GB/T 36744-2018Forecasting method for ultraviolet index (English PDF)
紫外线指数预报方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36744-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 17, 2018
Implementation date
April 1, 2019
Scope
GB/T 36744-2018 is the English-translated version of 紫外线指数预报方法.
GB/T 36744-2018 gives a method for forecasting the ultraviolet index, based on the ground ultraviolet irradiance corrected for cloud amount, weather phenomena and surface albedo.
It defines solar ultraviolet radiation, ultraviolet irradiance and the ultraviolet index, and gives the equation that turns the forecast irradiance into an index value using an equivalent erythema correction factor of 0.01 and 0.025 W/m² per index unit, with the result rounded up to a non-zero integer.
Informative annexes describe the solar UV bands, the UV index levels, the calculation of astronomical irradiance, and experimental results for the atmospheric transparency coefficient and for the share of ultraviolet in total solar radiation.
It is meant for UV index forecasting work and related research. It was issued on 17 September 2018 and has applied since 1 April 2019.
Found what you need?
Document preview — GB/T 36744-2018
National Standard of the People's Republic of China
- ICS
- 07.060
- Classification
- A 47
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Terms and Definitions
- 3 Index forecasting method
- Appendix A (informative) Solar UV
- Appendix B (informative) UV Index Level
- Appendix C (informative) Astronomical irradiance calculation
- Appendix D (informative) Experimental results of atmospheric transparency coefficient
- Appendix E (informative appendix) Experimental results of ultraviolet radiation in total solar radiation ratio
- Reference
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
Introduction
In July.1994, the World Meteorological Organization (WMO) developed an internationally unified representation of the UV Index. World Health Organization.2002 (WHO), World Meteorological Organization (WMO), United Nations Environment Programme (UNEP) and International Commission on Non-Ionizing Radiation Protection (ICNIRP) jointly developed the "Global Solar UV Index. A Practical Guide", the guidelines for UV index, UV influence factors, purple The effects of the external line on the human body and the UV defense measures are described in detail. Many countries adopt the Global Solar UV Index. Practice The Guide conducts UV index forecasting.
In order to fully link the "Global Solar UV Index. A Practical Guide" to promote the scientific development of China's ultraviolet forecast, this standard is specially formulated to Guide the UV index forecast.
1 Scope
This standard specifies the UV index prediction method based on cloud amount, weather phenomenon and surface albedo correction for ground UV irradiance.
This standard applies to the UV index forecasting work and related scientific research.
2 Terms and definitions
The following terms and definitions apply to this document.
2.1 Solar ultraviolet (UV)
Solar radiation in the solar spectrum with a wavelength range of 100 nm to 400 nm, referred to as ultraviolet light.
Note: The solar ultraviolet light can be divided into three bands according to the biological action of different wavelengths. See Appendix A for details.
2.2 Ultraviolet (line) irradiance
The solar ultraviolet radiation power received per unit area.
Note: The unit is watts per square meter (W/m2). [QX/T 87-2008, Definition 3.2]
2.3 Ultraviolet (line) index (UVI)
A quantitative indicator of the effective irradiance level of erythema on the surface of the sun's ultraviolet radiation. [GB/T 21005-2007, definition 3.10]
Note 1. The UV index is used to measure the extent of possible damage to human skin, eyes and other tissues and organs by the ultraviolet radiation at the strongest moment of sunshine. purple The larger the external line index, the more serious the damage to the human body.
Note 2. See Appendix B for the classification of UV index.
3 Index forecasting method
3.1 UV index calculation
For the calculation of the UV index, see equation (1). IUV ~ Quv·Cer deltaI (1) In the formula.
IUV---UV index forecast value, dimensionless value, non-zero integer, rounded up to get;
Quv---ground ultraviolet irradiance forecast value in watts per square meter (W/m2);
Cer---equivalent erythema correction factor, value 0.01;
deltaI---the ultraviolet irradiance equivalent to the unit ultraviolet index, which is 0.025 W/m².
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 36744-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 36744-2018
$205.00