GB/T 36266-2018 is the English-translated version of 淋浴房玻璃.
GB/T 36266-2018 covers the glass used in interior shower enclosures and panels.
It sets out the classification, materials, requirements, test methods, inspection rules, and marking, packaging, transportation and storage of this glass, with normative references to flat, tempered, laminated and heat-strengthened glass, PVB interlayers and performance films.
Test methods include appearance quality viewed from 1 m, dimensional deviation, resistance to chemicals and dirt, and a dry-wet cycle in which samples stand in water poured in at (85 ± 1) °C, are dried at (50 ± 2) °C and are cycled 20 times.
Inspection rules set sampling and how single pieces and the batch are judged, including the falling-ball, shot-bag, chemical and dry-wet results. It was issued on 7 June 2018 and has applied since 1 July 2019.
Found what you need?
Document preview — GB/T 36266-2018
National Standard of the People's Republic of China
- ICS
- 81.040.30
- Classification
- Q 34
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative References4
- 3 Terms and Definitions4
- 4 Classification5
- 5 Materials5
- 6 Requirements5
- 7 Test Methods8
- 8 Inspection Rules13
- 9 Packaging, Marking, Transportation and Storage16
- Reference17
1 Scope
This Standard specifies the classification, materials, requirements, test methods, inspection rules, and marking, packaging, transportation and storage of glass for shower enclosures.
This Standard is applicable to glass for interior shower enclosures and panels.
2 Normative References
The following documents are indispensable to the application of this Standard. In terms of references with a specified date, only versions with a specified date are applicable to this Standard. The latest version (including all the modifications) of references without a specified date is also applicable to this Standard.
GB/T 1216 External Micrometer
GB 5749 Sanitary Standard for Drinking Water
GB/T 9985 Detergents for Hand Dishwashing
GB 11614 Flat Glass
GB 15763.2 Safety Glazing Materials in Building - Part 2. Tempered Glass
GB 15763.3-2009 Safety Glazing Materials in Building - Part 3. Laminated Glass
GB/T 17841 Heat Strengthened Glass
GB/T 22523 Feeler Gauge
GB/T 29061 Performance Films for Glass in Building
JC/T 2166 Polyvinyl Butyral (PVB) Interlayer for Laminated Glass
JG/T 465 Edge Protection Materials for Solar Photovoltaic Laminated Glass for Building
3 Terms and Definitions
The following terms and definitions, and what is defined in GB 15763.3-2009 are applicable to this Standard.
6 Requirements
Safety impairment is triggered when the following requirements are simultaneously satisfied.
a) Crack or breakage is allowed to exist during the damage, but crack or breakage that allows a ball (diameter. 76 mm) to pass under the maximum thrust of 25 N is now allowed;
b) When fragment stripping emerges after the impact, weigh fragments that strip off from the sample within 3 min after the impact. The total mass of fragments shall be <= the mass of 100 cm² of sample; the maximum mass of stripped fragments shall be < the mass of 44 cm² of sample.
6.8 Resistance to Chemicals and Dirt
After test, the surface of the sample shall not manifest the following adverse phenomena. permanent dirt, softening, tackiness, fracturing or obvious devitrification.
6.9 Resistance to Dry-wet Cycle
After test, the sample shall not manifest the following adverse phenomena. breakage, fracturing, blistering, demolding or degumming.
7 Test Methods
7.1 Test Conditions
Apart from special stipulations, test shall be conducted under the following conditions.
a) Ambient environment. 20 °C ± 5 °C;
b) Atmospheric pressure. 8.60 x 10^4 Pa ~ 1.06 x 10^5 Pa;
c) Relative humidity (RH). 40% ~ 80%.
7.2 Appearance Quality
Take a product as the sample; vertically place the sample under relatively favorable natural light or scattered illumination; observe the glass from a distance of 1 m under a vertical direction. Determine the dimension of point defect and the width of linear defect with a reading microscope (10 times magnification, division value. 0.1 mm).
Measure linear defect, burst length and open edge with a steel ruler (minimum division value. 1 mm) or other measuring instruments with equivalent division value. Conduct visual inspection of edge, corner, crack, degumming, demolding, fluff, splicing, wrinkle and stripe.
7.3 Dimensional Deviation
7.9.3 Test procedure
7.9.3.1 Use hot soapy water to clean the surface of the sample; use cotton to wipe it clean.
7.9.3.2 Transfer the test solution and respectively drop it (1.0 mL) onto the coated surface and glass surface of the sample; take a glass cup (caliber. 40 mm) to cover it; place it evenly for (2 ± 0.25 h) at ambient temperature; keep away from direct sunlight.
Use deionized water or distilled water to clean the surface of the sample; use cotton to wipe it clean. Each reagent shall have independent test area or test sample.
7.9.3.3 After the test, record whether the reagent triggers adverse phenomena, such as dirt, softening, tackiness, fracturing or obvious devitrification.
7.10 Resistance to Dry-wet Cycle
7.10.1 Sample
The sample is flat glass (specification. 300 mm x 300 mm) that is manufactured under the same processing technology with the same materials.
The inner cavity of the sink is rectangular solid (bottom area <= 0.3 m²).
Drinking water that complies with requirements in GB 5749 shall be adopted as test water; detergent shall comply with requirements in GB/T 9985.
7.10.2 Test procedure
7.10.2.1 Vertically place 3 PCS of sample on the shelf; place it in the sink.
7.10.2.2 Import (85 ± 1) °C water into the sink, till the sample is 200 mm sunken in water. Naturally cool it down for (8 ± 0.25) h while keeping the sink open.
7.10.2.3 Take the sample out of the sink; use soft and wet cotton to wipe water stain on the surface; place it in (50 ± 2) °C oven and dry it for (16 ± 0.25) h.
7.10.2.4 Take the sample out of the oven; repeat the above step, start cycling for 20 times.
7.10.2.5 If the test is forced to be suspended, place the sample in (50 ± 2) °C oven and temporarily store it in the oven. During the test, avoid mutual contact among samples, and contact among the sample, and the walls of the sink and the oven.
7.10.2.6 Use detergent and blush solution (concentration. 100 g/L) to prepare a mixed solution by volume ratio. 1. 1,000. After 20 times of cycling, use soft sponge or paint brush that is dipped into this solution to slightly brush the surface of the sample. After reserving the solution for (5 ± 1) min, use clean soft wet cotton to wipe it clean. Conduct visual observation and record whether there are blush trace or other changes on the […]
8 Inspection Rules
8.4.2 Inspection items
Inspection items include all the requirements in Chapter 6.
8.4.3 Group batch
Same as 8.3.2.
8.4.4 Sampling
8.4.4.1 Appearance quality, dimensional deviation, thickness deviation, stack deviation and flatness
Same as 8.3.3.
8.4.4.2 Resistance to chemicals and dirt
Randomly take 3 PCS from products that pass the inspection of appearance quality, dimensional deviation, thickness deviation, stack deviation and flatness.
8.4.5 Determination
8.4.5.1 Block determination
During the inspection of appearance quality, dimensional deviation, thickness deviation, stack deviation and flatness, and resistance to chemicals and dirt, when various indexes in the inspection result of a piece of glass can comply with the requirements of corresponding stipulations, this piece of glass shall be determined as qualified, otherwise, it shall be determined as unqualified.
8.4.5.2 Comprehensive determination
8.4.5.2.1 The inspection of appearance quality, dimensional deviation, thickness deviation, stack deviation and flatness shall be the same as 8.3.4.2.1.
8.4.5.2.2 During the falling-ball impact and stripping performance test of 6 PCS of sample, when >= 5 PCS comply with the requirements, it shall be determined as qualified; when <= 3 PCS comply with the requirements, it shall be determined as unqualified; when 4 PCS comply with the requirements, another 6 PCS of new sample shall be re-inspected, and it shall be determined as qualified when all 6 PCS comply with the requirements.
8.4.5.2.3 During shot-bag impact performance test of 4 PCS of sample, it shall be determined as qualified when all the requirements are satisfied.
8.4.5.2.4 Respectively take 3 PCS of sample for the test of resistance to chemicals, dirt and dry-wet cycle, when 3 PCS comply with the requirements, it shall be determined as qualified; when 1 PCS complies with the requirements, it shall be […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 36266-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11614-2022 — Flat glass
GB 15763.3-2009 — Safety glazing materials in building -- Part 3: Laminated glass
GB 5749-2022 — Standards for drinking water quality
Secure payment via Stripe
Payments accepted
GB/T 36266-2018
$125.00