Valid

GB/T 3884.19-2017Methods for chemical analysis of copper concentrates - Part 19: Determination of thallium content - Inductively coupled plasma mass spectrometry (English PDF)

铜精矿化学分析方法 第19部分:铊量的测定 电感耦合等离子体质谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 3884.19-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

September 29, 2017

Implementation date

April 1, 2018

Scope

GB/T 3884.19-2017 is the English-translated version of 铜精矿化学分析方法 第19部分:铊量的测定 电感耦合等离子体质谱法.

GB/T 3884.19-2017 is the Chinese standard "Methods for chemical analysis of copper concentrates - Part 19: Determination of thallium content - Inductively coupled plasma mass spectrometry".

Its scope clause reads: GB/T 3884 provisions of this part of the determination of copper concentrate in the amount of thallium. This section applies to the determination of copper concentrate in the amount of thallium.

Measuring range. 0.05µg/g ~ 25.00µg/g. Its clauses include method summary; reagent; instruments.

Found what you need?

Document preview — GB/T 3884.19-2017

National Standard of the People's Republic of China

ICS
77.120.30
Classification
H 13

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 method summary
  • 3 reagent
  • 4 instruments

1 Scope

GB/T 3884 provisions of this part of the determination of copper concentrate in the amount of thallium.

This section applies to the determination of copper concentrate in the amount of thallium. Measuring range. 0.05µg/g ~ 25.00µg/g.

2 method summary

The samples were decomposed by hydrochloric acid, nitric acid, hydrofluoric acid and perchloric acid. Iridium was used as the internal standard and dilute aqua regia as the medium. Inductively coupled plasma mass spectrometry

Direct determination of the amount of thallium.

3 reagent

Unless otherwise specified, only reagents identified as superior grade pure are used in the analysis; the water used is primary.

3.1

Hydrochloric acid (p = 1.19 g/mL).

3.2

Nitric acid (p = 1.42 g/mL).

Hydrofluoric acid (rho = 1.13 g/mL).

3.4

Perchloric acid (rho = 1.68g/mL).

3.5 hydrochloric acid mixed acid (3

1).

Nitric acid (1 1).

3.7

Thallium standard stock solution Weigh 0.2795g thallium trioxide (wTl2O3 >= 99.99%) placed in a.200mL beaker, covered with a watch glass,

Slowly add 25mL nitric acid (3.6) dissolved, get rid of nitrogen oxides, remove the cooling to room temperature, wash the watch glass and the wall with water, into

250mL volumetric flask, diluted with water to the mark, mix well. 1mL of this solution contains 1mg thallium.

3.8

thallium standard solution A. Pipette Thallium standard stock solution (3.7), by stepwise dilution method, adding 3mL nitric acid (3.2), diluted with water

To the mark, mix well. The final solution 1 mL contains 1 µg of thallium.

3.9 thallium standard solution B

Pipette thallium standard solution A (3.8), by gradual dilution, add 3mL of nitric acid (3.2), diluted with water to

Scale, mix well. The final solution 1 mL contains 10 ng thallium.

3.10

iridium standard stock solution Weigh 0.1000g iridium powder (wIr >= 99.99%), placed in 50mL glass tube, was added 8mL hydrochloric acid (3.1), 2mL hydrogen peroxide, sealing tube. Dissolved at 150 °C 48h, cooling, open tube. Pipette the test solution into 100mL volumetric flask,

Add 10mL hydrochloric acid (3.1), diluted with water to the mark, mix well. 1 mL of this solution contains 1 mg iridium.

3.11 iridium standard solution

Draw iridium standard stock solution (3.10), by gradual dilution, adding 3mL of nitric acid (3.2), diluted with water

To the mark, mix well. The final solution 1 mL contains 10 ng iridium.

3.12

Argon (wAr >= 99.99%).

4 instruments

Inductively Coupled Plasma Mass Spectrometry.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 3884.19-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 3884.19-2017

$85.00