Valid

GB/T 34926-2017Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1kV (English PDF)

额定电压0.6/1kV及以下云母带矿物绝缘波纹铜护套电缆及终端

Preview PDF

This is a limited preview

Buy now to download the full PDF (32 pages)

Need quotation for your management?

Get a formal quotation for GB/T 34926-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

November 1, 2017

Implementation date

May 1, 2018

Scope

GB/T 34926-2017 is the English-translated version of 额定电压0.6/1kV及以下云母带矿物绝缘波纹铜护套电缆及终端.

GB/T 34926-2017 is the Chinese standard "Corrugated copper metallic sheath mica tape mineral insulated cables and their terminations with a rated voltage up to and including 0.6/1kV".

Its scope clause reads: This standard specifies the terms and definitions mica with mineral insulated ripple copper sheathing cables and terminations rated voltage 0.6/1kV and below, points Classes, Codes, Models, Specifications and Markings, Characteristics of Use, Technical Requirements, Tests, Inspection Rules, Signs and Labels, Packaging, Transport and Storage.

This standard applies to the rated voltage 0.6/1kV susceptible to the spread of fire or direct impact of fire and other places for power transmission with the mica tape Mineral insulated corrugated copper sheathed power cables and terminals, and the rated voltage 450/750V susceptible to the spread of fire or fire directly affect the field Controlled, monitoring circuit and the protection of mica cable with mineral insulated ripple copper sheath control cables and terminals.

Found what you need?

Document preview — GB/T 34926-2017

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K 13

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 classification, code, specifications and markings, the use of features
  • 5 technical requirements
  • 6 Test conditions
  • 7 routine test
  • 8 sampling test
  • 10 Non-electrical type test
  • 11 terminal
  • 12 Inspection Rules
  • 13 logos and labels
  • 14 Packaging, transport and storage
  • Appendix B (Normative) Mica tape performance
  • Appendix C (Informative) Low-smoke halogen-free flame retardant tape performance
  • Appendix D (informative) cable reference diameter
  • Appendix E (Informative) Cable Terminal Schematic
  • Appendix F (normative) numerical repair about
  • References

1 Scope

This standard specifies the terms and definitions mica with mineral insulated ripple copper sheathing cables and terminations rated voltage 0.6/1kV and below, points

Classes, Codes, Models, Specifications and Markings, Characteristics of Use, Technical Requirements, Tests, Inspection Rules, Signs and Labels, Packaging, Transport and Storage.

This standard applies to the rated voltage 0.6/1kV susceptible to the spread of fire or direct impact of fire and other places for power transmission with the mica tape

Mineral insulated corrugated copper sheathed power cables and terminals, and the rated voltage 450/750V susceptible to the spread of fire or fire directly affect the field

Controlled, monitoring circuit and the protection of mica cable with mineral insulated ripple copper sheath control cables and terminals.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

Copper and copper alloy strip

GB/T 2900.10 Electrotechnical terminology cables

GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 11. Thickness of common test methods

Mechanical and performance tests on dimensions and dimensions

GB/T 3048.4-2007 wire and cable electrical performance test methods - Part 4 DC conductor resistance test

GB/T 3048.5-2007 wire and cable electrical performance test methods Part 5. Insulation resistance test

GB/T 3048.8-2007 Electrical wire and cable test methods - Part 8. AC voltage test

Conductor for GB/T 3956-2008 cables

Mica - based insulating materials - Part 2. Test methods

GB/T 6995.3-2008 wire and cable Identification Marking Methods Part 3. Wire and Cable Identification Mark

GB/T 6995.5-2008 wire and cable identification methods - Part 5. Power cable insulated core identification mark

Plastic insulated control cables - Part 1. General provisions

GB/T 12706.1-2008 Rated voltage 1kV (Um = 1.2kV) to 35kV (Um = 40.5kV) extruded insulated power cables

And accessories Part 1. Rated voltage 1kV (Um = 1.2kV) and 3kV (Um = 3.6kV) cable

GB/T 17650.2-1998 Test methods for the release of gases on combustion of materials from cables or cables - Part 2. Measurement with pH and conductivity to determine the gas acidity

General rules of flame-retardant and fire-resistant wire and cable GB/T 19666-2005

Tobacco toxicity toxicity classification according to GB/T 20285-2006

High Voltage Cable Selection Guide

YS/T 649 copper and copper alloy rod

Insulating hoses - Part 2. Insulating hoses (Flexibleinsulatingsleeving - Part 2.

Methodsoftest)

BS6387.2013 Fire conditions in the cable line integrity test fire test method (Testmethodforresistanceto fireofcablesrequiredtomaintaincircuitintegrityunderfireconditions)

BS8491.2008 fire-resistant integrity of large-diameter power cables used as components of smoke and heat control systems and other active fire safety systems […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 32 pages — is available in the English PDF.

Similar standards

How to Download GB/T 34926-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
32 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 34926-2017

$480.00