Scope
GB/T 33709-2017 is the English-translated version of 移动实验室 仪器设备量值溯源与传递指南.
GB/T 33709-2017 guides the traceability and the transfer of the value of the measuring equipment carried in a mobile laboratory.
It gives the general requirements, the traceability requirements and the value transfer requirements, then the methods and the sources used to obtain traceability and value transfer for mobile laboratory equipment, and finally how that work is managed.
Clause 3 repeats the terms it needs from JJF 1001-2011: calibration, verification, reference material, dissemination of the value of a quantity and metrological traceability.
The standard applies to drawing up and managing the technical requirements and methods for the traceability and the value transfer of mobile laboratory equipment. Issued on 12 May 2017, it has applied since 1 December 2017.
Found what you need?
Document preview — GB/T 33709-2017
National Standard of the People's Republic of China
- ICS
- 17.020
- Classification
- A 00
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 normative reference document
- 3 Terms and definitions
- 4 requirements
- 4.1 General requirements
- 4.2 traceability requirements
- 4.3 Value transfer requirements
- 5 Method and source of traceability and delivery of mobile laboratory equipment
- 6 Mobile laboratory equipment value traceability and delivery management
Foreword
This standard is drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the overall requirements of the traceability and transmission of the value of mobile laboratory equipment, the traceability method and technology of instrument and equipment Claim.
This standard applies to the development and management of the technical requirements and methods of traceability and delivery of mobile laboratory equipment.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
JJF 1001-2011 Standard terminology and definitions
3 Terms and definitions
The terms and definitions defined in JJF 1001-2011 apply to this document. For ease of use, some of the terms and definitions of JJF 1001-2011 are repeated below.
3.1 Calibration
The first step in determining a set of operations under the specified conditions is to determine the relationship between the magnitude provided by the measurement criteria and the corresponding indication, and the second step It is determined by this information from the indication to obtain the relationship between the measurement results, where the measurement standard to provide the amount and the corresponding indication has a measurement error Fixed degree. [JJF 1001-2011, definition 4.10]
3.2 Verification
Identify and confirm activities that meet the statutory requirements of the measuring instrument, including inspection, marking and/or certification. [JJF 1001-2011, definition 9.17]
3.3 Reference material (RM)
Substances with sufficient uniformity and stability, and their properties are proven to be suitable for use in measurement or in nominal characterization use. [JJF 1001-2011, definition 8.14]
3.4 Dissemination of the value of a quantity
By calibrating or verifying the measuring instrument, the unit value achieved by the national measurement standard is passed to each level of measurement Work to measure the activity of the instrument to ensure that the measured values are accurate and consistent. [JJF 1001-2011, definition 9.60]
3.5 Metrological traceability
Through the uninterrupted calibration chain specified in the document, the measurement results are related to the reference object.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 33709-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
JJF 1001-2011 — General Terms in Metrology and Their Definitions
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
Secure payment via Stripe
Payments accepted
GB/T 33709-2017
$85.00