Scope
GB/T 35710-2017 is the English-translated version of 35kV及以下电压等级电力变压器容量评估导则.
GB/T 35710-2017 is the Chinese standard "Rated power evaluation guide for 35kV and below power transformers". Its scope clause reads: This standard specifies the 35kV and below the voltage level of power transformer capacity testing conditions, testing programs, assessment processes and assessment method.
This standard applies to the assessment of 35kV and below voltage level power transformers (excluding high voltage transformers and other special transformers) whether Meet the standard GB/T 6451, GB/T 10228, GB/T 22072, GB/T 25289, GB/T 25438, GB/T 25446 standard standard The amount of sequence. Its clauses include terms and definitions, symbols.
Found what you need?
Document preview — GB/T 35710-2017
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K 41
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions, symbol
- 3.1 Terms and definitions
- 3.2 Symbol
- 4 test
- 4.1 Test conditions
- 4.2 test items
- 5 Evaluation
- 5.1 Assessment Process
- 5.2 Assessment Method
- Appendix A (informative) power transformer capacity evaluation record format
- Appendix B (informative) Power transformer capacity evaluation example
1 Scope
This standard specifies the 35kV and below the voltage level of power transformer capacity testing conditions, testing programs, assessment processes and assessment method.
This standard applies to the assessment of 35kV and below voltage level power transformers (excluding high voltage transformers and other special transformers) whether
Meet the standard GB/T 6451, GB/T 10228, GB/T 22072, GB/T 25289, GB/T 25438, GB/T 25446 standard standard
The amount of sequence.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 1094.1 Power Transformers Part 1. General
GB/T 1094.2 Power transformers - Part 2. Temperature rise of liquid immersed transformers
GB/T 1094.11 Power transformers - Part 11. Dry-type transformers
Electrotechnical terminology transformers, voltage regulators and reactors GB/T 2900.95-2015
GB/T 6451 oil-immersed power transformer technical parameters and requirements
GB/T 10228 dry-type power transformers technical parameters and requirements
GB/T 22072 dry amorphous alloy core distribution transformers technical parameters and requirements
GB/T 25289 Technical parameters and requirements for 20kV oil-immersed distribution transformers
GB/T 25438 three-phase oil-immersed three-dimensional wound core distribution transformers technical parameters and requirements
GB/T 25446 oil-immersed amorphous alloy core distribution transformers technical parameters and requirements
JB/T 501 Power Transformer Test Guidelines
3 Terms and definitions, symbols
3.1 Terms and definitions
GB/T 2900.95-2015 and GB/T 1094.1 as defined by the following terms and definitions apply to this document. For ease of use
With the repetition below lists some of the terms and definitions in GB/T 2900.95-2015.
3.1.1 Rated power
The specified value of apparent power marked on the winding together with the rated voltage of the winding determines its rated current.
Note 1. Rewrite GB/T 2900.95-2015, the definition of 2.1.3.
Note 2. The two windings of a two-winding transformer have the same rated capacity, so by definition it is the rated capacity of the transformer.
3.1.2 Default capacity assumedratedpower
Power transformer capacity to determine the flow of the rated capacity of the default value.
Note. The first time you can set the nameplate capacity.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 35710-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 35710-2017
$235.00