Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

August 30, 2019

Implementation date

July 1, 2020

Scope

GB/T 37883-2019 is the English-translated version of 水处理剂中铬、镉、铅、砷含量的测定 电感耦合等离子体发射光谱(ICP-OES)法.

GB/T 37883-2019 is the Chinese standard "Determination of chromium, cadmium, lead and arsenic in water treatment chemicals—Inductively coupled plasma atomic emission spectrometry".

Its scope clause reads: This standard specifies the method for determining the content of chromium, cadmium, lead and arsenic in water treatment agents--inductively coupled plasma atomic emission spectrometry.

This standard applies to water treatment agent chromium content 0.00025% ~ 0.01%, cadmium content 0.00025% ~ 0.01%, lead content 0.00025%~0.01%, arsenic content 0.00025%~0.01% range determination. Its clauses include method summary; reagents or materials.

Found what you need?

Document preview — GB/T 37883-2019

National Standard of the People's Republic of China

ICS
71.040.40
Classification
G 76

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 method summary
  • 4 reagents or materials

1 Scope

This standard specifies the method for determining the content of chromium, cadmium, lead and arsenic in water treatment agents--inductively coupled plasma atomic emission spectrometry.

This standard applies to water treatment agent chromium content 0.00025% ~ 0.01%, cadmium content 0.00025% ~ 0.01%, lead content

0.00025%~0.01%, arsenic content 0.00025%~0.01% range determination.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article.

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

Preparation of standard solution for GB/T 602 chemical reagent impurity determination

GB/T 6682 Analytical laboratory water specifications and test methods

3 method summary

The sample is atomized into a plasma emission spectrometer and then introduced into the plasma torch by argon gas. Each measured element is in the plasma

The torch is gasified, ionized, excited and emits characteristic lines, and the intensity of the characteristic line is detected by the detector. Within a certain concentration range,

The concentration of the measured element is proportional to the intensity of its characteristic line, thereby determining the content of the element to be tested in the sample. Use external standard according to the characteristics of the sample

The method or standard addition method is used for quantification to determine the content of chromium, cadmium, lead and arsenic in the sample.

4 reagents or materials

Caution - The strong acid used in this standard is corrosive and should be avoided when inhaled or in contact with the skin. Splash on the body should be used immediately

Rinse with water and seek medical attention if it is severe.

4.1

Reagents and water used in this standard, unless otherwise specified, should be used with superior grade reagents and secondary water in accordance with GB/T 6682.

4.2

Standard solution of impurities required in the test Prepare or select the commercially available standard solution according to the provisions of GB/T 602.

4.3

Sulfuric acid.

4.4

Nitric acid.

4.5 Nitric acid solution

1 99.

4.6 Chromium standard stock solution

1000mg/L.

4.7 Chromium standard solution

100mg/L. Pipette 10 mL of chromium standard stock solution, place in a 100 mL volumetric flask, dissolve with nitric acid

Dilute the solution to the mark and shake well. Or according to GB/T 602.

4.8 Cadmium standard stock solution

1000mg/L.

4.9 Cadmium standard solution

100mg/L. Pipette 10 mL of cadmium standard stock solution into a 100 mL volumetric flask and dissolve with nitric acid.

Dilute the solution to the mark and shake well. Or according to GB/T 602.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 37883-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37883-2019

$145.00