Scope

GB/T 35772-2017 is the English-translated version of 聚氯乙烯制品中邻苯二甲酸酯的快速检测方法 红外光谱法.

GB/T 35772-2017 is the Chinese standard "Rapid detection of phthalate esters in polyvinyl chloride products - Infra-red spectrometric method".

Its scope clause reads: This standard specifies the principle of using infrared spectroscopy to quickly detect phthalate plasticizers in PVC products, reagents and materials, Equipment, qualitative screening, quantitative analysis and calculation of results This standard applies to the total content of phthalates not less than 1% of the qualitative and quantitative detection of PVC materials.

Its clauses include principle; reagents and materials; equipment; qualitative screening.

Found what you need?

Document preview — GB/T 35772-2017

National Standard of the People's Republic of China

ICS
83.040.30
Classification
G 31

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 principle
  • 4 Reagents and materials
  • 5 equipment
  • 6 qualitative screening

1 Scope

This standard specifies the principle of using infrared spectroscopy to quickly detect phthalate plasticizers in PVC products, reagents and materials,

Equipment, qualitative screening, quantitative analysis and calculation of results

This standard applies to the total content of phthalates not less than 1% of the qualitative and quantitative detection of PVC materials.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 6040-2002 General rules of infrared spectrometry

3 principle

Preparing a series of standard samples containing phthalate plasticizers, using infrared spectrometer to collect the infrared spectrum data of the standard, according to the standard red

Partial Least Squares (PLS) stoichiometry model was established for the characteristic peaks of external spectra, and then the infrared spectra of unknown samples were scanned.

1580cm-1 and 1600cm-1 ring skeleton characteristic absorption peak qualitative analysis, and then using the stoichiometric model of unknown samples of o-benzene two

Formate plasticizer total content.

4 Reagents and materials

4.1

Phthalate standards Purity >=98%, see Appendix A.

4.2

Non-phthalate plasticizers Dioctyl terephthalate (DOTP) and trioctyl trimellitate (TOTM), purity >=97%.

4.3

standard sample with polyvinyl chloride (PVC) resin.

4.4 Tetrahydrofuran (THF)

Spectral purity.

5 equipment

5.1

Fourier transform infrared spectrometer in line with the provisions of GB/T 6040-2002 4.2.1.

5.2 Attenuated Total Reflection (ATR) Accessories

The test crystal is germanium (Ge) crystal.

5.3 Analytical balance

Accuracy of 0.01mg.

5.4

Drying oven temperature fluctuations ± 2 °C.

6 qualitative screening

6.1 sample preparation

Take a flat surface of the test sample, so that it can be close to the ATR attachment crystal surface.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 35772-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 35772-2017

$145.00