Valid

GB/T 35665-2017Determination of formate and acetate in the wet precipitation—Ion chromatography (English PDF)

大气降水中甲酸根和乙酸根离子的测定 离子色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 35665-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 29, 2017

Implementation date

July 1, 2018

Scope

GB/T 35665-2017 is the English-translated version of 大气降水中甲酸根和乙酸根离子的测定 离子色谱法.

GB/T 35665-2017 is the Chinese standard "Determination of formate and acetate in the wet precipitation—Ion chromatography".

Its scope clause reads: This standard specifies the measurement principle of ionic exchange chromatography for the determination of formate and acetate ion precipitation, reagents, instruments and Utensils, sample collection and preservation, measurement procedures, analysis results, analysis of quality control and evaluation.

This standard applies to the determination of formate and acetate ion concentrations in atmospheric precipitation samples. Its clauses include terms and definitions; measurement principle.

Found what you need?

Document preview — GB/T 35665-2017

National Standard of the People's Republic of China

ICS
07.060
Classification
A 47

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 measurement principle
  • 5 Reagents
  • 5.1 Deionized water
  • 5.2 standard solution
  • 5.3 test solution
  • 5.4 Eluent
  • 5.5 Regeneration solution
  • 6 instruments and utensils
  • 6.1 Ion Chromatography
  • 6.2 Vessel
  • 7 sample collection and preservation
  • 8 Measurement Step
  • 8.1 Preheat the instrument
  • 8.2 calibration curve production
  • 8.3 Precipitation Sample Analysis
  • 8.4 Analysis of quality inspection
  • 10 Analysis Quality Control and Assessment
  • 10.1 Basic Requirements
  • 10.2 Stability Test
  • 10.3 Precision Assessment
  • 10.4 Accuracy Assessment
  • 10.5 Spike recovery rate assessment
  • 10.6 Blind test
  • 10.7 Dilution Assessment
  • 10.8 Evaluation Report
  • Appendix A (Normative) Interference and elimination
  • Appendix B (Informative) Formate and acetate ion analysis uncertainty of the results of the assessment report

1 Scope

This standard specifies the measurement principle of ionic exchange chromatography for the determination of formate and acetate ion precipitation, reagents, instruments and

Utensils, sample collection and preservation, measurement procedures, analysis results, analysis of quality control and evaluation.

This standard applies to the determination of formate and acetate ion concentrations in atmospheric precipitation samples.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 13580.2 collection and preservation of atmospheric precipitation samples

General principles of JY/T 020 ion chromatography

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Standard stock solution

Concentrations are known and can be suitable for a long time (greater than or equal to 1 month) storage and access solution.

3.2 Test solution

Used to participate in the analysis along with the sample to test solutions of known concentration for analysis of system stability.

3.3 Eluents

The ion-adsorbed ion-exchange column can be rinsed out of the solution.

3.4 Regeneration liquid

The ion exchange column to restore the original surface chemical properties of the solution.

4 measurement principle

Determination of formate and acetate by ion chromatography is the use of ion exchange principle of formate, acetate and other anion anion

The inhibition column was used to subtract the background conductance of the eluent and then the conductivity detector was used for the determination. According to the standard solution of formate and acetate

The retention time and peak area (or peak height) of an ion peak can be used to quantify formate and acetate ions in a sample.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 35665-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 35665-2017

$205.00