Scope

GB/T 37295-2019 is the English-translated version of 城市公共设施 电动汽车充换电设施安全技术防范系统要求.

GB/T 37295-2019 is the Chinese standard "Urban public facilities - Requirements for security and protection system of electric vehicle charging/battery swap infrastructure".

Its scope clause reads: This standard specifies the general requirements for security and protection system of electric vehicle charging/battery swap infrastructure in urban public facilities, as well as the relevant requirements for the management and maintenance of charging stations, battery swap stations, dispersal charging facilities.

This standard is applicable to the construction of security and protection systems such as video security monitoring, intrusion alarm, access control for the newly built, reconstructed, expanded electric vehicle charging/battery swap infrastructure in urban public facilities.

Its clauses include terms and definitions; general requirements; charging station; dispersal charging facilities; management and maintenance requirements. It was issued by the State Market Regulatory Administration on MARCH 25, 2019 and took effect on OCTOBER 01, 2019.

Found what you need?

Document preview — GB/T 37295-2019

National Standard of the People's Republic of China

ICS
29.200
Classification
K 81

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions5
  • 4 General requirements6
  • 5 Charging station8
  • 7 Dispersal charging facilities12
  • 8 Management and maintenance requirements12

1 Scope

This standard specifies the general requirements for security and protection system of electric vehicle charging/battery swap infrastructure in urban public facilities, as well as the relevant requirements for the management and maintenance of charging stations, battery swap stations, dispersal charging facilities.

This standard is applicable to the construction of security and protection systems such as video security monitoring, intrusion alarm, access control for the newly built, reconstructed, expanded electric vehicle charging/battery swap infrastructure in urban public facilities.

2 Normative references

The following documents are indispensable for the application of this document.

For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB 16796 Safety requirements and test methods for security alarm equipment

GB/T 29317 Terminology of electric vehicle charging/battery swap infrastructure

GB/T 29781 General requirements for electric vehicle charging station

GB 50348 Technical code for engineering of security and protection system

GB 50394 Code of design for intrusion alarm systems engineering

GB 50395 Code of design for video monitoring system

GB 50396 Code of design for access control systems engineering Supervisory and control center The central control unit of the security system, wherein the security management system receives and processes the alarm information and status information sent by each subsystem, meanwhile sends the processed alarm information and monitoring instructions to the alarm receiving center and related subsystems respectively.

4 General requirements

4.2.2.4 The intrusion alarm system shall be capable of arming/disarming in zones or independently.

4.2.2.5 The alarm signal sent shall be transmitted to the monitoring center. The alarm response time of the system shall not exceed 2 s.

4.2.2.6 The sound and light alarm shall be installed in a conspicuous place.

When the intrusion detector is triggered, the sound and light alarm shall issue sound and light alarm. The indoor alarm sound pressure shall not be less than 80 dB, the outdoor alarm sound pressure shall not be less than 100 dB. The duration shall not be less than 2 min.

4.2.2.7 It shall be able to print alarm reports (including when, where, etc. the alarm occurred as well as the alarm type).

4.2.2.8 The emergency alarm device shall be concealed, easy to operate and clearly marked.

4.2.2.9 The system arming, disarming, alarming, and fault light information shall be stored for not less than 30 days and can be transferred to other storage media and output for printing.

4.1 Basic requirements

4.1.1 The security and protection system should be synchronously designed and constructed but independently accepted with the charging and swap facilities.

4.1.2 Electric vehicle charging and swap facilities shall be equipped with security and protection system according to the specific requirements of charging station, battery swap station, dispersal charging facilities.

4.1.3 The design of security and protection system shall follow the principles of security, stability, expandability, advanced technology, economical rationality, practicality and reliability, fully consider the characteristics of the charging and swap facilities and the importance of the protective objects, adopt corresponding protective measures, to build security and protection system.

4.1.4 The security technical indicators of the equipment and materials used in the security and protection system shall comply with the security performance requirements stipulated in GB 16796 and related product standards.

4.1.5 The security and protection system includes video security monitoring system, intrusion alarm system, access control system, which meets the relevant requirements of GB 50348.

4.1.6 The security and protection system shall realize the unified management of the video security monitoring system, the intrusion alarm system, the access control system. Each system shall be able to achieve linkage and operate independently. Failure of one system shall not affect the normal operation of other systems.

4.1.7 The security and protection system shall select the system and equipment with open communication protocol and interface, have good compatibility, can be integrated with the higher-level management organization, to realize remote centralized monitoring and management.

4.1.8 The security and protection system shall accept the time calibration of the security monitoring system, the access control system, and so on.

4.2.3 Access control system

4.2.3.1 Conditional charging/battery swap facilities may be installed with access control systems, which shall comply with the relevant requirements of GB 50396.

4.2.3.2 The access control system includes functions such as storage, automatic acquisition, uninterrupted shooting, visual recognition, capture, access control identification, anti-smashing induction, voice broadcast.

4.2.3.3 The access control system is capable of storing at least 30 days of vehicle information records. When the maximum storage capacity is exceeded, it automatically overwrites vehicle information and pictures.

4.2.3.4 The access control system can accurately capture and record the traffic information of the passing vehicle. The recorded vehicle information includes information such as date, time (accurate to second), location, direction, license plate, color, etc. in addition to image information.

5 Charging station

5.1 Protection objects

7 Dispersal charging facilities

7.1 Video surveillance, intrusion alarm, access control of dispersal charging facilities shall make full use of the existing security and protection system in the area.

7.2 The video security monitoring system shall cover the relevant areas of the dispersal charging facilities. The protection requirements should refer to the requirements of 5.2.2.1, 5.2.2.2, 5.2.2.4.

7.3 Dispersal charging facilities should be equipped with an intrusion alarm system, to provide an alarm message for the intrusion of power distribution facilities and charging facilities.

7.4 Dispersal charging facilities which may be equipped with other security and protection devices shall be installed according to their own needs.

8 Management and maintenance requirements

8.1 Personnel requirements

8.1.1 The security and protection system shall be equipped with appropriate management and maintenance personnel.

8.1.2 Management and maintenance personnel shall have the corresponding qualifications and be proficient in the knowledge and skills of the operation and maintenance of the security and protection system.

8.1.3 Management and maintenance personnel shall be qualified after training.

8.2 System requirements

8.2.1 It shall clearly define a responsible person, establish and improve a security protection system such as safe operation procedures, daily inspections, special inspections.

8.2.2 It shall establish the emergency response plans for emergencies.

8.3 Operation/maintenance requirements

8.3.1 The system shall be inspected, overhauled, maintained, and serviced regularly to maintain a good operating state of the system and make relevant records.

8.3.2 It shall disclose the key security protection systems, operating procedures, related operational regulations. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 37295-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37295-2019

$125.00