GB 4706.100-2009Household and similar electrical appliances - Safety - Particular requirements for multifunctional shower room (English PDF)
Also coversGB4706.100-2009
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB 4706.100-2009 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Mandatory
Issue date
December 15, 2009
Implementation date
November 1, 2010
Scope
GB 4706.100-2009 (Household and similar electrical appliances - Safety - Particular requirements for multifunctional shower room) is available as an English-translated PDF.
GB 4706.100-2009 — This clause in GB 4706.1-2005 is replaced by the following.
This part specifies the safety of the household and similar purposes multifunctional shower room for which the single-phase appliance has a rated voltage of not exceeding 250 V AND the other appliances have a rated voltage of not exceeding 480 V. Items that are not intended to be used as general household BUT which can still be dangerous to the public, such as appliances used by non-professionals in hotels, fitness centers and similar places, are within the scope of this part.
This part deals with the general danger of the presence of appliances that are likely to be encountered in all residential and residential surroundings. This part does not cover. - The risk of using the appliances by unattended child and the disabled; - The risk of child playing appliances.
Note 1.Note the following. - As for the shower room equipped on the vehicle, ship or aircraft, it may require additional requirements; - National health care departments, national labor protection departments, national water supply management departments and similar departments have provided additional requirements for appliances.
Note 2.This section does not apply to. - The appliance designed for medical purposes; - The appliance intended to be used in special environmental conditions wherein corrosive or explosive gases (such as dust, steam, or gas) are frequently produced.
Found what you need?
Document preview — GB 4706.100-2009
National Standard of the People's Republic of China
- ICS
- 13.120
- Classification
- Y 69
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword...4
- 1 Scope...5
- 2 Normative references...5
- 3 Terms and definitions...6
- 4 General requirements...6
- 5 General conditions of test...6
- 6 Classification...6
- 7 Marking and description...7
- 8 Protection against live parts...8
- 9 Startup of electric appliance...8
- 10 Input power and current...8
- 11 Heating...8
- 12 None...8
- 13 Leakage current and electrical strength at working temperature...8
- 14 Transient overvoltage...8
- 15 Moisture resistance...9
- 16 Leakage current and electrical strength...9
- 17 Overload protection of transformer and related circuit...9
- 18 Durability...9
- 19 Abnormal operation...9
- 20 Stability and mechanical hazards...10
- 21 Mechanical strength...10
- 22 Structure...10
- 23 Internal wiring...12
- 24 Components...12
- 25 Power connection and external cord...12
- 26 Terminals for external conductors...12
- 27 Grounding measures...12
- 28 Screws and connections...12
- 29 Electrical clearance, creepage distance and solid insulation...13
- 30 Heat and flame resistance...13
- 31 Rustproof...13
- 32 Radiation, toxicity and similar hazards...13
- Appendix...14
- References...15
Foreword
All technical contents of this part are mandatory.
GB 4706 "Household and similar electrical appliances – Safety" is composed
of several parts, the part 1 is general requirement AND the rest parts are
special requirements.
This part is part 100 of GB 4706.
This part shall be used in conjunction with GB 4706.1-2005 "Household and
similar electrical appliances – Safety – Part 1.General requirements".
The contents in this part which are indicated of "applicable" means that the
corresponding clauses in GB 4706.1-2005 apply to this part; the contents in
this part which are indicated of "replacement" or "modification" shall prevail;
AND the contents in this part which are indicated of "addition" means that in
addition to comply with the corresponding clauses of GB 4706.1-2005, it shall
also comply with the clauses added in this part.
This part was proposed by the China Light Industry Federation.
This part shall be under the jurisdiction of the National Household Electrical
Appliances Standardization Technical Committee.
The main drafting organizations of this part. China Household Electrical
Appliances Research Institute, National Household Electrical Appliances
Quality Supervision and Inspection Center.
1 Scope
This clause in GB 4706.1-2005 is replaced by the following.
This part specifies the safety of the household and similar purposes
multifunctional shower room for which the single-phase appliance has a rated
voltage of not exceeding 250 V AND the other appliances have a rated voltage
of not exceeding 480 V.
Items that are not intended to be used as general household BUT which can
still be dangerous to the public, such as appliances used by non-professionals
in hotels, fitness centers and similar places, are within the scope of this part.
This part deals with the general danger of the presence of appliances that are
likely to be encountered in all residential and residential surroundings.
This part does not cover.
- The risk of using the appliances by unattended child and the disabled;
- The risk of child playing appliances.
Note 1.Note the following.
- As for the shower room equipped on the vehicle, ship or aircraft, it may
require additional requirements;
- National health care departments, national labor protection departments,
national water supply management departments and similar departments
have provided additional requirements for appliances.
Note 2.This section does not apply to.
- The appliance designed for medical purposes;
- The appliance intended to be used in special environmental conditions
wherein corrosive or explosive gases (such as dust, steam, or gas) are
frequently produced.
2 Normative references
The provisions in following documents become the provisions of this Standard
through reference in this part of GB 4706.For the dated references, the
subsequent amendments (excluding corrections) or revisions do not apply to
this Standard; however, parties who reach an agreement based on this
Standard are encouraged to study if the latest versions of these documents are
applicable. For undated references, the latest edition of the referenced
document applies.
This clause in GB 4706.1-2005 is applicable.
3 Terms and definitions
The following terms and definitions as established in GB 4706.1-2005 AND the
following terms and definitions apply to this part of GB 4706.
3.1.9 Replacement.
Normal operation
The appliance shall work under the following conditions.
All the sprinklers in the shower room reach the maximum flow rate, AND the
heating device with heating function is opened to the maximum gear.
3.101
Multifunctional shower room
It refers to the enclosed room which can provide jetting water current or
electromagnetic field from the top, side and other parts, AND has the water
heating function.
4 General requirements
This clause in GB 4706.1-2005 is applicable.
5 General conditions of test
This clause in GB 4706.1-2005 is applicable, except as follows.
5.7 Addition.
If the test is affected by the water temperature, the water temperature shall be
maintained at 40 °C OR the maximum temperature allowed by the controller,
whichever is greater.
6 Classification
This clause in GB 4706.1-2005 is applicable, except as follows.
6.1 Modification.
Multifunction shower room shall be category I, II, or III.
15 Moisture resistance
This clause in GB 4706.1-2005 is applicable, except as follows.
15.1 Addition.
The presence of water trace at the insulation surfaces of components that are
powered by not more than 12 V of safety extra-low voltage is negligible.
15.1.2 Addition.
All the sprinklers of the multifunctional shower room shall spray water at the
maximum flow rate for 10 min.
16 Leakage current and electrical strength
This clause in GB4706.1-2005 is applicable.
17 Overload protection of transformer and related
circuit
This clause in GB 4706.1-2005 is applicable, except as follows.
Addition.
The appliances equipped with chlorinated units shall be repeated of this test,
the test current is 95% of the minimum current which can trigger the prot...
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
GB 4706 · GB 4706.1-2005
How to Download GB 4706.100-2009
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4706.101-2010 — Household and similar electrical appliances -- Safety -- Particular requirements for drives for rolling shutters, awnings, blinds and similar equipment
GB 4706.104-2010 — Household and similar electrical appliances -- Safety -- Particular requirements for heated gullies for roof drainage
GB 4706.105-2011 — Household and similar electrical appliances -- Safety -- Particular requirements for humidifiers intended for use with heating, ventilation, or air-conditioner systems
Secure payment via Stripe
Payments accepted
GB 4706.100-2009