GB/T 37544-2019Determination of 6 kinds of phenolic antibacterial agent including o-Cymen-5-ol in Cosmetics - High performance liquid chromatography (English PDF)
化妆品中邻伞花烃-5-醇等6种酚类抗菌剂的测定 高效液相色谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 37544-2019 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 4, 2019
Implementation date
January 1, 2020
Scope
GB/T 37544-2019 is the English-translated version of 化妆品中邻伞花烃-5-醇等6种酚类抗菌剂的测定 高效液相色谱法.
GB/T 37544-2019 is the Chinese standard "Determination of 6 kinds of phenolic antibacterial agent including o-Cymen-5-ol in Cosmetics - High performance liquid chromatography".
Its scope clause reads: This standard specifies phenol, p-chloro-m-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol, and pentachlorobenzene in cosmetics.
Principles, methods and reagents of high-performance liquid chromatography for the determination of 6 phenol antibacterial agents, reagents and materials, equipment, test procedures, calculation of results, recovery Rate and precision, tolerance, etc. This standard applies to phenol, p-chloro-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol, and pentachlorobenzene in cosmetics.
Determination of 6 phenol antibacterial agents.
The detection limit and limit of quantitation of the methods of this standard. phenols in water preparations, emulsions, creams, powder cosmetics, p-chloro-m-cresol, o-cymene-5- The method detection limit of alcohol, 4-tert-butylphenol, 2,4,6-trichlorophenol and pentachlorophenol is 2.5mg/kg, and the method limit of quantification is 8.5mg/kg.
The detection limits of phenol, p-chloro-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol and pentachlorophenol in cosmetics are. 5.0mg/kg, the method limit of quantification was 17.0mg/kg.
Its clauses include principle; reagents and materials; equipment; test steps; results calculation; recovery and precision; tolerance.
Found what you need?
Document preview — GB/T 37544-2019
National Standard of the People's Republic of China
- ICS
- 71.100.70
- Classification
- Y 42
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 0.0 80
- 7.0 70
- 10.0 65
- 20.0 65
- 23.0 10
- 30.0 10
- 31.0 80
- 39.0 80
- 6.3 Standard working curve drawing
- 6.4 Sample determination
- 6.5 Blank test
- 7 Results calculation
- 8 Recovery and precision
- 9 tolerance
- Appendix A
- Appendix B
- 1 --- phenol;
1 Scope
This standard specifies phenol, p-chloro-m-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol, and pentachlorobenzene in cosmetics.
Principles, methods and reagents of high-performance liquid chromatography for the determination of 6 phenol antibacterial agents, reagents and materials, equipment, test procedures, calculation of results, recovery
Rate and precision, tolerance, etc.
This standard applies to phenol, p-chloro-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol, and pentachlorobenzene in cosmetics.
Determination of 6 phenol antibacterial agents.
The detection limit and limit of quantitation of the methods of this standard. phenols in water preparations, emulsions, creams, powder cosmetics, p-chloro-m-cresol, o-cymene-5-
The method detection limit of alcohol, 4-tert-butylphenol, 2,4,6-trichlorophenol and pentachlorophenol is 2.5mg/kg, and the method limit of quantification is 8.5mg/kg.
The detection limits of phenol, p-chloro-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol and pentachlorophenol in cosmetics are.
5.0mg/kg, the method limit of quantification was 17.0mg/kg.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
3 Principle
The phenol, p-chloro-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol, and pentachlorophenol in the sample were extracted by the solvent.
After centrifugal filtration, it was determined by high-performance liquid chromatography equipped with a diode array detector. The retention time and spectrum were qualitatively determined by external standard method.
Confirmed by HPLC-MS/MS.
4 Reagents and materials
4.1 Water
Grade I water specified in GB/T 6682.
4.2 Acetonitrile
chromatographically pure.
4.3 Formic acid
chromatographically pure.
4.4 Ammonium acetate
chromatographically pure.
4.5 Acetonitrile aqueous solution
Accurately measure 70mL of acetonitrile (4.2) and 30mL of water.
4.6 Standard material
purity is not less than 98%. Phenol, p-chloro-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol,
Chinese name, INCI name (International Cosmetic Raw Material Name), English name, CAS number, molecular formula, relative molecular weight and
For the chemical structural formula, see Appendix A, Table A.1.
4.7 Mixed standard working solution
Weigh the appropriate amount of standard material (4.6) (accurate to 0.1mg) accurately, and prepare the mass with acetonitrile (4.2)
Standard stock solution with a concentration of.2000 µg/mL (storage at 4 ° C, protected from light, can be stored for 6 months). Accurately pipette each standard stock solution
500.0 µL in a 10 mL volumetric flask, make up to volume with an acetonitrile aqueous solution (4.5), and mix to obtain a mixed standard stock solution (100.0 µg/mL,
4 ° C, protected from light). Accurately remove an appropriate amount of the standard stock solution, and dilute it gradually with an acetonitrile aqueous solution (4.5) to a mass concentration of 0.10 µg/mL,
Series of 0.20 µg/mL, 0.50 µg/mL, 1.00 µg/mL, 2.50 µg/mL, 5.00 µg/mL, 10.0 µg/mL, and 50.0 µg/mL
Mix standard working solution (now equipped with current use).
4.8 Microporous filter
organic filter with a pore size of 0.22µm.
5 Equipment
General laboratory equipment, and the following instruments.
a) High performance liquid chromatography (HPLC) instrument. equipped with a diode array detector;
b) HPLC-triple quadrupole mass spectrometer;
c) Analytical balance. Sensitivity 0.001g and 0.0001g;
d) vortex oscillator;
e) Ultrasonic cleaning instrument. ultrasonic power 250W;
f) Centrifuge. The maximum speed is not less than 4000r/min.
6 Test steps
6.1 Sample processing
6.1.1 Liquid, emulsion, cream, powder cosmetics
Weigh 0.2g of the sample (accurate to 0.001g) into a 15mL stoppered plastic centrifuge tube, add acetonitrile aqueous solution (4.5) to 5.0mL, and vortex
Shake for 2min, sonicate for 10min, centrifuge at 4000r/min for 5min, and take the supernatant through a 0.22µm filter membrane to be determined.
6.1.2 Wax-based cosmetics
Weigh 0.1g of the sample (accurate to 0.001g) into a 15mL stoppered plastic centrifuge tube, add 0.5mL tetrahydrofuran, and vortex until
Dissolve all, then add acetonitrile aqueous solution (4.5) to 5.0mL, vortex for 2min, sonicate for 10min, centrifuge at 4000r/min for 5min,
Take the supernatant through a 0.22 µm filter and wait for the determination.
6.2 Measurement conditions
The HPLC reference conditions are as follows.
a) Chromatographic column. Column for PAHs, 5µm, 250mm × 4.6mm (inner diameter), or equivalent;
b) Mobile phase. acetonitrile-10mmol/L ammonium acetate aqueous solution [adjusted to pH 5.0 with formic acid (4.3)], see Table 1 for gradient elution procedure;
c) Flow rate. 1.2mL/min;
d) Column temperature. 30 °C;
e) Detection wavelength. 280nm;
f) Injection volume. 20 µL.
Table 1 Gradient elution procedure
Time/min 10mmol/L ammonium acetate aqueous solution (pH5.0) /% acetonitrile /%
0.0 80 20
Table 1 (continued)
Time/min 10mmol/L ammonium acetate aqueous solution (pH5.0) /% acetonitrile /%
6.3 Standard working curve drawing
Measure the serial mixed standard working solution (4.7) according to the measurement conditions (6.2), and take the peak area of the chromatographic peak as the ordinate, and the corresponding solvent
The liquid concentration is plotted on the abscissa and a standard working curve is drawn.
The HPLC chromatograms of the six reference materials are shown in Appendix B, Figure B.1.
6.4 Sample determination
Measure the sample solution according to the measurement conditions (6.2). The test substance in the sample solution is qualitatively determined based on the retention time and the spectrum. By sample
The peak area of the solution, the corresponding analyte concentration was found from the standard curve. The response value of the test object in the sample solution should be determined by the instrument.
Within the linear range, the sample solution beyond the linear range needs to be diluted with acetonitrile aqueous solution (4.5) before determination. If necessary, use HPLC Spectrum-mass spectrometry/mass spectrometry for confirmation experiments, see Appendix C.
6.5 Blank test
Except that no sample is added, the measurement is performed according to 6.1 ~ 6.2.
7 Results calculation
Calculate the content of the test substance in the sample according to formula (1).
w = (rho-rho0) × V × 1000 m × 1000 (1)
Where.
w --- the content of each test substance in the sample, the unit is milligram per kilogram (mg/kg);
rho --- mass concentration corresponding to the peak area of each analyte in the sample solution, the unit is micrograms per milliliter (µg/mL)
rho0 --- the mass concentration of each test substance in the blank test, the unit is micrograms per milliliter (µg/mL);
V --- constant volume, unit is milliliter (mL);
m --- sample mass in grams (g).
The calculation result is accurate to one digit after the decimal point.
8 Recovery and precision
In liquid preparations, emulsions, creams, powder cosmetics, phenol, p-chloro-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-tris
Chlorophenol and pentachlorophenol are in the range of 8.5mg/kg ~ 85.0mg/kg, and the recovery rate is between 80% ~ 110%.
The quasi deviation is less than 10%;
Among wax-based cosmetics, phenol, p-chloro-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol, and pentachlorophenol are being added.
When the concentration is 17.0mg/kg ~ 170.0mg/kg, the recovery rate is between 80% ~ 110%, and the relative standard deviation is less than 10%.
9 tolerance
The absolute difference between the two independent determination results obtained under repeatable conditions shall not exceed 10% of the arithmetic mean.
Appendix A (Informative appendix)
Information on 6 phenolic antimicrobial reference materials
Chinese name, INCI name, English name, CAS number, molecular formula, relative molecular mass and chemical structural formula of 6 phenolic antibacterial agents
See Table A.1.
Table A.1 Chinese name, INCI name/English name, CAS number, molecular formula,
Relative molecular mass and chemical structural formula
Chinese name INCI name English name CAS number Molecular formula Relative molecular mass Chemical structural formula
Phenol 108-95-2 C6H5OH 94.1
P-chlorom-cresol p
-chloro-m- cresol
4-chloro- m-cresol
59-50-7 C7H7ClO 142.6
O-cymen-5-ol
4-isopropyl- m-cresol
3228-02-2 C10H14O 150.2
4-tert-butylphenol-
4-tert- butylphenol
98-54-4 C10H14O 150.2
2,4,6-trichlorophenol-
2,4,6-trichlor ophenol
88-06-2 C6H3Cl3O 197.5
Pentachlorophenol-p entachlorop henol
87-86-5 C6HCl5O 266.3
Appendix B (Informative appendix)
High performance liquid chromatography of phenol, p-chloro-m-cresol, o-cymene-5-ol, 4-tert-butylphenol, 2,4,6-trichlorophenol, pentachlorophenol
The high performance liquid chromatograms of the six phenolic antibacterial agents are shown in Figure B.1.
Explanation.
1 --- phenol;
2--p-chloro-m-cresol;
3--o-cymene-5-ol;
4 --- 4-tert-butylphenol;
5--2,4,6-trichlorophenol;
6 --- Pentachlorophenol.
Figure B.1 HPLC chromatograms of six phenolic antibacterial agents
Appendix C (Informative appendix)
Confirmatory test
C.1 Reference conditions for liquid chromatography
The reference conditions for liquid chromatography are as follows.
a) Chromatographic column. C18 column, 1.7 µm, 150 mm × 2.1 mm (inner diameter);
b) Mobile phase. 5mmol ammonium acetate aqueous solution acetonitrile = 60 40 (volume ratio);
c) Flow rate. 0.3mL/min;
d) Column temperature. 30 °C;
e) Injection volume. 5 µL.
C.2 Reference conditions for mass spectrometry
The mass spectrometry conditions are as follows.
a) Ion source. Electrospray ion source (ESI);
b) scanning method. negative ion scanning;
c) Electrospray voltage. -4500V;
d) Ion source temperature. 500 ° C;
e) Air curtain gas. nitrogen, 0.207MPa;
f) collision gas. nitrogen, 0.055MPa;
g) Detection method. Multiple reaction monitoring (MRM).
See Table C.1 for retention time, quantitative ion pairing, qualitative ion pairing, declustering voltage, and collision voltage of the six phenolic antibacterial agents.
The extracted ion chromatogram of the antibacterial standard solution is shown in Figure C.1.
Table C.1. Optimization parameters of the mass spectrometry MRM mode of six phenolic antibacterial agents
Target retention time/min
Quantitative ion pair (m/z)
Qualitative ion pairs (m/z)
De-clustering voltage/V Impact voltage/V
Phenol 2.37 93.0/65.0 93.0/93.0 -75.0 -5.0, -24.0
P-chlorom-cresol 5.10 141.0/105.0 141.0/114.0 -75.0 -50.0, -21.0
O-cymene-5-ol 8.20 149.1/133.0 149.1/117.0 -75.0 -63.0, -21.0
4-tert-butylphenol 8.59 149.1/133.0 149.1/117.0 -75.0 -63.0, -21.0
2,4,6-trichlorophenol 4.56 196.9/161.0 196.9/123.0 -75.0 -39.0, -30.0
Pentachlorophenol 3.69 265.8/265.8 263.6/263.6 -75.0 -5.0, -5.0
Figure C.1 Extracted ion chromatograms of six phenolic antibacterial agents
C.3 Qualitative determination
When performing sample measurement, dilute the sample appropriately, and determine the sample solution and standard working solution according to liquid chromatography-mass spectrometry/mass spectrometry conditions.
The retention time of the chromatographic peak is consistent with that of the standard material, and the selected ion appears in the spectrum of the sample after subtracting the background, and
And the relative abundance of the selected ion is compared with that of the reference material, and the relative deviation does not exceed the range specified in Table C.2, then the existence of the
Among these phenolic antibacterials.
Table C.2 Allowable deviation of relative ion abundance during qualitative confirmation
Relative ion abundance /% > 50 > 20 ~ 50 > 10 ~ 20 <=10
Allowable relative deviation /% ± 20 ± 25 ± 30 ± 50 […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 37544-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 37544-2019
$145.00