GB/T 19665-2024 is the English-translated version of 红外成像人体表面测温筛查仪通用规范.
GB/T 19665-2024 is the general specification for infrared imaging instruments that measure and screen body surface temperature - the thermal cameras installed at station entrances, airports and building lobbies. They were deployed in enormous numbers in China after 2020, and the experience exposed how much of their apparent accuracy depended on things the specification had not pinned down: the blackbody reference in frame, the ambient temperature, the distance and angle to the subject, and the difference between skin temperature and core temperature. The standard sets the requirements on the basic composition, appearance and structure, dimensions and mass, functions, performance, interface compatibility, safety, environmental adaptability, electromagnetic compatibility, power supply adaptability and reliability, and then the corresponding test methods, inspection rules and marking, packaging, transport and storage provisions. It replaces GB/T 19665-2005 and took effect on 15 March 2024.
Document preview — GB/T 19665-2024
National Standard of the People's Republic of China
- ICS
- 11.040.55
- Classification
- N11
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and Definitions1
- 4 Requirements1
- 4.1 Basic composition1
- 4.2 Appearance and structure2
- 4.3 Dimensions and weight2
- 4.4 Function2
- 4.5 Performance3
- 4.6 Interface compatibility or cooperation4
- 4.7 Security4
- 4.8 Environmental adaptability5
- 4.9 Electromagnetic compatibility5
- 4.10 Power adaptability6
- 4.11 Reliability6
- 5 Experiment6
- 5.1 Test conditions6
- 5.2 Test methods6
- 6.1 General Provisions11
- 6.2 Identification and testing12
- 6.3 Quality consistency inspection13
- 7 Random Files15
- 7.1 General requirements15
- 7.2 User Manual Details15
- 8 Marking and storage15
- 8.1 Sign15
- 2 Inspection Items12
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part
1.Structure and drafting rules for standardization documents" Drafting. This document replaces GB/T 19665-2005 "General Specification for Electronic Infrared Imaging Human Surface Thermometers" and is compatible with GB/T 19665-2005 Compared with the previous version, in addition to structural adjustments and editorial changes, the main technical changes are as follows:
a) Added the terms and definitions of "standard boldface" and "reference source" (see
b) Deleted "Types and basic components of thermometers" (see Chapter 4 of the.2005 edition);
c) Added "Basic composition", "Appearance and structure", "Self-calibration function", "Screening function", "Display interface", "Storage and retrieval function" "Performance", "Temperature Measurement Consistency", "Temperature Screening False Alarm Rate", "Temperature Screening Missing Alarm Rate", "Average Alarm Response Time", "Maximum Screening Personnel flow", "continuous working time", "interface and compatibility or mutual cooperation", "power adaptability" requirements (see 4.1, 4.2, 4.4.2, 4.4.3, 4.4.4, 4.4.6, 4.5.4, 4.5.6, 4.5.7, 4.5.8, 4.5.9, 4.5.14,
d) Deleted "Image field cycle", "Focus function", "Temperature resolution", "Image file management function", "Medical record management function" "capability", "printing function", "trolley", "bracket", and "appearance" requirements (see 5.2.5, 5.2.7, 5.3.3, 5.4.2, 5.4.3, 5.5, 5.6,
e) Added the requirements for "Instruction Manual", "Packing List", "Correction Table and Diagram (optional)" and "Optional Documents" (see 7.1.1.1, 7.1.1.2, 7.1.1.3, 7.1.2);
f) "Labels and instructions for use" has been deleted (see Chapter 8 of the.2005 edition);
g) The requirements on storage environment temperature and humidity in "Storage" have been deleted (see
9.3 of the.2005 edition). Please note that some of the contents of this document may involve patents. The issuing organization of this document does not assume the responsibility for identifying patents. This document was proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This document is under the jurisdiction of the National Technical Committee for Standardization of Electronic Measuring Instruments (SAC/TC153). This document was drafted by: China Electronics Technology Group Corporation 11th Institute, China Electronics Technology Standardization Institute, Beijing Metrology Institute of Detection Science, Yantai Arrow Optoelectronics Technology Co., Ltd., Beijing Bopu Huaguang Technology Co., Ltd., China Aerospace Science and Industry Corporation Third Research Institute The 8358th Institute of the Chinese Academy of Sciences and Zhejiang Dahua Technology Co., Ltd. The main drafters of this document are. Yu Songlin, Liu Keyue, Wang Xiaoli, Cao Ce, Qi Haijun, Guo Fang, He Shaojie, Qiu Ying, Zhao Jinbo, Liu Yan, Ma Qun, Yuan Zhigang. The previous versions of this document and the documents it replaces are as follows:
---First published in.2005 as GB/T 19665-2005;
---This is the first revision. General specification for infrared imaging human surface temperature screening device
1 Scope
GB/T 19665-2024 is the general specification for infrared imaging instruments that measure and screen body surface temperature - the thermal cameras installed at station entrances, airports and building lobbies. They were deployed in enormous numbers in China after 2020, and the experience exposed how much of their apparent accuracy depended on things the specification had not pinned down: the blackbody reference in frame, the ambient temperature, the distance and angle to the subject, and the difference between skin temperature and core temperature. The standard sets the requirements on the basic composition, appearance and structure, dimensions and mass, functions, performance, interface compatibility, safety, environmental adaptability, electromagnetic compatibility, power supply adaptability and reliability, and then the corresponding test methods, inspection rules and marking, packaging, transport and storage provisions. It replaces GB/T 19665-2005 and took effect on 15 March 2024.
This document specifies the requirements, quality inspection rules, random documents and markings, packaging, storage, and other aspects of infrared imaging human surface temperature screening devices. et al., described the experimental method. This document applies to the production, inspection and acceptance of infrared imaging human surface temperature screening devices.
2 Normative references
The contents of the following documents constitute essential clauses of the document through normative references in this document. For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to This document.
GB/T 191-2008 Pictorial markings for packaging, storage and transportation
GB/T 6587-2012 General specification for electronic measuring instruments
GB/T 9969-2008 General principles for instructions for use of industrial products
GB/T 11463-1989 Reliability test for electronic measuring instruments
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 facetemperature Relying on passively receiving infrared information of the body's own thermal radiation, it is converted and processed into a visual image to obtain the measured body surface Temperature screening equipment.
Note. Abbreviated as "screener".
3.2 Standard black body The effective emissivity is approximately
1.It is used to measure the temperature accuracy, temperature repeatability and temperature uniformity of the screening instrument. The temperature is adjustable. Controlled metrological calibration equipment.
3.3 Reference source Calibration equipment used for real-time calibration of the temperature indication of the screening instrument and uniform radiation surface.
3.4 Over-temperature target A device that can release a specified amount of heat and is carried by the test person and can be recognized by the screener as exceeding normal body temperature.
4 Requirements
4.1 Basic composition The screening device should at least include an imaging unit, a display and control unit, and a support unit, and may also include a tracking and indication unit, a calibration unit, etc.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Buy GB/T 19665-2024
- 1Add to cart. Click the "Buy GB/T 19665-2024" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6587-2012 — General specification for electronic measuring instruments
GB/T 9969-2008 — General principles for preparation of instructions for use of industrial products
GB/T 47310-2026 — Determination of total silicon, aluminium, iron, potassium, sodium, calcium, magnesium, manganese, phosphorus, titanium and sulfur in soil - Monochromatic excitation energy dispersive X-ray fluorescence spectrometry
Secure payment via Stripe
Payments accepted
GB/T 19665-2024
$400.00