GB/T 36273-2018Digital interface technical specification for relaying protection and security automatic equipment in smart substation (English PDF)
智能变电站继电保护和安全自动装置数字化接口技术规范
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36273-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 7, 2018
Implementation date
January 1, 2019
Scope
GB/T 36273-2018 is the English-translated version of 智能变电站继电保护和安全自动装置数字化接口技术规范.
GB/T 36273-2018 sets out the digital interfaces of the relay protection and security automatic devices installed in smart substations.
It covers the virtual terminal interfaces, the physical interfaces of the process layer, the configuration of the pressure plates (platens), the modelling of the secondary circuits of the process layer, the requirements placed on related equipment and the project configuration files, with an informative annex on the format of loop example configuration files.
It applies to relay protection and security automatic devices of 110 kV (66 kV) and higher voltage classes in smart substations, and draws on GB/T 14285, GB/T 30155, GB/T 32890, DL/T 282 and the DL/T 860 series.
Device manufacturers, design institutes and grid operators use it when designing and integrating these devices. It was issued on 7 June 2018 and has applied since 1 January 2019.
Found what you need?
Document preview — GB/T 36273-2018
National Standard of the People's Republic of China
- ICS
- 29.240
- Classification
- K 45
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions, Abbreviations
- 4 General
- 5 Virtual Terminal Interface Specification
- 6 Physical Interface Specification
- 7 Platen Configuration
- 8 Process Layer Secondary Loop Modeling
- 9 Requirements for related equipment
- 10 Project Configuration File
- Appendix A (Informative) Loop Example Configuration File Format Requirements
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the virtual terminal interface specification for smart substation relay protection and safety automation devices, the physical interface specification for the process layer, and the pressure plate Configuration, process layer secondary loop modeling, requirements for related equipment, project configuration files.
This standard is applicable to various relay protection and safety automatic devices of 110kV (66kV) and above voltage classes in smart substations.
The device is referred to as "device" below and is referenced to a device with a voltage rating of 110 kV (66 kV) or less.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest version (including all amendments) applies to this document.
GB/T 14285-2006 Technical specifications for relay protection and safety automatic devices
GB/T 30155-2013 Technical Guidelines for Smart Substations
GB/T 32890-2016 Relay protection IEC 61850 engineering application model
GB/T 34132-2017 Smart Substation Intelligent Terminal Device General Specifications
GB/T 51071-2014 330kV~750kV intelligent substation design specification
GB/T 51072-2014 110(66)kV~220kV Intelligent Substation Design Specification
DL/T 282 Merging Unit Technical Conditions
DL/T 860 (all parts) Substation Communication Network and System
DL/T 1663-2016 Smart Substation Relay Protection Online Monitoring and Intelligent Diagnostic Technical Guidelines
3 Terms and Definitions, Abbreviations
3.1 Terms and Definitions
GB/T 14285-2006, GB/T 30155-2013, GB/T 51071-2014, GB/T 51072-2014, DL/T 860, The terms and definitions defined in DL/T 282 apply to this document.
3.2 Abbreviations
The following abbreviations apply to this document.
CID. IED instance configuration (ConfiguredIEDDescription)
CRC. Cyclic Redundancy Check
GOOSE. GenericObjectOrientedSubstationEvents for Generic Object Substation Events
ICD. IEDCapabilityDescription
IED. Intelligent Electronic Device (InteligentElectronicDevice)
SCD. Substation Configuration Description
SSD. System Specification Description
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 14285-2006Technical code for relaying protection and security automatic equipment
- GB/T 30155-2013Technical guide for smart substation
- GB/T 32890-2016Data model of protective relays based on IEC 61850
- GB/T 34132-2017General specification for smart terminal in smart substation
- GB/T 51071-2014Code for design of 330kV~750kV smart substation
- GB/T 51072-2014Code of design of 110 (66) kV~220kV smart substation
DL/T 860
Similar standards
How to Download GB/T 36273-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 282-2018 — Technical requirement for merging unit
DL/T 2820-2024 — Technical Supervision Guidelines for Waste-to-energy Plants
DL/T 2821-2024 — Technical Guidelines for Stacking and Storage of Biomass Fuels
Secure payment via Stripe
Payments accepted
GB/T 36273-2018
$205.00