GB/T 33806-2017Technical requirement of area fluorescent imaging microarray scanner (English PDF)
面阵荧光成像微阵列芯片扫描仪技术要求
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 33806-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 31, 2017
Implementation date
December 1, 2017
Scope
GB/T 33806-2017 is the English-translated version of 面阵荧光成像微阵列芯片扫描仪技术要求.
GB/T 33806-2017 sets the technical requirements for area fluorescent imaging microarray scanners, the instruments that read a microarray chip by exciting it over its whole surface and photographing the fluorescence.
It covers the terms and definitions, the basic parameters, the requirements, the test methods and the inspection rules, together with the signs, labels and instructions and the packaging, transport and storage.
It applies to in vitro diagnostic medical devices that use a planar matrix as carrier and a CCD or CMOS detector, taking either a single shot or several. Its definitions fix what is meant by the scanner itself, by the microarray chip, by stability and by resolution.
It cites GB/T 191, GB 4793.1, GB/T 14710 and YY/T 0466.1. It was issued on 31 May 2017 and has applied since 1 December 2017.
Found what you need?
Document preview — GB/T 33806-2017
National Standard of the People's Republic of China
- ICS
- 11.040.55
- Classification
- C 30
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative reference documents
- 3 Terms and definitions
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the terms and definitions of the surface array fluorescence imaging microarray chip scanner (hereinafter referred to as the scanner), the basic parameters, requirements, Test methods, inspection rules, signs, labels and instructions, packaging, shipping and storage.
This standard applies to in vitro diagnostic medical devices, based on the plane matrix as the carrier, based on CCD (ChargeCoupledDevice, charge coupling Device) and a CMOS (ComplementaryMetal-Oxide Semiconductor) detector, One and multiple photographed face array fluorescence imaging microarray chip scanners.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 191 packaging and storage icon
GB 4793.1 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements
GB/T 14710 Environmental requirements and test methods for medical appliances
YY/T 0466.1 Symbols for medical devices for labeling, labeling and providing information on medical devices - Part 1: General requirements
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Face array fluorescence imaging microarray chip scanner area fluorescent imaging microarray scanner
The excitation light is converged on the surface of the microarray chip by an optical system, and the optical element is connected to the region The object to be measured is excited by the excitation light generated by the excitation light (fluorescence) to receive, imaging in the CCD (ChargeCoupledDevice, charge coupler ), CMOS (ComplementaryMetal-Oxide Semiconductor, and other array detectors)
On the photoelectric conversion, generate analog images or digital images and data files.
3.2 Microarray chip microarray
An array of microprocessors capable of arranging a plurality of pieces of information in a biological sample on a planar substrate carrier in an array manner.
3.3 Stability
Scanner on the microarray chip to be measured on the target detection signal strength of the ability to reproduce, in the basic to keep the target to send light signal intensity In the case of the same, it is possible to perform repeated operation for a long period of time and intermittent operation.
3.4 Resolution
Scanner on the microarray chip to be measured on the target size of the ability to identify the micro-array chip image can be used to identify the size of the smallest target Said.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB 4793.1Safety requirements for electrical equipment for measurement,control,andlaboratory use-Part 1:General requirements
- GB/T 14710The environmental requirement and test methods for medical electrical equipment
- YY/T 0466.1Medical devices - Symbols to be used with information to be supplied by the manufacturer - Part 1: General requirements
Similar standards
How to Download GB/T 33806-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 4793.1-1995 — Safety requirements for electrical equipment for measurement, control, and laboratory use. Part 1: General requirements
GB 4793.1-2007 — Safety requirements for electrical equipment for measurement,control,andlaboratory use-Part 1:General requirements
GB/T 14710-1993 — The environmental requirements and test methods for medical electrical equipment
GB/T 33806-2017
$145.00