Valid

GB/T 35708-2017Testing method of fault location system in plateau distribution network (English PDF)

高原型配电网故障定位系统检验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (30 pages)

Need quotation for your management?

Get a formal quotation for GB/T 35708-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 29, 2017

Implementation date

July 1, 2018

Scope

GB/T 35708-2017 is the English-translated version of 高原型配电网故障定位系统检验方法.

GB/T 35708-2017 is the Chinese standard "Testing method of fault location system in plateau distribution network". Its scope clause reads: This standard specifies the plateau distribution network fault location system test methods, test items and inspection rules.

This standard applies to altitude above 1000m to 5000m plateau region, the rated voltage of 10kV distribution network. 1000m above sea level And the following areas can be implemented by reference.

Distribution network with rated voltage of 6kV to 35kV beyond 10kV can be implemented by reference. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 35708-2017

National Standard of the People's Republic of China

ICS
29.260.01
Classification
K 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 test methods
  • 5 inspection rules
  • Appendix A (normative) the main function and technical requirements
  • Appendix B (normative) pilot project

1 Scope

This standard specifies the plateau distribution network fault location system test methods, test items and inspection rules.

This standard applies to altitude above 1000m to 5000m plateau region, the rated voltage of 10kV distribution network. 1000m above sea level

And the following areas can be implemented by reference.

Distribution network with rated voltage of 6kV to 35kV beyond 10kV can be implemented by reference.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 2423.1 Environmental testing for electric and electronic products Part 2. Test methods Test A. Low temperature

GB/T 2423.2 Environmental testing for electric and electronic products Part 2. Test methods Test B. High temperature

GB/T 2423.4-2008 Environmental testing for electric and electronic products Part 2. Test methods Test Db. Alternating hot and humid (12h

12h cycle)

GB/T 2423.8 Environmental testing for electric and electronic products Part 2. Test methods Test Ed. Free fall

GB/T 4208 enclosure protection (IP code)

GB/T 5169.10-2006 Fire hazard testing for electrician and electronic products - Part 10. Basic test methods for glow/hot wire

Hot wire installations and common test methods

GB/T 5169.11-2006 Fire hazard testing for electric and electronic products Part 11 - Glow/hot wire basic test methods into

Glowing wire flammability test methods

GB/T 11287-2000 Electrical relays - Part 21. Vibration, shock, bump and earthquakes of measuring relays and protection devices

Test Part 1. Vibration test (sine)

Shock and collision tests for measuring relays and protection equipment

GB/T 17626.2 Electromagnetic compatibility test and measurement techniques Electrostatic discharge immunity test

GB/T 17626.3 Electromagnetic compatibility testing and measurement techniques RF electromagnetic field immunity test

GB/T 17626.4 Electromagnetic compatibility test and measurement techniques fast transient burst immunity test

GB/T 17626.5 electromagnetic compatibility test and measurement techniques surge (impact) immunity test

GB/T 17626.8 Electromagnetic compatibility test and measurement techniques Power frequency magnetic field immunity test

GB/T 17626.10 Electromagnetic compatibility (EMC) - Testing and measurement techniques - Damped oscillatory magnetic field immunity test

GB/T 17626.11 electromagnetic compatibility test and measurement techniques voltage dips, short interruptions and voltage variations immunity test

GB/T 17626.12 Electromagnetic compatibility Testing and measurement techniques Ringing wave immunity test

Transformers GB/T 20840.3-2013 Part 3. Electromagnetic voltage transformer supplementary technical requirements

Transformers - Part 7. Electronic voltage transformers

3 Terms and definitions

The following terms and definitions apply to this document.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Similar standards

How to Download GB/T 35708-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 35708-2017

$600.00