GB/T 37879-2019 is the English-translated version of 智能家用电器的智能化技术 空调器的特殊要求.

GB/T 37879-2019 is the Chinese standard "Intelligentization technology for intelligent household appliances - Particular requirements for room air conditions". Its scope clause reads: This standard specifies the terms and definitions, requirements and evaluations of intelligent air conditioner products.

This standard applies to intelligent air conditioners. Its clauses include terms and definitions; requirements. It was issued by the State Administration for Market Regulation on AUGUST 30, 2019 and took effect on MARCH 01, 2020.

Found what you need?

Document preview — GB/T 37879-2019

National Standard of the People's Republic of China

ICS
97.030
Classification
Y 60

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Requirements

1 Scope

This standard specifies the terms and definitions, requirements and evaluations of intelligent air conditioner products.

This standard applies to intelligent air conditioners.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard.

GB/T 28219-2018 General technology requirements for intelligent household appliances

GB/T 33658-2017 Thermal comfort requirements and evaluation for indoor environment

3 Terms and definitions

The terms and definitions defined in GB/T 28219-2018 and the following terms and definition apply to this document.

3.1 Intelligent room air conditioner

The air conditioner which adopts intelligent technology, has the ability to sense, make decisions, execute, learn, and feedback (including the ability to apply learning results); comprehensively utilizes these capabilities to achieve specific functions.

3.2 Intelligent air conditioner's information display and information input

equipment or facilities, including but not limited to the display interface of the air conditioner itself, mobile phone app, TV, computer.

4 Requirements

4.1 Overview

Chapter 4 of GB/T 28219-2018 is applicable except for the following. […]

4.2 Interconnection / interoperability requirements

4.2.1 Intelligent air conditioners can be connected to the industry public service platform; it can be operated by the interactive terminals of other intelligent home appliance manufacturers; it can interact with other intelligent home appliances and intelligent home products. The functions of the intelligent air conditioner that can be operated by other interactive terminals shall include at least the following 4 items:

- Switch on and off;

- Temperature adjustment;

- Mode adjustment;

- Air speed adjustment.

4.2.2 Intelligent air conditioner directly performs data interaction with the industry public service platform. Intelligent air conditioner uses the industry public service platform and the vendor service platform to perform cross-platform data interaction. Intelligent air conditioner uses the vendor service platform and the industry public service platform to perform cross-platform data interaction. Data interaction shall include at least the following 6 items:

- Indoor ambient temperature;

- Air conditioner's setting temperature;

- Air conditioner's ON/OFF status;

- Air conditioner's operating mode;

- Air conditioner's operating wind speed;

- Air conditioner's fault information.

b) If it meets the 4.2.2 compliance requirements of GB/T 28219-2018, it is 100 points; otherwise it is 0 point; recorded as b;

c) If it meets the 4.2.3 convenience requirements of GB/T 28219-2018, it is 100 points; otherwise it is 0 point; recorded as c.

4.3 Intelligent capability

requirements decision system or interactive terminal. The execution ability of intelligent air conditioners include, but are not limited to:

- Start or stop operation at the right time according to the operating strategy;

- Operating at corresponding mode;

- Adjust the room temperature to the required temperature;

- Achieve the required air supply direction and volume;

- Adjust the compressor's operating frequency;

- Adjust the humidity in the room to the required humidity;

- Adjust the air quality in the room except for temperature and humidity to a good condition;

- Adaptively adjust display brightness.

Note: The actions performed by the air conditioner after the user manually controls the air conditioner by a single instruction are not considered as the execution ability of the intelligent air conditioner.

4.3.5 Learning ability

The intelligent air conditioner can continuously collect and sort the air conditioning process and air environment data in a certain period during the work process; it can accumulate a certain amount of data about the user's habits of using the air conditioner, the air environment data, the air conditioner's self-operating data, other third-party data; analyze the accumulated data to form a variety of air-conditioning operating strategies.

Note 1: The intelligent learning ability of intelligent air conditioners can be realized through the cloud or locally.

Note 2: Intelligent learning can be through autonomous learning or human assistant learning.

4.3.6 Feedback ability

The intelligent air conditioner can present the operating status of the air conditioner and the perceived environmental information to the interactive end through a human-computer interaction. The information fed back by the air conditioner can be actively pushed to the interactive terminal or can be queried through the interactive terminal. The information fed back by the air conditioner can be fed back to the interactive terminal. The information fed back by the air conditioner includes, but is not limited to, the setting temperature of the air 2018, it is 100 points; otherwise it is 0 point; recorded as alpha;

b) If meeting the clause 4.1.2 network and security requirements in GB/T 28219-2018, it is 100 points; otherwise it is 0 point; recorded as b;

c) If meeting the clause 4.1.3 electromagnetic compatibility requirements in GB/T 28219-2018, it is 100 points; otherwise it is 0 point; recorded as c.

The full score is 100 points. The actual result = alpha × 40% + b × 30% + c × 30%.

5.2 Evaluation of interconnection / interoperability

The interconnection / interoperability evaluation is divided into the following items:

a) Intelligent air conditioner's data can interact with public service platforms and the data items that meet the requirements of 4.2 are 100 points; intelligent air conditioners can interact with other devices through specific communication means and the data items that meet the requirements of 4.2 are 60 points; otherwise it is 0 point, recorded as alpha;

The full score is 100 points. The actual result = alpha × 40% + b × 30% + c × 30%.

5.3 Evaluation of intelligent capabilities

5.3.1 Perception ability

If it is able to perceive 3 of the 4 items as specified in 4.3.2 and more than 10 different categories of information, it is 100 points. If it is able to perceive 3 of the 4 items as specified in 4.3.2 and 7 ~ 10 different categories of information, it is 80 points. If it is able to perceive 2 of the 4 items as specified in 4.3.2 and 6 ~ 8 different categories of information, it is 60 points. If the perceived information is less than 2 items and less than 5 categories, it is 0 point; recorded as alpha.

The full score is 100 points. The actual result = alpha.

5.3.2 Learning ability

The learning ability is divided into the following items:

a) The self-learning is 100 points; the human assistant learning is 60 points; no learning ability is 0 point, recorded as alpha;

The full score is 100 points. The actual result = alpha × 60% + b × 40%.

5.3.5 Feedback ability

The feedback ability is divided into the following items:

a) If it can actively feedback 10 or more information items listed in 4.3.6, it is 100 points; if it can actively feedback 5 ~ 9 information items listed in 4.3.6, it is 80 points; if it can actively feedback 6 and above information items listed in 4.3.6, it is 60 points; if it can only feedback less than 6 information items as listed in 4.3.6 through query, it is 0 point, recorded as alpha;

b) If it can make feedback both from local and from customer end, it is 100 points; if it can only make feedback from the local or customer end, it is 80 points; if there is no feedback from local or customer end, it is 0 point, recorded as b.

The full score is 100 points. The actual result = alpha × 60% + b × 40%.

5.4 Effect evaluation of intelligent functions

5.4.1 Human comfort

According to GB/T 33658-2017, if it is rated 5 stars, it is 100 points; if it is rated 4 stars or 3 stars, it is 80 points; if it is rated 2 stars or 1 star, it is 60 points; if it does not meet the 1 star requirement, it is 0 point, recorded as alpha.

The full score is calculated as 100 points. The actual result = alpha.

5.4.2 Use convenience The use convenience is divided into the following items:

a) If the intelligent air conditioner can be controlled according to the two or more methods mentioned in 4.4.2, it is 100 points; if the intelligent air conditioner can only be controlled according to one of the methods in 4.4.2, it is 80 points; otherwise it is 0 point, recorded as alpha;

b) The intelligent air conditioner has a variety of intelligent functions to reduce human intervention (100%); the intelligent air conditioner has an intelligent function to reduce human intervention (80%). If it only has key and remote control method, it is 0 point, recorded as b.

The full score is calculated as 100 points. The actual result = alpha × 50% + b × 50%.

5.4.3 Energy saving of use

The energy saving of use is divided into the following items: […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 37879-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37879-2019

$115.00