GB/T 33584.6-2017Seawater quality requirements and analysis methods for seawater cooling system—Part 6: Determination of heterotrophic bacteria (English PDF)
海水冷却水质要求及分析检测方法 第6部分:异养菌的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 33584.6-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 12, 2017
Implementation date
December 1, 2017
Scope
GB/T 33584.6-2017 is the English-translated version of 海水冷却水质要求及分析检测方法 第6部分:异养菌的测定.
GB/T 33584.6-2017 is Part 6 of GB/T 33584 and covers the seawater quality required by a seawater cooling system together with the plate count method for the heterotrophic bacteria in the cooling water.
It gives the principle, the reagents and materials, the instruments and equipment, the analysis and determination, the counting of the colonies and the way the total colony count is calculated and reported, and it defines heterotrophic bacteria, the colony forming unit and the spreading colony.
It applies to seawater cooling water and also to raw seawater. The method collects a water sample directly instead of using a slime collecting device, which shortens sampling and preparation.
Clause 2 cites GB/T 6682 on water for analytical laboratory use. It was issued on 12 May 2017 and has applied since 1 December 2017.
Found what you need?
Document preview — GB/T 33584.6-2017
National Standard of the People's Republic of China
- ICS
- 07.060; 13.060
- Classification
- Z 17
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative reference documents
- 3 Terms and definitions
- 4 Water quality requirements
Foreword
GB/T 33584 "seawater cooling water quality requirements and analysis of detection methods" is divided into six parts.
- Part 1: Determination of calcium and magnesium ions;
- Part 2: Determination of zinc;
- Part 3: Determination of chlorides;
- Part 4: Determination of sulphate;
- Part 5: Determination of dissolved solids;
- Part 6: Determination of heterotrophic bacteria.
This part is Part 6 of GB/T 33584.
This part is drafted in accordance with the rules given in GB/T 1.1-2009. This section is presented by the State Oceanic Administration.
This part is headed by the National Marine Standardization Technical Committee (SAC/TC283).
Introduction
In the sea water as the water source of the water cooling system is easy to breed microbial dirt deposition and other hazards, therefore, in the process of running the system often The amount of microbial biomass is to be used to assess the degree of biological contamination of the system and the effectiveness and economy of the biocontrol technology used, most of which Often measured the total number of mucus-forming bacteria. But in the mucus-forming bacteria in the determination process, the need to use a complete set of mud collection device, the sample for the biological Viscous samples, the sample state is an aqueous solid, subject to quantitative dilution after grinding determination, resulting in this sampling method is limited in practice, and research Grinding, dilution of mud samples and then measured, but also increased the determination of the steps and the rate of contamination, making the detection of mucus-forming bacteria is difficult to daily.
The heterotrophic bacteria identified in this section are a class of planktonic bacteria living in seawater cooling water, and their presence and quantity can directly reflect the cold water But the degree of biological pollution system. This part of the abandoned mud collection device, direct collection of water samples to determine the number of heterotrophic bacteria, simplifying the sampling and preparation steps Sudden, so that the determination of heterotrophic bacteria can be daily, to improve the operation and management of water cooling water level.
1 Scope
This part of GB/T 33584 specifies the requirements for seawater cooling water quality and the determination of heterotrophic bacteria in seawater cooling water by plate counting Principle, reagents and materials, instruments and equipment, analysis and determination, colony count, the calculation of the total number of colonies and reporting methods.
This part is applicable to the determination of heterotrophic bacteria in seawater cooling water and also to the determination of heterotrophic bacteria in the original seawater.
2 Normative reference documents
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Heterotrophic bacteria
The use of organic molecules as energy microbes.
3.2 Colony forming unit; CFU
The number of colonies determined by plate counting.
3.3 Spread colony
In the agar medium surface was diffuse growth of colonies.
4 Water quality requirements
The main water quality indicators of seawater cooling water shall meet the requirements of Table 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 33584.6-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 33584.1-2017 — Seawater quality requirements and analysis method for seawater cooling system—Part 1:Determination of calcium and magnesium
GB/T 33584.2-2017 — Seawater quality requirements and analysis methods for seawater cooling system—Part 2: Determination of zinc
Secure payment via Stripe
Payments accepted
GB/T 33584.6-2017
$145.00