GB/T 34845-2017Tissue paper—Determination of adsorbable organic halogen(AOX) (English PDF)
生活用纸 可吸附有机卤素(AOX)的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 34845-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 1, 2017
Implementation date
May 1, 2018
Scope
GB/T 34845-2017 is the English-translated version of 生活用纸 可吸附有机卤素(AOX)的测定.
GB/T 34845-2017 is the Chinese standard "Tissue paper -- Determination of absorbable organic halogen (AOX)". Its scope clause reads: This standard specifies the determination method for adsorbable organic halogens (AOX) in tissue paper.
This standard applies to the determination of AOX in tissues, toilet paper and other tissue papers. The detection limit of this standard is 2 mg/kg.
Its clauses include terms and definitions; principle; apparatus and equipment; reagents and materials; sampling and processing; test procedure; result calculation; inspection and calibration; test report.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on NOVEMBER 01, 2017 and took effect on MAY 01, 2018.
Found what you need?
Document preview — GB/T 34845-2017
National Standard of the People's Republic of China
- ICS
- 85.080
- Classification
- Y 30
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions4
- 4 Principle5
- 5 Apparatus and equipment5
- 6 Reagents and materials5
- 7 Sampling and processing6
- 8 Test procedure6
- 9 Result calculation7
- 10 Inspection and calibration7
- 11 Test report8
1 Scope
This standard specifies the determination method for adsorbable organic halogens (AOX) in tissue paper.
This standard applies to the determination of AOX in tissues, toilet paper and other tissue papers. The detection limit of this standard is 2 mg/kg.
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this standard.
GB/T 450 Paper and board - Sampling for testing and identification of machine and cross direction wire side and felt side
GB/T 462 Paper, board and pulp - Determination of moisture content of analytical sample
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Tissue paper
Crepe paper for sanitary wipes produced from wood fiber or non-wood fiber, including toilet paper, paper towels (paper napkins, paper face towels, paper handkerchiefs), hand tissues, kitchen paper towels, etc.
3.2 Adsorbable organic halogen; AOX
6 Reagents and materials
6.5 Electrolyte: Measure 75 mL of 98% glacial acetic acid; add water to make the volume to 100 mL.
6.6 Hydrochloric acid solution: 0.010 mol/L; measure 32.57 mL of 0.307 mol/L hydrochloric acid (density at 1.19 g/mL); add water to make the volume to 1 L.
6.7 p-chlorophenol stock solution: 200 µg/L; weigh 72.5 mg of p-chlorophenol; add water to make the volume to 100 mL.
6.8 Compressed gas: It is necessary to dilute oxygen with inert gas to control combustion during combustion. All gases used in the test shall not contain any form of chlorine and bromine.
6.4 Activated carbon: Dedicated for determination of adsorbable organic
halogen (AOX).
7 Sampling and processing
7.1 Sampling shall be carried out in accordance with the provisions of GB/T 450.
7.2 Test the moisture of the sample in accordance with the provisions of GB/T 462.
7.3 Preparation of the specimen: Use tweezers or scissors to tear or cut the sample into small pieces. Protective gloves shall be worn during specimen collection and preparation, to prevent contamination of the specimen.
8 Test procedure
8.1 Weigh 0.4 g ~ 0.6 g (accurate to 1 mg) of specimen. Put it into a 250 mL conical flask (5.4). Add 100 mL of sodium nitrate working solution (6.2). Close the stopper and shake the conical flask vigorously to make specimen is fully moistened. Then place it on the oscillator (5.2). Oscillate at a speed of 150 times/min for 1 h.
8.2 After oscillation, use the filter device (5.3) that has been installed in a clean quartz cup filter to filter the contents of the conical flask; use 25 mL of sodium nitrate working solution to rinse the conical flask and the inner wall of the filter.
Collect all the filtrate in a clean conical flask. Keep the filtrate A for later use.
8.3 Add 50 mg of activated carbon (6.4) to the filtrate A. Cap the flask tightly.
Then place it on the oscillator, to oscillate it at a speed of 150 times/min for 1 h.
8.4 Use a filter device to filter the contents of the conical flask to another clean quartz cup. Use 25 mL of sodium nitrate working solution to rinse the conical […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 34845-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 450-1989 — Paper and board--Sampling for testing
GB/T 450-2002 — Paper and board - Sampling for testing
GB/T 450-2008 — Paper and board -- Sampling for testing and identification of machine and cross direction, wire side and felt side
GB/T 34845-2017