GB/T 43688-2024Quality control method for magnetic resonance imaging and spectrometry systems (English PDF)
磁共振成像/波谱仪质量控制方法
Open the GB/T 43688-2024 preview as PDF
This is a limited preview
Buy now to download the full PDF (25 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 15, 2024
Implementation date
October 1, 2024
Scope
GB/T 43688-2024 is the English-translated version of 磁共振成像/波谱仪质量控制方法.
China's national quality control method for magnetic resonance imaging and spectrometry systems. An MRI scanner degrades in ways that are invisible in the images it produces until they are severe: the main field drifts and loses homogeneity, the gradient calibration shifts so that distances in the image are wrong, the radiofrequency coils lose sensitivity unevenly, and the signal to noise ratio falls. None of that announces itself - the images still look like images - and a radiologist reading them has no way to know. So the machine is tested periodically against a phantom of known geometry and composition, and the measurements are tracked over time: geometric accuracy, slice thickness and position, spatial resolution, image uniformity, signal to noise, and ghosting. The value is in the trend rather than the absolute figure, which is why the method has to be repeatable enough that a change means something.
Document preview — GB/T 43688-2024
National Standard of the People's Republic of China
- ICS
- 17.180.99
- Classification
- L 50
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and Definitions1
- 4 Principle2
- 5 Measurement conditions3
- 6 Measuring instruments3
- 6.1 Standard phantom3
- 6.2 Standard coil3
- 7 Control Flow3
- 7.1 Overview3
- 7.2 Personnel Control Process4
- 7.3 General Control Flow4
- 8 Data Processing7
- 8.1 Processing of numerical data7
- 19 Reference21
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part
1.Structure and drafting rules for standardization documents" Drafting. Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the Chinese Academy of Sciences. This document is under the jurisdiction of the National Technical Committee for Standardization of Photoelectric Measurement (SAC/TC487). This document was drafted by: China Institute of Metrology, Peking University Third Hospital, Shanghai United Imaging Medical Technology Co., Ltd., China Academy of Sciences Aerospace Information Innovation Institute, Guangdong Zhongliang Testing Co., Ltd., Peking University, Beijing University of Aeronautics and Astronautics, Beijing Wandong Medical Science Technology Co., Ltd., Chongqing University, China University of Metrology, Midea Group (Shanghai) Co., Ltd., Beijing Institute of Graphic Communication, Guangdong Provincial Architectural Design Research Institute Co., Ltd., Guangzhou Institute of Metrology and Testing Technology, and Shandong First Medical University. The main drafters of this document are. Liu Zilong, Han Hongbin, Li Yuxiao, Li Jin, Lian Yusheng, Xu Zheng, He Qingyuan, Liu Wenli, Cai Zhe, Lu Yonghong, Wan Yunjie, Li Zhuoran, Wang Pu, Zhang Shuqin, Xing Xiaocong, Wang Zhibo, Wang Xuezheng, Fu Yu, Yuan Lan, Wang Huan, Wang Liwen, Wang Hong, Qiu Jianfeng. Magnetic Resonance Imaging/Spectroscopy Quality Control Methods
1 Scope
China's national quality control method for magnetic resonance imaging and spectrometry systems. An MRI scanner degrades in ways that are invisible in the images it produces until they are severe: the main field drifts and loses homogeneity, the gradient calibration shifts so that distances in the image are wrong, the radiofrequency coils lose sensitivity unevenly, and the signal to noise ratio falls. None of that announces itself - the images still look like images - and a radiologist reading them has no way to know. So the machine is tested periodically against a phantom of known geometry and composition, and the measurements are tracked over time: geometric accuracy, slice thickness and position, spatial resolution, image uniformity, signal to noise, and ghosting. The value is in the trend rather than the absolute figure, which is why the method has to be repeatable enough that a change means something.
This document establishes the principles of quality control (hereinafter referred to as "QC") methods for imagers and spectrometers based on the magnetic resonance principle and describes The measurement conditions, measurement equipment, control process, data processing and other contents of magnetic resonance imaging/spectroscopy quality control methods are discussed. This document applies to the quality control, design, production, and batch verification of magnetic resonance imaging/spectroscopy in the fields of medicine and life sciences. It is used as a reference for quality control in inspection and other links.
2 Normative references
This document has no normative references.
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Using the characteristics of atomic nucleus spin motion, in an external magnetic field, after being excited by radio frequency pulses, a signal is generated, which is detected by a detector and then processed. A measuring instrument that displays images after mathematical conversion.
3.2 Nuclear Magnetic Resonance Spectrometer An instrument for measuring material spectra using nuclear magnetic resonance (NMR) technology. Note
1.In a strong magnetic field, the energy level of the atomic nucleus splits. When absorbing external electromagnetic radiation, the nuclear energy level transition will occur. Capturing this signal can obtain the corresponding The spectrum of the child. Note
2.This document relates to imaging nuclear magnetic resonance spectrometers associated with nuclear magnetic resonance imagers, which use their high-precision relaxation time measurements to achieve Calibration of magnetic resonance imaging equipment.
3.3 protondensity The amount of protons of a certain element per unit volume.
Note. When other parameters remain unchanged, the magnetic resonance signal intensity is proportional to the proton density.
3.4 The synthetic magnetization vector generated by the spin of the atomic nucleus in the magnetic field is stimulated by the radio frequency signal to form Larmor precession. The time it takes for the component of the synthetic magnetization vector about its spin axis (Z axis) to change to its initial state (before applying the RF signal) after the signal is removed.
Note. The component of the synthetic magnetization vector on its spin axis (Z axis) is restored to 1- e to determine the longitudinal relaxation time value.
3.5 The synthetic magnetization vector generated by the spin of the atomic nucleus in the magnetic field is stimulated by the radio frequency signal to form Larmor precession.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 25 pages — is available in the English PDF.
How to Buy GB/T 43688-2024
- 1Add to cart. Click the "Buy GB/T 43688-2024" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 47310-2026 — Determination of total silicon, aluminium, iron, potassium, sodium, calcium, magnesium, manganese, phosphorus, titanium and sulfur in soil - Monochromatic excitation energy dispersive X-ray fluorescence spectrometry
GB/T 47321-2026 — Specification for the warning data exchange of the national emergency early warning dissemination system
GB/T 47293-2026 — Determination of available mercury in soil
Secure payment via Stripe
Payments accepted
GB/T 43688-2024
$360.00