GB/T 36295-2018 is the English-translated version of 家用和类似用途机械式磁性接近开关.
GB/T 36295-2018 deals with mechanical magnetic proximity switches for household and similar use, which switch on and off under the action of a magnetic field, with rated voltage below AC 380 V or DC 300 V and rated current below 16 A. It gives terms, model naming and classification and the technical requirements: external structure, action distance, insulation resistance, electrical strength and contact resistance, heat and humidity, low and high temperature and thermal shock resistance, heat, flame and tracking resistance, free fall and vibration.
The test methods, with an annex for steam pressure use, inspection rules and marking, packaging, transport and storage follow. It serves switch makers and appliance manufacturers, was issued on 7 June 2018 and has applied since 1 January 2019.
Found what you need?
Document preview — GB/T 36295-2018
National Standard of the People's Republic of China
- ICS
- 97.120
- Classification
- K 32
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Terms and Definitions5
- 4 Model Naming and Classification5
- 5 Technical Requirements6
- 6 Test Methods8
- 7 Inspection Rules11
- 8 Marking, Packaging, Transportation and Storage13
- Appendix A (normative appendix)15
1 Scope
This Standard specifies the terms, definitions, model naming, classification, technical requirements, test methods, inspection rules, marking, packaging, transportation and storage of mechanical magnetic proximity switches (hereinafter referred to as proximity switches) for household and similar use.
This Standard is applicable to proximity switches that bear magnetic sensors and implement switching-on/off under the driving force of magnetic field (rated voltage AC < 380 V, or rated voltage DC < 300 V, rated current < 16 A).
2 Normative References
The following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. The latest version (including all the modifications) of references without a specified date is also applicable to this Standard.
GB/T 191 Packaging - Pictorial Marking for Handling of Goods
GB/T 2423.1 Environmental Testing for Electric and Electronic Products - Part 2. Test Methods - Test A. Cold
GB/T 2423.2 Environmental Testing for Electric and Electronic Products - Part 2. Test Methods - Test B. Dry Heat
GB/T 2423.5 Environmental Testing for Electric and Electronic Products - Part 2. Test Methods - Test Ea and Guidance. Shock
GB/T 2423.10 Environmental Testing for Electric and Electronic Products - Part 2. Test Methods - Test Fc and Guidance. Vibration (Sinusoidal)
GB/T 2828.1-2012 Sampling Procedures for Inspection by Attribute - Part 1. Sampling Schemes Indexed by Acceptance Quality Limit (AQL) for Lot-by-lot Inspection
GB 4706.1 Safety of Household and Similar Electrical Appliances - Part 1. General Requirements
GB/T 14048.10 Low-voltage Switchgear and Control-gear - Part 5-2. Control Circuit Devices and Switching Element - Proximity Switches
5 Technical Requirements
5.4.3 Contact resistance
At room temperature, resistance value shall be < 50 Mohm (contact resistance does not include lead resistance).
5.5 Environmental Adaptability
5.5.1 Heat and humidity resistance
After heat and humidity resistance test (relative humidity. 95%), product shall comply with requirements in 5.3 and 5.4.1.
5.5.2 Low temperature resistance
After low temperature resistance test (at -25 °C), product shall comply with requirements in 5.3 and 5.4.1.
5.5.3 High temperature resistance
After high temperature resistance test (under highest ambient temperature), product shall comply with requirements in 5.3 and 5.4.1.
5.5.4 High and low temperature impact
After high and low temperature impact test (at -25 °C and 120 °C), product shall comply with requirements in 5.3 and 5.4.1.
5.6 Heat, Flame and Tracking Resistance
Proximity switch shall be able to endure.
a) Heat resistance. non-metallic materials that support electrical parts in proximity switch shall be able to endure ball pressure test (at 125 °C). Other parts (for example, external shell) shall be able to endure ball pressure test (at 40 °C higher than the highest ambient temperature);
b) Flame resistance. proximity switch shall be able to endure glow-wire test (at 650 °C, 2 s);
c) Tracking resistance. no breakage or combustion shall be triggered in four grades of test. 175 V, 250 V, 400 V, 600 V (determined in accordance with illustration or instruction for use).
5.7 Free Fall
After free fall test, product shall comply with requirements in 5.3 and 5.4.3.
6 Test Methods
6.2 External Structure and Dimension
Examine in accordance with drawings; the method of visual inspection shall be adopted in external structure; shape and dimension shall be measured directly with corresponding measurer.
6.3 Action Distance
In accordance with the requirements of technical specification negotiated by the demand side and the supply side, link up this product with DC resistance meter at room temperature. Proximity switch and magnet trigger relative displacement; record action distance when the resistance meter displays a numerical value.
6.4 Electrical Performance
6.4.1 Insulation resistance
Link up outgoing line with test electrode, link up the external shell with another side of test electrode; impose 500 V DC voltage for 30 s, then, record the insulation resistance.
6.4.2 Electrical strength
Link up outgoing line with test electrode, link up the external shell with another side of test electrode; conduct the test in accordance with stipulations in GB/T 14536.1.
6.4.3 Contact resistance
Link up outgoing line with resistance meter, maintain the switching-on state, record the resistance value.
6.5 Environmental Adaptability
6.5.1 Heat and humidity resistance
In terms of general purposes, maintain 100 h in a thermostat (temperature. 55 °C ~ 65 °C, relative humidity. 90% ~ 100 %); place 2 h at room temperature. Conduct the test; assess if it satisfies the requirement in 5.4.1. As to heat and humidity resistance test of proximity switch used under the occasion of steam pressure, test shall be conducted in accordance with Appendix A.
8 Marking, Packaging, Transportation and Storage
8.1.2 There shall be a distinct mark on the package, which includes.
a) Name or trademark, address of manufacturer;
b) Production date or batch number;
c) Model and product name;
d) Rated voltage and current;
e) Executive standard number, etc.;
f) Weight, volume and quantity;
g) Packaging storage and transportation mark stipulated in GB/T 191.
8.2 Packaging
Product packaging shall comply with requirements in GB/T 22685.
8.3 Transportation
Proximity switch with intact packaging can be transported with regular means of transportation. sea, land and air; direct attack of rain or snow shall be avoided. Proximity switch shall also be protected from humidity.
8.4 Storage
Packaged proximity switch shall be stored in a warehouse (ambient temperature. - 10 °C ~ + 60 °C, relative humidity <= 95%); there shall be no acid or alkaline gas, or other harmful gas. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 2423.1Environmental testing for electric and electronic products - Part 2: Test methods - Tests A: Cold
- GB/T 2423.2Environmental testing for electric and electronic products - Part 2: Test methods - Tests B: Dry heat
- GB/T 2423.5Environmental testing - Part 2: Test methods - Test Ea and guidance: Shock
- GB/T 2423.10Environmental testing - Part 2: Test methods - Test Fc: Vibration (sinusoidal)
- GB/T 2828.1-2012Sampling procedures for inspection by attributes - Part 1: Sampling schemes indexed by acceptance quality limit (AQL) for lot-by-lot inspection
GB 4706.1
Similar standards
How to Download GB/T 36295-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4706.100-2009 — Household and similar electrical appliances - Safety - Particular requirements for multifunctional shower room
GB 4706.101-2010 — Household and similar electrical appliances -- Safety -- Particular requirements for drives for rolling shutters, awnings, blinds and similar equipment
GB 4706.104-2010 — Household and similar electrical appliances -- Safety -- Particular requirements for heated gullies for roof drainage