GB/T 34873-2017Vacuum gauges -- Calibration by direct comparison with a reference gauge (English PDF)

真空计 与标准真空计直接比较校准

Preview PDF

This is a limited preview

Buy now to download the full PDF (13 pages)

Need quotation for your management?

Get a formal quotation for GB/T 34873-2017 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Level / Type

National · Recommended

Issue date

November 1, 2017

Implementation date

May 1, 2018

Scope

GB/T 34873-2017 is the English-translated version of 真空计 与标准真空计直接比较校准.

GB/T 34873-2017 — This standard specifies the vacuum gauge and the standard vacuum gauge directly compare the calibration to meet the physical, technical and measurement conditions.

Pass on these bars the description of the piece can deduce the design of a device that can be used to calibrate a vacuum gauge. School vacuum gauge can be any type.

Many types of gauges consist of several sections, primarily. gauges, cables, instrumentation, and communications no. read the instrument. This whole part can be regarded as a unit to be calibrated.

Thus, if only regulatory (ie, the vacuum gauge is directly exposed to true Empty part of the environment) to calibrate, then you can record all the settings and conditions, so that the regulation of the user can use and calibration Measure in the same way.

The standard vacuum gauge is also a calibrated vacuum gauge that is traceable to vacuum primary or national standards (usually) with a compliance GB/T 27025-2008 calibration certificate required or traceable to the SI system and can determine the measurement uncertainty of absolute measurement instruments (A few cases).

This standard on how to deal with a special type of vacuum gauge did not guide, whether it is standard vacuum gauge or gauge, such guidance will be in Available in other standards.

The calibration pressure range discussed in this standard depends on the actual design of the calibration device and the type of standard vacuum gauge. Calibration range at 10-6Pa ~ 110kPa between the changes.

Found what you need?

Document preview — GB/T 34873-2017

National Standard of the People's Republic of China

ICS
23.160
Classification
J 78

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China, Standardization Administration of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Symbols and abbreviations
  • 5 General
  • 6 Requirements
  • 6.1 Calibration Room Design
  • 6.2 Vacuum gauge and calibration room to connect the pipeline
  • 6.3 Vacuum and air intake system
  • 6.4 Calibration gas
  • 6.5 Thermometer and indoor conditions
  • 6.6 Standard vacuum gauge
  • 7 Calibration
  • 7.1 Step
  • 7.2 Measurement results evaluation
  • 7.3 Measurement Uncertainty
  • 8 Calibration certificate
  • Appendix A (Informative) Example of a Possible Calibration System
  • Appendix B (Informative) Problems in Actual Calibration
  • Reference

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard uses the translation method identical with ISO 3567:2011 "vacuum gauge and standard vacuum gauge direct comparison and calibration." this standard is proposed by the China Machinery Industry Federation.

This standard by the National Vacuum Technology Standardization Technical Committee (SAC/TC18) centralized.

This standard drafting unit. China Aerospace Science and Technology Corporation Fifth Institute of the five hundred and eleven Institute, China Institute of Metrology, Hefei Zhihai Optoelectronics Technology Co., Ltd., Zhejiang Vacuum Equipment Group Co., Ltd., Hunan Weigang Magnetic Fluid Co., Ltd., Beijing North instrument innovation really Empty technology limited liability company, Dongguan Jin Sheng Precision Components Co., Ltd., Shenyang Institute of Vacuum Technology.

1 Scope

This standard specifies the vacuum gauge and the standard vacuum gauge directly compare the calibration to meet the physical, technical and measurement conditions. Pass on these bars the description of the piece can deduce the design of a device that can be used to calibrate a vacuum gauge.

School vacuum gauge can be any type. Many types of gauges consist of several sections, primarily. gauges, cables, instrumentation, and communications no. read the instrument. This whole part can be regarded as a unit to be calibrated. Thus, if only regulatory (ie, the vacuum gauge is directly exposed to true Empty part of the environment) to calibrate, then you can record all the settings and conditions, so that the regulation of the user can use and calibration Measure in the same way.

The standard vacuum gauge is also a calibrated vacuum gauge that is traceable to vacuum primary or national standards (usually) with a compliance GB/T 27025-2008 calibration certificate required or traceable to the SI system and can determine the measurement uncertainty of absolute measurement instruments (A few cases).

This standard on how to deal with a special type of vacuum gauge did not guide, whether it is standard vacuum gauge or gauge, such guidance will be in Available in other standards.

The calibration pressure range discussed in this standard depends on the actual design of the calibration device and the type of standard vacuum gauge. Calibration range at 10-6Pa ~ 110kPa between the changes.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 27025-2008 General Requirements for Testing and Calibration Laboratory Capabilities (ISO/IEC 17025:2005, IDT) ISO/IEC Guide 98-3, Measurement Uncertainty Part 3. Guidance on Measurement Uncertainty (GUM.1995) [Uncer-taintyofmeasurement-Part 3: Guidetotheexpressionofuncertaintyin measurement (GUM.

1995)]

3 Terms and definitions

The following terms and definitions apply to this document.

The original standard primarystandard Measurement standards established using a primary reference measurement procedure.

See ISO/IEC Guide 99.2007, 5.4, as amended.

National standard by the national authority certification, in a country or economy as the same amount of other measurement standards set value measurement standards.

[See ISO/IEC Guide 99.2007, 5.3] 3.3 Referencestandard Specify the measurement standard used to calibrate other measurement standards of the same type in the designated organization or designated area.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 13 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 34873-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
13 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 34873-2017

$215.00