Valid

GB/T 37296-2019Safety design code for reciprocating internal combustion engine gas power plant (English PDF)

往复式内燃燃气电站安全设计规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 37296-2019 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 25, 2019

Implementation date

October 1, 2019

Scope

GB/T 37296-2019 is the English-translated version of 往复式内燃燃气电站安全设计规范.

GB/T 37296-2019 is the Chinese standard "Safety design code for reciprocating internal combustion engine gas power plant".

Its scope clause reads: This standard specifies the safety design of reciprocating internal combustion gas power stations (hereinafter referred to as "gas power stations" or "power stations"), including construction (structures) Safety design, safety requirements for gas generator set selection, gas supply system and transmission and distribution system.

This standard is applicable to natural gas, coalbed methane, biogas, straw gas, gas, gas, etc., with a total installed capacity of not less than 500 kW. Engineering design of a fuel-based fixed-reciprocating internal combustion gas-fired power station.

A power station with a total installed capacity of less than 500 kW can be referred to. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 37296-2019

National Standard of the People's Republic of China

ICS
29.160.40
Classification
K 59

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 General
  • 5 Technical requirements
  • 5.1 Power station site selection
  • 5.2 Fire prevention and safety evacuation of power station construction (structure)
  • 5.3 Power plant lightning protection, anti-static and grounding
  • 5.4 Equipment and facilities of the power station
  • 5.5 Room ventilation
  • 5.6 Power station exhaust
  • 5.7 Gas supply system
  • 5.8 Transmission and distribution system
  • 5.9 Fire
  • 5.10 Safety requirements for gas generator set selection
  • 5.11 Safety Sign

1 Scope

This standard specifies the safety design of reciprocating internal combustion gas power stations (hereinafter referred to as "gas power stations" or "power stations"), including construction (structures)

Safety design, safety requirements for gas generator set selection, gas supply system and transmission and distribution system.

This standard is applicable to natural gas, coalbed methane, biogas, straw gas, gas, gas, etc., with a total installed capacity of not less than 500 kW.

Engineering design of a fuel-based fixed-reciprocating internal combustion gas-fired power station.

A power station with a total installed capacity of less than 500 kW can be referred to.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article.

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB 3836 (all parts) Explosive environment

Basic identification color, identification symbol and safety identification of GB 7231 industrial pipeline

GB 25286 (all parts) Non-electrical equipment for explosive atmospheres

GB 50016 Building Design Fire Code

GB 50028 town gas design code

GB 50057 lightning protection design code for buildings

GB 50058 Explosion Hazardous Environment Power Equipment Design Specification

Grounding design specification for GB/T 50065 AC electrical installation

GB 50140 Building Fire Extinguisher Configuration Design Specification

GB 50183 Oil and gas engineering design fire protection specification

GB 50229 Fire power plant and substation design fire protection specification

GB 50257 Electrical Installation Engineering Explosion and Fire Hazardous Environment Electrical Installation Construction and Acceptance Specifications

GB 50316 Industrial Metal Pipe Design Specification

GB 50343 lightning protection technical specification for building electronic information systems

GB 50493 Petrochemical flammable gas and toxic gas detection alarm design specification

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Gas power station

A power supply consisting of one or more gas generator sets and their associated systems.

3.2 Gas pretreatment area gaspreprocessingarea

Install areas for gas storage systems such as gas storage, LNG gasification, purification, pressure regulation, and discharge.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 37296-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37296-2019

$145.00