GB/T 33549-2017Small-size light piping water irrigation machines - Specification for performance evaluation (English PDF)

轻小型管道输水灌溉机组 性能评价规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 33549-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 9, 2017

Implementation date

October 1, 2017

Scope

GB/T 33549-2017 is the English-translated version of 轻小型管道输水灌溉机组 性能评价规范.

GB/T 33549-2017 is the Chinese standard "Small-size light piping water irrigation machines - Specification for performance evaluation". Its scope clause reads: This standard specifies the performance rating of small and medium-sized pipeline irrigation units, other requirements, test methods, inspection rules and sex Can level identification.

This standard applies to supporting power <= 11.03kW hand-lift, trolley and tractor drag light small pipe irrigation unit (Hereinafter referred to as pipe irrigation machine).

Its clauses include normative reference documents; performance rating evaluation index.

Found what you need?

Document preview — GB/T 33549-2017

National Standard of the People's Republic of China

ICS
65.060.35
Classification
B 91

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 normative reference documents
  • 3 performance rating evaluation index

1 Scope

This standard specifies the performance rating of small and medium-sized pipeline irrigation units, other requirements, test methods, inspection rules and sex

Can level identification.

This standard applies to supporting power <= 11.03kW hand-lift, trolley and tractor drag light small pipe irrigation unit (Hereinafter referred to as pipe irrigation machine).

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article

Pieces. For undated references, the latest edition (including all modifications) applies to this document.

GB/T 2828.1 Sampling inspection procedures Part 1. Batch inspection sampling plan for retrieval by quality limit (AQL)

GB/T 2829 Periodic inspection count Sampling procedures and tables (for inspection of process stability)

GB/T 3216 rotary power pump hydraulic performance acceptance test 1, 2 and 3

GB/T 25405 light and small pipeline irrigation unit

3 performance rating evaluation index

This standard through the assessment of pipe irrigation pump the provisions of the flow, the provisions of the head and pipe irrigation fuel consumption rate or tube irrigation efficiency to determine the pipe

Performance level. The performance grade of the pipe filling machine is divided into three grades. 1, 2, 3, and the performance is the highest. The evaluation of each grade of performance means

The values shall be in accordance with Table 1.

Table 1 performance grade

Specifies the flow gauge

Driven by a diesel engine

Fuel consumption rate of pipe irrigation machine

Electromechanical power of pipe - driving machine etaG

Motor power <= 3kW Motor power > 3kW

Level 1 QG (1 5%) HG (1 3%)

Value x 85%

etaG >= GB/T 25405

Value /0.955 0.09

etaG >= GB/T 25405

Value /0.955 0.10

Grade 2 QG (1 ± 5%) HG (1 ± 3%)

GB/T 25405 specified value ×

85% <= G GB/T 25405

Of the specified value /1.07

GB/T 25405 specified value /

0.955 <= eta G GB/T 25405

Of the specified value /0.955 0.09

GB/T 25405 specified value /

0.955 <= eta G GB/T 25405

Of the specified value /0.955 0.10

Grade 3 QG (1 ± 8%) HG (1 ± 5%)

GB/T 25405 specified value /

Of the specified value

GB/T 25405 specified value

Set value/0.955

GB/T 25405 specified value

Value /0.955

QG, HG are the flow rate of the pump in GB/T 25405, the stipulated value of the head and the difference. According to the provisions of GB/T 25405 to determine the motor as the driving force

Of the efficiency of the pipe machine, the motor efficiency and pump performance point efficiency are not tolerated. The head gauge of the pump is allowed to enter in accordance with the provisions of GB/T 25405

Line revision.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 33549-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included