance Rules for Commodity Pesticides

GB/T 1605-2001 Commercial pesticide sampling method

GB 3796 General Rules for Pesticide Packaging

GB/T 5451 Test method for wettability of pesticide wettable powder

GB/T 6682-2008 Analysis laboratory water specifications and test methods

GB/T 8170-2008 Numerical rounding rules and the expression and determination of limit values

GB/T 14825-2006 Determination method of pesticide suspension rate

GB/T 16150-1995 Determination of the fineness of pesticide powders and wettable powders

GB/T 19136-2003 Method for determination of thermal storage stability of pesticides

GB/T 28137 Determination method for persistent foaming of pesticides

3 Technical requirements

3.1 Appearance

Mancozeb original drug should be light yellow or grayish yellow powder.

Mancozeb wettable powder should be uniform and loose powder without lumps.

3.2 Technical indicators

The control project indicators of mancozeb technical materials should meet the requirements of Table 1, and the control project indicators of mancozeb wettable powder should meet the requirements of Table 2.

4 Test method

Warning---Personnel using this standard should have practical experience in laboratory work. This standard does not point out all safety issues. use

It is the responsibility of the individual to take appropriate safety and health measures and to ensure compliance with relevant national laws and regulations.

4.1 General rules

The reagents and water used in this standard refer to analytical reagents and the third level specified in GB/T 6682-2008 unless other requirements are indicated.

water. The judgment of the inspection result shall be carried out according to 4.3.3 of GB/T 8170-2008.

4.2 Sampling

The original medicine is carried out according to 5.3.1 of GB/T 1605-2001, and the wettable powder is carried out according to 5.3.3 of GB/T 1605-2001.Use random

The number table method determines the number of packages sampled. Final sampling volume. Mancozeb technical drug should be no less than 100g, mancozeb wettable powder should be no less

4.3 Identification test

4.3.1 Liquid chromatography

This identification test can be carried out simultaneously with the determination of mancozeb mass fraction. Under the same chromatographic operating conditions, the main color in the sample solution

The relative difference between the retention time of the peak and the retention time of the mancozeb derivative in the standard solution should be no more than 1.5%.

4.3.2 Dithizone colorimetry
4.3.2.1 Reagents and instruments
4.3.2.1.1

Trichloromethane.

4.3.2.1.2

Glacial acetic acid.

4.3.2.1.3 Dithizone

known mass fraction w dithizone >=99.0%.

4.3.2.1.4 Dithizone trichloromethane solution

mass fraction w dithizone = 1g/kg.

4.3.2.1.5 Dithizone glacial acetic acid solution

Take 2 mL of dithizone chloroform solution, add 0.25 mL of glacial acetic acid, and dilute with chloroform to

10mL, shake well.

4.3.2.1.6

Qualitative filter paper.

4.3.2.1.7

Capillary.

4.3.2.2 Measurement procedure

Test 1.Weigh about 0.5g of the sample, add 2mL~3mL of distilled water, stir to make the sample evenly dispersed. Prepared with capillary

The sample is dripped onto the filter paper, dripped into powder dots, placed to dry naturally.

Use a capillary to suck the dithizone glacial acetic acid solution and drop it onto the powder spot. The center of the powder spot appears yellow and the surroundings appear pink.

Test 2.Weigh about 0.5g of the sample, add 2mL~3mL chloroform, stir to make the sample evenly dispersed. Prepare the

The good sample is dripped on the filter paper, dripped into powder dots, and placed to dry naturally.

Use a capillary to suck the dithizone trichloromethane solution and drop it onto the powder spot. The center of the powder spot appears yellow, and then quickly turns to bright purple.

If the test results satisfy both test one and test two, it can be confirmed that the sample is mancozeb.

4.4 Determination of appearance

Determined by visual inspection.

4.5 Determination of the mass fraction of mancozeb

4.5.1 Method summary

The manganese ion and zinc ion in mancozeb and the chelating agent disodium ethylenediaminetetraethanol (EDTA) form complexes and water under alkaline conditions

Soluble ethylene dithiocarbamate anion (referred to as mancozeb derivative). The substance uses reversed-phase high-performance liquid at a wavelength of 282nm

Chromatographic separation and determination. The determination of mancozeb mass fraction can also be done by chemical methods. For specific analysis methods, see Appendix B in B.1.

4.5.2 Reagents and solutions
4.5.2.1 Methanol

chromatographically pure.

4.5.2.2

Tetrabutylammonium hydrogen sulfate.

4.5.2.3

Disodium ethylenediaminetetraacetic acid.

4.5.2.4

Disodium hydrogen phosphate.

4.5.2.5

Sodium sulfite.

4.5.2.6

Sodium hydroxide.

4.5.2.7 Sodium hydroxide solution

mass concentration rhoNaOH=50g/L.

4.5.2.8 Water

Freshly steamed twice distilled water.

4.5.2.9 Mancozeb standard sample

known mass fraction w>=86.0%.

4.5.2.10

Buffer solution A. Weigh 3.40g of tetrabutylammonium hydrogen sulfate, 3.72g of disodium edetate, and 1.42g of disodium hydrogen phosphate, respectively.

Dissolve in 1000mL water, adjust pH=10 with sodium hydroxide solution, mix well with ultrasound, filter with filter membrane, and set aside.

4.5.2.11 Buffer solution B

Weigh 7.44g disodium ethylenediaminetetraacetic acid and 1.42g disodium hydrogen phosphate, dissolve them in 1000mL water, and use

Adjust pH to 11 with sodium hydroxide solution, then add 3g of sodium sulfite, dissolve and mix well and place in the refrigerator (at least 50min) for use.

4.5.3 Apparatus
4.5.3.1 High performance liquid chromatograph

with variable wavelength ultraviolet detector.

4.5.3.2

Chromatographic data processor or chromatographic workstation.

4.5.3.3 Chromatographic column

150mm×4.6mm (inner diameter) stainless steel column with C18 and 5µm packing (or a chromatographic column with equivalent effect).

4.5.3.4 Filter

The pore size of the filter membrane is about 0.45µm.

4.5.3.5 Micro-injector

50µL.

4.5.3.6 Quantitative sample injection tube

5µL.

4.5.3.7

Ultrasonic cleaner.

4.5.4 HPLC operating conditions
4.5.4.1 Mobile phase

volume ratio psi methanol. buffer solution A = 30.70, filtered through a membrane, and degassed.

4.5.4.2 Flow rate

1.0mL/min.

4.5.4.3 Column temperature

room temperature (temperature change should not exceed 2°C).

4.5.4.4 Detection wavelength

282nm.

4.5.4.5 Injection volume

5µL.

4.5.4.6 Retention time

Mancozeb derivative is about 7.5min.

4.5.4.7

The above operating parameters are typical, and the given operating parameters can be adjusted appropriately according to the characteristics of different instruments in order to obtain the best effect. Typical derivatized mancozeb technical and wettable powder high performance liquid chromatograms are shown in Figure 1 and Figure 2, respectively.

4.5.5 Measurement procedure
4.5.5.1 Preparation of standard solution

Weigh 0.04g (accurate to 0.0001g) mancozeb standard sample in a 100mL volumetric flask, add 80mL buffer solution B under shaking.

In the ultrasonic (add ice cubes in the ultrasonic oscillator, so that the ultrasonic temperature is not higher than 20 °C), oscillate for 5 minutes, and dilute to the mark with buffer solution B

Shake well. Use a pipette to transfer 5 mL of the above solution into a 50 mL volumetric flask, dilute to the mark with buffer solution B, shake well, and filter with a filter membrane spare. (The solution is stored at low temperature, the temperature should not be higher than 20 °C).

4.5.5.2 Preparation of sample solution

Weigh a sample containing 0.035g (accurate to 0.0001g) of mancozeb into a 100mL volumetric flask, add 80mL buffer solution under shaking

Liquid B. In the ultrasonic (add ice cubes in the ultrasonic oscillator, so that the ultrasonic temperature is not higher than 20 °C), oscillate for 5 minutes, and dilute to the volume with buffer solution B

Scale and shake well. Use a pipette to transfer 5 mL of the above solution into a 50 mL volumetric flask, dilute to the mark with buffer solution B, shake well, and use a filter membrane

Filter for use. (The solution is stored at low temperature, the temperature should not be higher than 20°C)

4.5.5.3 Determination

Under the above operating conditions, after the instrument is stable, continuously inject several needles of the standard solution until the peak area of the adjacent two needles of mancozeb derivative

After the relative change is less than 1.5%, the determination is carried out in the order of standard solution, sample solution, sample solution, and standard solution.

4.5.6 Calculation

The measured peak areas of mancozeb derivatives in the two needles of the sample solution and the two needles of the standard solution before and after the sample were averaged respectively. Sample

The mass fraction of mancozeb is calculated according to formula (1).

4.5.7 Tolerance

The difference between the results of two parallel determinations. Mancozeb technical drug should not exceed 1.5%, 80% mancozeb wettable powder should not exceed 1.2%,

70% mancozeb wettable powder should not exceed 1.0%, 50% mancozeb wettable powder should not exceed 0.7%, take their arithmetic average respectively

The value is used as the measurement result.

4.6 Determination of manganese and zinc mass fraction

4.6.1 Method summary

The sample is dissolved in the disodium ethylenediaminetetraacetic acid solution and introduced into the atomic absorption spectrometer. After the flame is atomized, the characteristic absorption of manganese (zinc) is measured

The absorbance under the spectrum was quantified by the working curve measured by manganese and zinc standard solutions. The determination of manganese and zinc mass fractions can also use chemical methods.

For the analysis method, see B.2 and B.3.

4.6.2 Reagents and solutions
4.6.2.1

Disodium ethylenediaminetetraacetic acid.

4.6.2.2 Disodium ethylenediaminetetraacetic acid solution

Weigh 7.44g disodium ethylenediaminetetraacetic acid and dissolve it in 1000mL water.

4.6.2.3 Manganese standard solution

mass concentration rhoMn=1000µg/mL. Keep refrigerated.

4.6.2.4 Zinc standard solution

mass concentration rhoZn=1000µg/mL. Keep refrigerated.

4.6.3 Apparatus
4.6.3.1

Atomic absorption spectrometer.

4.6.3.2

Manganese hollow cathode lamp.

4.6.3.3

Zinc hollow cathode lamp.

4.6.4 Preparation of sample solution

Weigh a sample containing 0.045g (accurate to 0.0001g) mancozeb into a 100mL volumetric flask, add 80mL ethylenediaminetetraacetic acid

The disodium solution was ultrasonically oscillated for 5 minutes, and the volume was adjusted to the mark with disodium ethylenediaminetetraacetic acid solution, and then shaken. Use a pipette to pipette the above solution

0.5mL in a 50mL volumetric flask, dilute to the mark with disodium ethylenediaminetetraacetic acid solution, shake.

At the same time, prepare a blank solution without mancozeb sample as the reference solution according to the above method.

4.6.5 Determination of standard curve
4.6.5.1 Preparation of standard stock solutions

Manganese standard stock solution. mass concentration rhoMn=20µg/mL. Pipette 0.5mL manganese standard solution into a 25mL volumetric flask, dilute with water

Release to the mark and shake well.

Zinc standard stock solution. mass concentration rhoZn=10µg/mL. Pipette 0.5mL zinc standard solution into a 50mL volumetric flask, dilute with water

Release to the mark and shake well.

4.6.5.2 Preparation of standard solution
4.6.5.2.1 Preparation of manganese standard solution

Pipette 0mL, 0.2mL, 0.5mL, 1.0mL, 2.0mL, 3.0mL of manganese standard stock solution into a 50mL volumetric flask.

Dilute to the mark with water and shake well.

4.6.5.2.2 Preparation of zinc standard solution

Pipette 0mL, 0.5mL, 0.8mL, 1.5mL, 3.0mL, 5.0mL of the zinc standard stock solution into a 50mL volumetric flask.

Dilute to the mark with water and shake well.

4.6.5.3 Determination of the standard curve

After the instrument is stabilized and the zero point is adjusted, the standard solution without manganese (zinc) is used as the reference solution, and the measurement is performed at a wavelength of 279.5nm (213.9nm).

Determine the absorbance of each standard solution of manganese (zinc).

Take the concentration of the standard solution as the abscissa and the corresponding absorbance as the ordinate to draw the standard curve.

4.6.6 Determination

Under the same conditions as the standard curve determination, measure the absorbance of the sample solution and find out the corresponding concentration on the working curve.

4.6.7 Calculation

Find the concentration of manganese (zinc) on the standard curve, and calculate the mass fraction of manganese (zinc) in the sample according to formula (2).

4.6.8 Tolerance

The relative deviation of the results of two parallel determinations. manganese should not be greater than 5%, zinc should not be greater than 10%, and the arithmetic average of them should be taken as the determination.

result.

4.7 Determination of arsenic mass fraction

4.7.1 Method summary

After the sample is digested with acid, it is prepared into an aqueous solution, and the content of arsenic in the solution is measured with an atomic fluorescence spectrometer. The limit of quantification is

0.01µg/g. The determination of arsenic mass fraction can also use chemical methods, see B.4 for specific operations.

4.7.2 Reagents and solutions
4.7.2.1 Nitric acid solution

solution concentration cHNO3=0.2mol/L.

4.7.2.2

Perchloric acid.

4.7.2.3 Hydrochloric acid

mass fraction wHCl=36.0%~38.0%.

4.7.2.4 Mixed acid

volume ratio psiHClO4.HNO3=1.3.

4.7.2.5 Hydrochloric acid solution

volume ratio psiHCl.H2O=1.9.

4.7.2.6

Hydrogen peroxide.

4.7.2.7

Ascorbic acid.

4.7.2.8

Thiourea.

4.7.2.9 Ascorbic acid-thiourea mixed solution

10g ascorbic acid and 10g thiourea are dissolved in 100mL water.

4.7.2.10 Arsenic standard solution

mass concentration rhoAs=1.0mg/mL. Sealed and refrigerated.

4.7.2.11

Potassium borohydride.

4.7.2.12

Sodium hydroxide.

4.7.2.13

High purity argon gas.

4.7.3 Apparatus
4.7.3.1

Atomic fluorescence spectrometer.

4.7.3.2

Electric heating plate.

4.7.4 Operating conditions of atomic fluorescence spectroscopy
4.7.4.1 Negative high voltage of photomultiplier tube

260V.

4.7.4.2 Lamp current

80mA.

4.7.4.3 Carrier gas flow

600mL/min.

4.7.4.4 Auxiliary gas flow

800mL/min.

4.7.4.5 Pump speed

100r/min.

4.7.4.6 Integration time

5s.

4.7.5 Measurement procedure
4.7.5.1 Preparation of standard solution
4.7.5.1.1 Preparation of arsenic standard stock solution

Use a pipette to draw 1mL of arsenic standard solution in a 1000mL volumetric flask, and dilute with nitric acid solution. Prepared into 1mg/L standard storage

Prepare solution. It can be stored in the refrigerator for 1 month.

4.7.5.1.2 Preparation of arsenic standard solution

Prepare 6 levels of standard solutions with different concentrations in the range of 0µg/L~10µg/L.

Draw 0mL, 0.1mL, 0.2mL, 0.3mL, 0.4mL, 0.5mL of 1mg/L arsenic standard stock solution to 50mL volume respectively

In the bottle, add 25mL of hydrochloric acid solution, then add 5mL of ascorbic acid-thiourea mixture, and dilute to 50mL with water. Place at room temperature for 2h the above.

4.7.5.2 Preparation of sample solution
4.7.5.2.1 Wet digestion

Weigh 0.5g of the sample (accurate to 0.0001g), place it in a 150mL conical flask, add 10mL nitric acid, and place the conical flask on the electric heating plate

Slowly heat on the upper surface until the yellow smoke basically disappears; after a little cold, add 10 mL of mixed acid, and heat it on the heater until the sample is completely digested.

To a transparent solution (sometimes it is necessary to add mixed acid as appropriate); add 10mL of water after a little cold, heat to boiling and emit white smoke, and keep it for a few minutes to drive off

The remaining mixed acid, then cooled to room temperature, to prepare the sample solution.

4.7.5.2.2 Preparation of sample solution

Transfer all the prepared digestion solution to a 50mL volumetric flask (if the solution appears turbidity, precipitation or mechanical impurities, be sure to pass

Filter), and dilute to 50 mL with water.

When the mass fraction of arsenic in the sample is less than 2.5µg/g, take 20mL of the digestion solution after constant volume into a 50mL volumetric flask, and add ascorbic acid

Serum acid-thiourea mixture 5mL, then dilute to 50mL with hydrochloric acid solution, and place at room temperature for more than 2h.

When the mass fraction of arsenic in the sample is 2.5µg/g~10µg/g, take 5mL of the digestion solution after constant volume into a 50mL volumetric flask, and add

5mL of ascorbic acid-thiourea mixture, then add 25mL of hydrochloric acid solution, and dilute to 50mL with water, and place at room temperature for more than 2h.

When the mass fraction of arsenic in the sample is greater than 10 µg/g, take 0.5 mL of the digestion solution after constant volume into a 50 mL volumetric flask, and add ascorbic acid

5mL of blood acid-thiourea mixture, then add 25mL of hydrochloric acid solution, and dilute to 50mL with water, and place at room temperature for more than 2h.

At the same time, prepare a blank solution without adding samples in the same way.

4.7.5.3 Determination

After the atomic fluorescence spectrometer is stable, the fluorescence intensity of each standard solution is measured in turn, and a standard curve is drawn. Then determine the blank melt

Fluorescence intensity of liquid and sample solution.

4.7.6 Calculation

The mass fraction of arsenic in the sample is calculated according to formula (3).

4.7.7 Tolerance

The relative deviation of the two parallel determination results should be no more than 10%, and the arithmetic mean value shall be taken as the determination result.

4.8 Determination of Ethylene Thiourea (ETU) Mass Fraction

4.8.1 Method summary

The sample is dissolved in methanol solution, methanol and water are used as the mobile phase, and a stainless steel column with C18 packing and a UV detector are used for the sample

ETU was separated by reversed-phase high performance liquid chromatography and quantified by external standard method. (The detection limit of this method is 0.0004%, and the limit of quantification is 0.001%)

4.8.2 Reagents and solutions
4.8.2.1 Methanol

chromatographically pure.

4.8.2.2 Methanol solution

volume ratio psi methanol. water = 40.60.

4.8.2.3 Water

ultrapure water or freshly steamed and double distilled water.

4.8.2.4 ETU standard sample

the known mass fraction wETU>=98.5%.

4.8.3 Apparatus
4.8.3.1 High performance liquid chromatograph

with variable wavelength ultraviolet detector.

4.8.3.2

Chromatographic data processor or chromatographic workstation.

4.8.3.3 Chromatographic column

250mm×4.6mm (inner diameter) stainless steel column with C18 and 5µm filler (or a chromatographic column with equivalent effect).

4.8.3.4 Filter

The pore size of the filter membrane is about 0.45µm.

4.8.3.5 Micro-injector

50µL.

4.8.3.6 Quantitative sample injection tube

5µL.

4.8.3.7

Ultrasonic cleaner.

4.8.4 HPLC operating conditions
4.8.4.1 Mobile phase

volume ratio psi methanol. water = 7.93, filtered through a membrane and degassed.

4.8.4.2 Flow rate

1.0mL/min.

4.8.4.3 Column temperature

room temperature (temperature change should not exceed 2°C).

4.8.4.4 Detection wavelength

233nm.

4.8.4.5 Injection volume

5µL.

4.8.4.6 Retention time

4.4min.

4.8.4.7

The above operating parameters are typical, and the given operating parameters can be adjusted appropriately according to the characteristics of different instruments in order to obtain the best effect. The typical high performance liquid chromatograms of mancozeb technical and wettable powder for ETU determination are shown in Figure 3 and Figure 4, respectively.

Figure 4 High performance liquid chromatogram in the determination of ETU in mancozeb wettable powder

4.8.5 Measurement procedure
4.8.5.1 Preparation of standard solution

Weigh 0.01g (accurate to 0.00001g) ETU standard sample into a 50mL volumetric flask, add 40mL methanol solution to ultrasonic vibration

3min, cool to room temperature, dilute to volume with methanol solution, shake well. Use a pipette to pipette 1mL of the above solution into a 25mL volumetric flask,

Dilute to the mark with methanol solution and shake well.

4.8.5.2 Preparation of sample solution

Weigh 0.2g (accurate to 0.0001g) mancozeb sample into a 50mL volumetric flask, add 40mL methanol solution to ultrasonic vibration

3min, cool to room temperature, dilute to volume with methanol solution, shake well.

4.8.5.3 Determination

Under the above operating conditions, after the instrument is stable, continuously inject several needles of standard solution until the ETU peak area of the two adjacent needles changes relatively

After less than 10%, the measurement is carried out in the order of standard solution, sample solution, sample solution, and standard solution.

4.8.6 Calculation

Average the measured ETU peak areas of the two needles of the sample solution and the two needles of the standard solution before and after the sample. ETU in the sample

4.8.7 Tolerance

The relative deviation of the two parallel determination res...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.

Similar standards

Editions of GB/T 39672

EditionTitleRevisionStatus
GB/T 39672-2020Mancozebcurrent editionCurrent
GB/T 20699-2006Mancozebprevious editionSuperseded

This page sells the current edition, GB/T 39672-2020. Earlier editions are listed for reference only.

How to Download GB/T 39672-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
22 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39672-2020

$390.00