GB/T 35762-2017Textiles—Test method for thermal transmittance—Flat plate test (English PDF)
纺织品 热传递性能试验方法 平板法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 35762-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 29, 2017
Implementation date
July 1, 2018
Scope
GB/T 35762-2017 is the English-translated version of 纺织品 热传递性能试验方法 平板法.
GB/T 35762-2017 is the Chinese standard "Textiles -- Test method for thermal transmittance -- Flat plate test". Its scope clause reads: This Standard specifies the test method for the thermal transmittance of textiles.
This Standard applies to all types of textile fabrics and their products. Coated fabrics, leather, and multi-layer composite materials can refer to this Standard for implementation.
Its clauses include terms and definitions; principle; instruments; humidity control and test atmosphere; specimens; test procedure; calculation results; test report.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on DECEMBER 29, 2017 and took effect on JULY 01, 2018.
Found what you need?
Document preview — GB/T 35762-2017
National Standard of the People's Republic of China
- ICS
- 59.080.30
- Classification
- W 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions4
- 4 Principle5
- 5 Instruments5
- 6 Humidity control and test atmosphere7
- 7 Specimens7
- 8 Test procedure8
- 9 Calculation results8
- 10 Test report9
- Annex A (informative) Calculation formulas for thermal resistance and insulation rate10
1 Scope
This Standard specifies the test method for the thermal transmittance of textiles.
This Standard applies to all types of textile fabrics and their products. Coated fabrics, leather, and multi-layer composite materials can refer to this Standard for implementation.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 6529, Textiles -- Standard atmospheres for conditioning and testing
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 Thermal resistance
The ratio of the temperature difference between the two sides of the specimen to the heat flow per unit area passing vertically through the specimen.
NOTE 1: The dry heat flow may be in the form of one or more of conduction, convection, and radiation.
NOTE 2: The thermal resistance Rct is measured in square meters Kelvin per watt (m2·K/W).
3.2 Heat transmission coefficient
The heat flux per unit area of the specimen when there is a unit temperature difference between the two sides of the specimen, expressed in W/(m2·K).
3.3 Clo value
A unit of thermal resistance. When a person sitting still (with a basal metabolic rate of 58 W/m²) feels comfortable in an environment with a temperature of 21°C, a relative humidity not exceeding 50%, and an airflow not exceeding 0.1 m/s, the thermal insulation value of the clothing they wear is 1 clo.
4 Principle
Place the specimen on a test plate. The test plate, base plate, and surrounding protective plate are all electrically controlled to maintain a constant temperature. Heat from the test plate is dissipated only in the direction of the specimen. Measure the heating power required to maintain the constant temperature of the test plate for a given period of time.
Calculate the thermal resistance, heat transmission coefficient, and clo value of the specimen.
5 Instruments
5.1 Hot plate
The hot plate assembly consists of a test plate, a protective plate, and a base plate (see Figure 1). Each plate can be maintained at a constant temperature of (35±0.1)°C after heating.
The test plate is part of the hot plate. It shall be at least 0.04 m² (e.g., a square with each side at least 200 mm). It shall be placed in the center of the top surface of the hot plate assembly. The test plate is typically made of aluminum or copper.
The protective plate surrounds the test plate in a circular pattern. Its width, b, shall be at least 60 mm. Its thickness and composition shall be identical to those of the test plate and coplanar with the plate. The two plates are insulated with approximately 3 mm wide strips of cork or other insulating material. The protective plate prevents lateral heat loss from the test plate.
The bottom plate has the same thickness and composition as the test plate and protective plate. It is parallel to the test plate and protective plate. A certain distance (e.g., 25 mm~75 mm) is maintained to create an air chamber between the upper and lower plates.
The bottom plate prevents heat loss downward from the test plate and protective plate.
5.2 Temperature detection and controller
The test plate, protective plate, and base plate shall each have a temperature sensor and temperature controller. The sensor probes shall be placed inside the plate, as close as possible to the outer surface, to measure the surface temperature. The temperature controller shall maintain a constant temperature on each plate with an accuracy of ±0.1°C.
5.3 Thermal power meter
The heating power of the test plate shall be determined using an appropriate device with an accuracy of ±2%.
5.4 Instrument cover
Place it above the hot plate. See Figure 2 for a schematic diagram of the instrument cover and hot plate positions. The wind speed inside the cover shall not exceed 0.1 m/s.
6 Humidity control and test atmosphere
It shall be implemented in accordance with the provisions of standard atmosphere in GB/T 6529.
7 Specimens
7.1 Cut 3 specimens from each sample. The specimens shall be large enough to cover both the test plate and the protective plate. The specimens must be flat and wrinkle-free.
7.2 The sample shall be placed in the specified standard atmospheric conditions and humidified until it reaches equilibrium.
7.3 Or prepare and adjust the humidity of the specimen in accordance with the agreement between the parties concerned. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- GB/T 21294-2024Testing Methods of Physical and Chemical Performance of Garments
- FZ/T 64087-2022Wadding of kapok fiber
- GA 311-2021Police shoes - Cotton-padded leather shoes for men
- GA 312-2021Police shoes - Cotton-padded leather shoes for women
- GA 311-2010Police shoes - Cotton-padded leather shoes for men
- GA 312-2010Police shoes - Cotton-padded leather shoes for women
Similar standards
How to Download GB/T 35762-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6529-2008 — Textiles - Standard atmospheres for conditioning and testing
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 35762-2017
$150.00