Scope

GB/T 36240-2018 is the English-translated version of 离子色谱仪.

GB/T 36240-2018 is the Chinese national standard for ion chromatographs fitted with conductivity, UV-visible or electrochemical detectors. It specifies requirements, test methods, inspection rules and marking, packaging, transportation and storage.

The requirements start from normal working conditions of 15 °C to 35 °C, 20% to 85% relative humidity and a 220 V ± 22 V, 50 Hz ± 0.5 Hz supply, then cover appearance, the infusion pump, whose pressure must reach at least 90% of the nominal value with a drop of no more than 5 MPa ten minutes after stopping, flow setting and flow stability errors, the thermostat system, detectors, overall performance, safety, electromagnetic compatibility and environmental adaptability.

Annexes cover solution preparation and reference ion chromatograms. It was issued on 7 June 2018 and has applied since 1 January 2019.

Found what you need?

Document preview — GB/T 36240-2018

National Standard of the People's Republic of China

ICS
17.180.99
Classification
N 52

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Requirements
  • 3.1 Normal working conditions
  • 3.2 Appearance
  • 3.3 Infusion pump
  • 3.4 Thermostat system
  • 3.5 detector
  • 3.6 Machine performance
  • 3.7 Security
  • 3.8 Electromagnetic Compatibility
  • 3.9 Power Supply Voltage and Frequency Test
  • 3.10 Environmental Adaptability
  • 3.11 Complete set
  • 3.12 Transportation, transportation and storage
  • 4 Test method
  • 4.1 Test conditions
  • 4.2 Appearance
  • 4.3 Infusion system
  • 4.4 Thermostat system
  • 4.5 Detector
  • 4.6 Overall performance
  • 4.7 Security
  • 4.8 Electromagnetic Compatibility
  • 4.9 Power supply voltage and frequency
  • 4.10 Environmental Adaptability
  • 4.11 Complete set
  • 4.12 Transportation, transportation and storage
  • 5 Inspection rules
  • 5.1 Inspection classification
  • 5.2 Factory inspection
  • 5.3 Type test
  • 6 Marking, packaging, transportation, storage
  • 6.1 Mark
  • 6.2 Packing
  • 6.3 Transportation
  • 6.4 Storage
  • Appendix A (informative) Preparation of solution
  • Appendix B (informative) Standard Correlation Ion Chromatogram

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies the requirements, test methods, inspection rules and marking, packaging, transportation and storage of ion chromatographs.

This standard applies to ion chromatographs (hereinafter referred to as instruments), including conductivity detectors, UV-visible detectors and electrochemical detectors.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 191-2008 packaging storage and transportation icon

GB/T 2829-2002 Periodic inspection count sampling procedures and tables (applicable to the inspection of process stability)

GB 4793.1-2007 Safety requirements for electrical equipment for measurement, control and laboratory - Part 1. General requirements

GB 4824-2013 Industrial, scientific and medical (ISM) radio frequency equipment disturbance characteristics limits and methods of measurement

GB/T 11606-2007 Analytical instrument environmental test method

GB/T 12519-2010 General technical conditions for analytical instruments

GB/T 13384-2008 General technical conditions for mechanical and electrical product packaging

GB/T 18268.1-2010 Electromagnetic compatibility requirements for electrical equipment - Part 1. General requirements

3 Requirements

3.1 Normal working conditions

The instrument should work properly under the following conditions.

a) Ambient temperature. 15 ° C ~ 35 ° C;

b) Relative humidity. 20%~85%;

c) Power supply. voltage 220V ± 22V, frequency 50Hz ± 0.5Hz;

d) The room should be clean and dust-free, and the exhaust air should be good. The instrument should be placed on the workbench smoothly without strong mechanical vibration and electromagnetic drying around. Disturbance source

e) The instrument is well grounded.

3.2 Appearance

3.2.1 The appearance of the instrument should be flat, the writing should be clear, the surface should be coated with uniform color, and there should be no obvious scratches, exposed bottoms, cracks, blistering, etc.

3.2.2 Each adjustment knob, button, switch, etc. works normally, without looseness; the indication and display should be clear and complete.

3.3 Infusion pump

3.3.1 The infusion line and the interface should be tight and tight, and there is no leakage within the specified allowable pressure range. Pump pressure should not be less than the nominal pressure of the instrument 90% of the value, 10 minutes after stopping the pump, the pressure drop should not exceed 5MPa.

3.3.2 Flow setting error (SS) and flow stability error (SR) shall comply with the requirements of Table 1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 36240-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 36240-2018

$295.00