Valid

GB 4706.105-2011Household and similar electrical appliances -- Safety -- Particular requirements for humidifiers intended for use with heating, ventilation, or air-conditioner systems (English PDF)

Preview PDF

Also coversGB4706.105-2011

This is a limited preview

Buy now to download the full PDF

Need quotation for your management?

Get a formal quotation for GB 4706.105-2011 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Mandatory

Issue date

June 16, 2011

Implementation date

December 1, 2011

Scope

GB 4706.105-2011 (Household and similar electrical appliances -- Safety -- Particular requirements for humidifiers intended for use with heating, ventilation, or air-conditioner systems) is available as an English-translated PDF.

GB 4706.105-2011 — The chapter GB 4706.1-2005 is replaced by the following. GB 4706 specifies a part of the present Safety of household and similar purposes with a heating, ventilation or air conditioning system. This section applies with a heating, ventilation or air-conditioning systems in residential, commercial, and light industrial applications (also comprise a large separate commercial apparatus) Electrical humidifier, the apparatus for the atomization or evaporation systems, injection water, production of steam and run in a similar manner, the maximum single-phase rated voltage of the appliance More than 250V; rated voltage of other appliances does not exceed 600V. Note 1. This humidifier incorporating a covered portion of the air conditioning apparatus according to the IEC 60335-2-40. In practical terms, this section relates generally dangerous instruments appear, and these are dangerous in the house and around the house all personnel are You could ever meet. However, this section does not usually consider. --- unattended young children and use for disabled persons; --- children playing instruments situation. Note 2. should note the following. --- ready for use in a vehicle, ship or aircraft, appliances, but also additional requirements; --- health sector, labor protection and similar authorities have also developed additional requirements. Note 3. This does not apply to. --- specifically for household use without a room heating, ventilation or air-conditioning apparatus humidifier (see IEC 60335-2-98); --- designed specifically for industrial use appliances; --- for the appliance in special environmental conditions, such as corrosive or explosive atmosphere (dust, vapor or gas); --- humidifiers for medical purposes (see IEC 60601).

Found what you need?

Document preview — GB 4706.105-2011

National Standard of the People's Republic of China

ICS
23.120
Classification
Y 61

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • 1 Scope1
  • 2 Normative References1
  • Terms and definitions 13
  • 4 General requirements2
  • General conditions for 5 tests2
  • 6 Category2
  • 7 Marking and instructions2
  • 8 Protection against access to live parts3
  • Start electric appliance 39
  • 10 Power input and current3
  • 11 heat3
  • 12 Void3
  • 13 Leakage current and electric strength at operating temperature3
  • 14 Transient overvoltages3
  • 15 Moisture resistance4
  • 16 Leakage current and electric strength4
  • Transformer 17 and associated circuitry overload4
  • 18 Endurance4
  • 19 Abnormal operation4
  • 20 Stability and mechanical hazards4

Foreword

All technical contents of this section is mandatory.

GB 4706 "and similar household electrical appliances," it consists of several components, Part 1 General Requirements for the other parts of special

Claim.

This section is part of the 105 GB 4706.

This section should GB 4706.1-2005. with "safe 1 Household and similar electrical appliances General requirements."

This section is equivalent to using IEC 60335-2-88.2002 "Safety Section 2-88 and similar household electrical appliances. with heating, ventilation,

Particular requirements for humidifiers or air-conditioning system "(2nd edition)

For ease of use, this part of the IEC 60335-2-88.2002 editorial changes made by the following.

The term --- "Part 1" to "GB 4706.1";

--- with a decimal point. "" Used in place of a decimal point "."

This appendix AA, BB appendix is normative.

This section was proposed by China Light Industry Federation.

This part of the jurisdiction of the National Standardization Technical Committee appliances (SAC/TC46).

This part of the drafting unit. China Academy of household appliances, household appliances National Quality Supervision and Inspection Center, Shenzhen Entry-Exit Inspection and Quarantine Bureau.

1 Scope

The chapter GB 4706.1-2005 is replaced by the following.

GB 4706 specifies a part of the present Safety of household and similar purposes with a heating, ventilation or air conditioning system.

This section applies with a heating, ventilation or air-conditioning systems in residential, commercial, and light industrial applications (also comprise a large separate commercial apparatus)

Electrical humidifier, the apparatus for the atomization or evaporation systems, injection water, production of steam and run in a similar manner, the maximum single-phase rated voltage of the appliance

More than 250V; rated voltage of other appliances does not exceed 600V.

Note 1. This humidifier incorporating a covered portion of the air conditioning apparatus according to the IEC 60335-2-40.

In practical terms, this section relates generally dangerous instruments appear, and these are dangerous in the house and around the house all personnel are

You could ever meet. However, this section does not usually consider.

--- unattended young children and use for disabled persons;

--- children playing instruments situation.

Note 2. should note the following.

--- ready for use in a vehicle, ship or aircraft, appliances, but also additional requirements;

--- health sector, labor protection and similar authorities have also developed additional requirements.

Note 3. This does not apply to.

--- specifically for household use without a room heating, ventilation or air-conditioning apparatus humidifier (see IEC 60335-2-98);

--- designed specifically for industrial use appliances;

--- for the appliance in special environmental conditions, such as corrosive or explosive atmosphere (dust, vapor or gas);

--- humidifiers for medical purposes (see IEC 60601).

2 Normative references

Terms of the following documents constitute provisions of this section by reference in this part of GB 4706. For dated references,

All subsequent amendments (excluding corrections) or revisions do not apply to this section, however, encouraged to reach an agreement under this section

Whether the parties to use the latest versions of these documents. Those who did not note date reference documents, the latest versions apply to this section.

GB 4706.1-2005 in this chapter except as follows, are applicable.

increase.

GB/T 2423.18-2000 Environmental testing for electric and electronic products - Part 2. Test Method Test Kb. Salt mist, cyclic (chloride

Sodium) (idtIEC 60068-2-52.1996)

GB 4706.32 similar household electrical appliances and the special requirements of heat pumps, air conditioners and dehumidifiers (GB 4706.32-

2004, IEC 60335-2-40.1995, IDT)

Particular requirements for humidifiers GB 4706.48 Household and similar electrical appliances (GB 4706.48-2009, IEC 60335-2-40.

2005, IDT)

ISO 815.1991 Determination of compression set and at low temperature high temperature vulcanized or thermoplastic rubber

3 Terms and Definitions

The following terms and definitions apply to this part of GB 4706.

GB 4706.1-2005 in this chapter except as follows, are applicable.

3.1.9 Replacement.

Work normaloperation

Conditions of normal use by appliances install and run specified by the manufacturer under the most severe operating conditions located.

3.101

Humidifier humidifiers

Instrument for increasing air humidity.

3.102

Public accessible appliance appliancesaccessibletothegeneralpublic

Placed in a residential or commercial building equipment.

3.103

Public inaccessible appliance appliancesnotaccessibletothegeneralpublic

Maintained by qualified service personnel, and placed in the engine room and similar areas, or placed highly in the area of not less than 2.5m, or packed in

Appliances roof area of security.

4 General requirements

This chapter in GB 4706.1-2005 is applicable.

General conditions for 5 tests

This chapter in GB 4706.1-2005 is applicable.

Category 6

GB 4706.1-2005 in this chapter except as follows, are applicable.

6.1 Replacement.

As a class should implement I, II III class or classes of appliances.

Compliance is checked by inspection and the associated additional testing.

6.101 appliance shall be classified according to accessibility 3.102 and 3.103 definition.

Determine whether it is checked by inspection and relevant tests.

7 Marking and instructions

GB 4706.1-2005 in this chapter except as follows, are applicable.

7.1 Addition.

For the humidifier water connection.

The maximum allowable pressure water system (expressed in Pascal).

Generating over 60 °C water or steam humidifier warning sign should have the following.

WARNING. Beware of hot water hazard. Before servicing the water should be drained.

7.12 Addition.

For the public accessible appliance, should include a classified in accordance with 6.101.

7.12.1 increase.

Special instructions should provide the following information.

--- appliances shall be installed in accordance with national wiring rules;

--- properly size the installation space required for the appliance, including the minimum permissible distance from adjacent structures;

--- appliance and has a gap with respect to the combustible surface resistance heaters, should a predetermined minimum clearance between the appliance and the combustible surface;

--- appliance clearly showing the wiring pattern of the wiring and the external control apparatus;

--- appliance external static pressure measurement range of the test gas flow at the point (only the auxiliary pump, and the appliance with auxiliary heater);

--- type and rating of fuse.

7.15 Addition.

If the panel can be removed during installation or maintenance, but is still in its place as long as the appliance is in operation, the flag can be placed on the panel.

7.16 Addition.

The overload protection requirements also apply.

7.101 If the product is ready to use aluminum wire permanently connected to fixed wiring, you should sign the statement said.

Determine whether it is checked by inspection.

8 Protection against access to live parts

This chapter in GB 4706.1-2005 is applicable.

9 start electric appliances

The chapter GB 4706.1-2005 not apply.

Power input and current 10

The chapter of GB 4706.1-2005 is applicable except as follows.

10.1 increase.

Humidifiers or bare electrode resistance with resistance heating means, since there will be residual water concentration of the conductive component at the heating device

Increases, the use of special test water having a resistivity 2000ohmcm temperature 15 °C The test is performed.

101 Note. can be obtained by adding ammonium in water to achieve the above resistance values. Other additives such as salt, can be used.

11 fever

GB 4706.1-2005 in this chapter except as follows, are applicable.

11.7 Replacement.

The appliance is operated until steady conditions are established.

12 Void

13 Leakage current and electric strength at operating temperature

GB 4706.1-2005 in this chapter except as follows, are applicable.

13.1 increase.

For humidifiers and humidifier apparatus with a bare resistance heating electrode resistance heating means, the use of special test water in the feed 10.1

Line 13.2 and 13.3 of the tests specified.

13.2 Review.

For fixed wiring connected to the appliance, the leakage current should not exceed 2mA/kW rated input power. For the public accessible appliances,

The maximum value of leakage current should not exceed 5mA; appliance inaccessible to the public, the maximum leakage current should not exceed 10mA.

Leakage current electrode of the filter should not exceed the following values.

--- appliances 1.0mA class I

--- of classes and class III II appliances 0.50mA

14 transient overvoltage

This chapter in GB 4706.1-2005 is applicable.

15 Moisture resistance

This chapter in GB 4706.1-2005 is applicable.

16 Leakage current and electric strength

GB 4706.1-2005 in this chapter except as follows, are applicable.

16.1 increase.

For humidifiers and humidifier apparatus with a bare resistance heating electrode resistance heating means, the use of special test water in the feed 10.1

Tests specified in Chapter 16 rows.

16.2 increase.

For fixed wiring connected to the appliance, the leakage current should not exceed 2mA/kW rated power input, the appliance accessible to the public,

The maximum value of leakage current should not exceed 5mA; appliance inaccessible to the public, the maximum leakage current should not exceed 10mA.

Overload protection of transformers and associated circuitry 17

This chapter in GB 4706.1-2005 is applicable.

18 Endurance

The chapter GB 4706.1-2005 not apply.

19 Abnormal operation

GB 4706.1-2005 in this chapter except as follows, are applicable.

19.2 increase.

The test was conducted under anhydrous appliance state.

19.3 increase.

The test was conducted under anhydrous appliance state.

19.4 increase.

The controller operates during the test of Clause 11 does not work. Humidifiers with fan, the fan off or cut off the air, taken

Its worst state.

The appliance or filling water to the heating element is not exactly over the electrode, and then to stop water supply. The water in the appliance is completely evaporated.

20 Stability and mechanical hazards

This chapter in GB 4706.1-2005 is applicable.

21 Mechanical strength

This chapter in GB 4706.1-2005 is applicable.

22 Construction

GB 4706.1-2005 in this chapter except as follows, are applicable.

22.6 increase.

Appliance shall be constructed so that leakage of water or condensate flowing to the condensed water or water leakage does not affect the electrical insulation. If there are for this purpose

Provided drainage holes, the hole should have a diameter of at least 6mm, or with a 30mm2 area of at least 5mm width.

If necessary, it may be determined whether a checked by measurement.

22.7 increase.

If the liner must meet the requirements of this chapter, it shall comply with the requirements of Appendix AA.

If necessary, it may be determined whether a checked by measurement.

22.33 Review.

Heating the liquid allows the use of electrodes.

22.101 structural water system should be such that the humidifier container is always in communication with the atmosphere through a small hole, the hole should have a straight of at least 6mm

Diameter, or an area of at least 30mm2 5mm width. Aperture should be located in a position likely to be blocked in normal use.

To determine whether it is checked by inspection and manual test.

22.102 humidifier with electrode heating means should be provided before the input current exceeds 150% of rated current to the heating means of the all-pole disconnection

Device.

To determine whether it is checked by inspection.

22.103 fixed installation intended and designed for direct connection to the humidifier water supply line, should be individually connected to the source of water held by the

In place, but rather to provide fastening means (e.g., fastening means for wall mounting). It should provide an effective means for preventing air gap

Non-return.

To determine whether it is checked by inspection.

NOTE. small holes in the form of pin holes, a hook and eye, etc. is not considered a safety device fixed humidifier, unless removed from the humidifier to prevent the fixing apparatus Mining

Take additional measures.

22.104 operation request for replacement after which the non-self-resetting thermal trip, the wiring connected thereto have to be fixed so that the heat release of the applied installation

Thermal or thermal trip element assembly itself is not damaged when changing internal wiring or other connections.

By inspection and manual test (if necessary) to determine their eligibility.

22.105 designed to be replaced after their operation a non-self-resetting thermal trip open the circuit in a predetermined manner should not be very different

Short circuit of the charging member and the charging member does not result in contact with the housing.

Determining whether checked by the following tests.

Working tool 5, each time using a new non-self-resetting thermal trip, short-circuiting all other heat control means.

Each time, the heat release should be action.

During the test, the enclosure means to ground through a 3A fuse, the fuse should not melt.

After the test, the auxiliary heat generating element to be a predetermined electrical strength test 16.3.

22.106 hazardous material if the liquid container, the sealing means or the like will increase deterioration or breakage of electrical shock, the member should be resistant to

To contact with water erosion.

To determine whether they qualified through tests of Appendix BB.

Internal wiring 23

This chapter in GB 4706.1-2005 is applicable.

Element 24

This chapter in GB 4706.1-2005 is applicable.

25 and the external power connection cord

GB 4706.1-2005 in this chapter except as follows, are applicable.

25.1 Replacement.

The article relates to the appliance power cable may be.

--- If the appliance is for indoor use only;

--- if the appliance is less than or equal nominal rating. 25A;

--- wire appliance if the appliance comply with the relevant specific requirements of the respective country of use connected appliances.

Appliances shall not incorporate an appliance inlet.

To determine whether it is checked by inspection.

External terminal conductors 26

This chapter in GB 4706.1-2005 is applicable.

27 earthing

This chapter in GB 4706.1-2005 is applicable.

28 and screw connection

This chapter in GB 4706.1-2005 is applicable.

Clearances 29, creepage distances and solid insulation

GB 4706.1-2005 in this chapter except as follows, are applicable.

29.2 increase.

For any gas stream is located at the insulation, the microscopic level of environmental pollution grade 3, unless the insulation is not encapsulated or in which the position of

It can be contaminated during normal use of the appliance.

30 Resistance to heat and fire

GB 4706.1-2005 in this chapter except as follows, are applicable.

30.2.2 Not applicable.

31 rust

GB 4706.1-2005 in this chapter except as follows, are applicable.

increase.

2 is a salt spray test to determine whether it is qualified by GB/T 2423.18-2000 in severity.

Before the test, characterize the coating with hardened needle. An end portion of the needle as a conical apex angle of 40 °, a rounded tip radius of 0.25mm ±

0.02mm. Applying an appropriate load to the needle, so the force applied axially to 10N ± 0.5N. Along the coating surface of about

20mm/s speed drag needle, scoring five scratches, scratches distance of at least 5mm, and at least 5mm from the edge.

After the test, the appliance should not affect the degree of damage to this part of the accord, especially Chapters 8 and 27. Coating should not rupture or from

Loose metal surface.

32 radiation, toxicity and similar hazards

GB 4706.1-2005 in this chapter except as follows, are applicable.

increase.

101 Note. the manufacturer's recommended additives should not cause any danger.

appendix

Appendix GB 4706.1-2005 is applicable except as follows.

Appendix AA

(Normative)

liner

Materials indicated in Table AA.1 sealing gasket for electrical enclosure should have the physical properties specified in Table AA.1, which property is

Before the substance under the conditions of Table AA.2 accelerated aging test specified in and after having physical properties.

Gasket material other than the material given in Table AA.1, should be non-absorbent, and should have an equivalent resistance to aging and

Heat.

Physical properties Table AA.1 cushion material

Physical properties of materials

Allowable limit

After aging Before aging

Elastic material

(Neoprene, rubber, ethylene,

Propylene and the like)

Allowing a minimum elongation

The minimum allowable tensile strength

The maximum allowable deformation value b

The maximum allowable compression ratio c

250%

10.3MPad

6.4mm

15%

65% of the original length

75% of the original length

Non-elastic material

(Solid polyvinyl chloride and the like

Materials, not including softwood, and fibers

Similar substance)

Minimum permissible elongation

The minimum allowable tensile strength

200%

10.3MPa

65% of the original length

75% of the original length

Foamed neoprene or rubber compounding

Compound

The mixture should not ...

END: Draft Version (GB 4706.105-2011)

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.

Referenced standards

Normative references

GB 4706 · GB 4706.1-2005 · GB 4706.32 · IEC 60335 · GB 4706.48 · GB 4706.48-2009 · ISO 815.1991

How to Download GB 4706.105-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 4706.105-2011

$140.00