GB/T 34035-2017Field test methods for thermocouples (English PDF)

热电偶现场试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 34035-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 31, 2017

Implementation date

February 1, 2018

Scope

GB/T 34035-2017 is the English-translated version of 热电偶现场试验方法.

GB/T 34035-2017 is the Chinese national standard on field test methods for thermocouples. It specifies the methods for testing a thermocouple assembly, including its compensating lead, before installation, after installation and after a period of service.

The purpose of the tests is to confirm that the assembly has not been damaged in storage or installation, that the polarity of the connections between the compensating conductor and the terminals is correct, and to provide reference data against which later tests can show whether the assembly has been damaged in use.

The variables measured after installation are loop resistance of the hot electrodes and of the compensating lead with the thermode, insulation resistance of the assembly insulation and between assembly and compensating lead, and thermoelectric power of the hot electrodes and of the compensating lead with the assembly.

Clause 3 defines junction type and detection circuit. Uniformity, capacitance and loop-current step-response tests are excluded because they need complex equipment and analysis, and some tests may not apply to particular types of thermocouple worked near the recommended temperature limits. It was issued on 31 July 2017 and has applied since 1 February 2018.

Found what you need?

Document preview — GB/T 34035-2017

National Standard of the People's Republic of China

ICS
17.200.20
Classification
N 11

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

Introduction

Thermocouples are widely used in industry and have high reliability when used within their specified temperature range. However, if in use out Now failure, the consequences can be light and heavy, and even threaten personal safety. In general, this may result in significant loss of equipment, product, or uptime. use The user should weigh the potential consequences of a thermocouple failure to determine which tests to make before and after thermocouple installation and during use.

This standard is intended for the thermocouple, thermocouple machine and the connecting wire guide to provide field testing to avoid the thermocouple in the storage, installation or Damage during use, not as a guide to acceptance testing.

The test method covers basic tests to ensure correct installation of the thermocouple, as well as some simple tests necessary for failure analysis. and Uniformity, capacitance and loop current step response thermocouple test, due to the need to be equipped with complex equipment and for complex analysis, in this standard No rules.

Normally produced thermocouple malfunctions, usually due to incorrect installation and operation outside the specified limits during use. These ones Most of the most common forms of fault conditions can be detected by using the test methods given in this standard.

When the thermocouple machine for the first time installed in the working environment should be the provisions of this standard test. However, these tests do not guarantee the thermocouple Function to accurately display the temperature. To ensure accuracy, the need to select the appropriate thermocouple and instrumentation, as well as measuring the temperature to select the appropriate test Points.

1 Scope

This standard specifies the method of testing the thermocouple machine, including the compensation wire, before and after installation, or after a period of use.

The purpose of the test is to ensure that the thermocouple machine is not damaged during storage or installation, compensating for the positive polarity of the connection between the conductor and the terminal Indeed, and for the future test evaluation thermocouple machine is damaged after use to provide reference data. Some of these tests may not apply to highs Specific types of thermocouples operating at the recommended limits of temperature.

This standard specifies the test, including the installation of thermocouple after measuring the following variables, and to determine whether the thermocouple machine is working In the damage to provide reference data.

--- Loop resistance.

- hot electrode;

- Compensation wire and thermode.

--- Insulation resistance.

- thermocouple machine insulation;

- thermocouple machine and compensation wire insulation.

--- Thermoelectric power.

- hot electrode;

- Compensation wire and thermocouple machine.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 4989-2013 Compensating lead for thermocouple

GB/T 25475-2010 Industrial automation instruments terminology temperature instruments

Industrial thermocouples

3 Terms and definitions

GB/T 25475-2010 defined and the following terms and definitions apply to this document.

3.1 Junction type junction class

Electrical continuity of the terminals of the thermocouple. For example, insulation type, grounding type and so on.

Insulated - Thermocouple Measurement terminals without electrical contact with the conductive protective sleeve or circuit reference ground.

Grounding type - Thermocouple Measurement end in direct electrical contact with a protective sleeve or box. [GB/T 25475-2010, definitions 2.5.60, 2.5.62 and 2.5.63]

3.2 Detection circuit sensing circuit

The sum of the thermode and compensation leads, but excluding signal conditioning components such as reference junction compensators, amplifiers, transmitters, and more.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 34035-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 34035-2017

$145.00