Valid

GB/T 37784-2019In-situ test method for detection of structural risk of the insulating glass (English PDF)

中空玻璃结构安全隐患现场检测方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 37784-2019 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

August 30, 2019

Implementation date

July 1, 2020

Scope

GB/T 37784-2019 is the English-translated version of 中空玻璃结构安全隐患现场检测方法.

GB/T 37784-2019 is an on-site detection method for safety hazards in the structure of insulating glass, worked by the relative deflection method.

Clause 1 states that it specifies the terms and definitions, detection principles, loading equipment setting, detection method, the proximity value calculation for rectangular plate hollow glass, the risk criterion and the test report, that it applies to the detection of structural safety hazards caused by the failure of the permeability seal of architectural insulating glass, and that it does not apply to the on-site inspection of structural safety hazards of insulating glass fitted with a breathing apparatus and a pressure self-balancing device.

Clause 2 on this page carries the terms and definitions rather than normative references, and gives a single definition, printed as closeness, for the measured value being close to the theoretically calculated value of the failure of the insulating glass seal or to the corresponding value of the failure.

Clause 3 sets out the detection principle: a sealed insulating glass unit whose seal and seal permeability have failed shows a significant difference in bearing deformation performance, so a fixed load is applied to one side of the glass, the thickness of the spacer layer at the geometric centre of the directly loaded surface is measured after the load is applied, and the proximity value is used to decide whether the glass presents a structural safety hazard.

Clause 4 describes the loading device, a lever and weight arrangement that applies a vertical concentrated load at the geometric centre of the insulating glass panel, with an elastic loading ball at the top of the adjusted lever whose contact radius with the glass after loading is 5 mm to 15 mm, a suction cup at the bottom of the lever attached to a smooth surface and a weight applied at the end of the lever, and a note allows other loading devices able to apply and display force values to be selected according to the field loading conditions.

The draft on the page stops at the end of clause 4, so the detection method, the proximity value calculation, the risk criterion and the test report announced in clause 1 are not shown.

The standard was proposed by the China Building Materials Federation and is under the jurisdiction of the National Building Glass Standardization Technical Committee (SAC/TC255). It was issued on 2019-08-30 and has applied since 2020-07-01.

Found what you need?

Document preview — GB/T 37784-2019

National Standard of the People's Republic of China

ICS
81.040
Classification
Q 30

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Terms and definitions
  • 3 Detection principle
  • 4 Loading device

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies the terms and definitions, detection principles, loading equipment for detecting the safety hazards of insulating glass structures by the relative deflection method.

Setting, detection method, rectangular plate hollow glass proximity value calculation, risk criterion and test report.

This standard is applicable to the detection of structural safety hazards caused by the failure of permeability seals for architectural insulating glass.

This standard does not apply to on-site inspection of structural safety hazards of insulating glass with breathing apparatus and pressure self-balancing device.

2 Terms and definitions

The following terms and definitions apply to this document.

2.1 Closeness

The measured value is close to the theoretically calculated value of the failure of the insulating glass seal or the corresponding value of the failure.

3 Detection principle

When the sealing of the insulating glass sealing unit fails and the sealing permeability fails, there will be a significant difference in the bearing deformation performance. In hollow glass A fixed load is applied to one side of the glass, and the thickness of the spacer layer at the geometric center of the direct bearing surface after the force of the insulating glass is measured, and according to the proximity value Determine whether there is structural safety hazard in the insulating glass.

4 Loading device

A vertical concentrated load is applied to the geometric center of the insulating glass panel using a lever-weight loading device, as shown in Figure 1. In length The top of the adjusted lever is provided with an elastic loading ball, and the contact radius of the loaded ball and the glass after loading is 5 mm to 15 mm. Lever bottom setting There is a suction cup that is attached to a smooth surface and a weight applied to the end of the lever elastic loading ball.

Note: Depending on the field loading conditions, other loading devices that can apply and display force values can also be selected.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 37784-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37784-2019

$205.00