GB/T 33252-2016Nanotechnology - Performance testing for laser confocal microscope Raman spectrometers (English PDF)
纳米技术 激光共聚焦显微拉曼光谱仪性能测试
Open the GB/T 33252-2016 preview as PDF
This is a limited preview
Buy now to download the full PDF (24 pages)
Issued by
General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Level / Type
National · Recommended
Issue date
December 13, 2016
Implementation date
July 1, 2017
Scope
GB/T 33252-2016 is the English-translated version of 纳米技术 激光共聚焦显微拉曼光谱仪性能测试.
China's national standard for testing the performance of laser confocal micro-Raman spectrometers. It specifies the terms and definitions, the instrument structure, the requirements, the test methods and the test report, with informative annexes on the composition of such an instrument, on the reference specimens used to calibrate it and on a reference format for the test report. It applies to dispersive confocal micro-Raman spectrometers using a continuous laser excitation source with single, double or triple stage spectrometers, and it does not apply to non-dispersive instruments such as Fourier transform Raman spectrometers or to instruments based on pulsed laser sources. Raman spectroscopy works because a small fraction of the light scattered by a material is scattered inelastically, shifted in frequency by the vibrational modes of the molecules or the lattice it met. That shift is a fingerprint of chemical bonding and of crystal structure, and combining it with a confocal microscope gives a spectrum from a volume about a micron across - which is what makes it the workhorse of nanomaterials characterisation. It is the standard way to distinguish graphene from graphite and to count layers, to identify carbon nanotubes and measure their diameter, to tell one polymorph from another and to measure strain in a semiconductor. The problem is that the measurement is comparative in practice: laboratories compare peak positions, widths and intensity ratios, and those depend on the instrument as much as the sample. So the instrument's spectral resolution, wavenumber accuracy, spatial resolution and sensitivity have to be established and stated, which is what this standard specifies. Issued on 13 December 2016 and in force since 1 July 2017.
Document preview — GB/T 33252-2016
National Standard of the People's Republic of China
- ICS
- 17.180.30
- Classification
- N 35
Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Contents
- 1 Scope
- 3 Test Report
- 5 Test Method
- 7 Appendix C (informative) Test Report Reference Format
- 9 Reference 11
Foreword
2 terms and definitions
Instrument structure 4 requirements 2
1 Scope
China's national standard for testing the performance of laser confocal micro-Raman spectrometers. It specifies the terms and definitions, the instrument structure, the requirements, the test methods and the test report, with informative annexes on the composition of such an instrument, on the reference specimens used to calibrate it and on a reference format for the test report. It applies to dispersive confocal micro-Raman spectrometers using a continuous laser excitation source with single, double or triple stage spectrometers, and it does not apply to non-dispersive instruments such as Fourier transform Raman spectrometers or to instruments based on pulsed laser sources. Raman spectroscopy works because a small fraction of the light scattered by a material is scattered inelastically, shifted in frequency by the vibrational modes of the molecules or the lattice it met. That shift is a fingerprint of chemical bonding and of crystal structure, and combining it with a confocal microscope gives a spectrum from a volume about a micron across - which is what makes it the workhorse of nanomaterials characterisation. It is the standard way to distinguish graphene from graphite and to count layers, to identify carbon nanotubes and measure their diameter, to tell one polymorph from another and to measure strain in a semiconductor. The problem is that the measurement is comparative in practice: laboratories compare peak positions, widths and intensity ratios, and those depend on the instrument as much as the sample. So the instrument's spectral resolution, wavenumber accuracy, spatial resolution and sensitivity have to be established and stated, which is what this standard specifies. Issued on 13 December 2016 and in force since 1 July 2017.
This standard specifies the terms and definitions of laser confocal microscopy Raman spectrometer, instrument structure, technical requirements, test methods and so on. This standard applies to continuous laser as the excitation light source, with single-stage, two or three spectrometer dispersion-type confocal microscopy Raman spectroscopy Instrument (hereinafter referred to as instrument). This standard does not apply to non-dispersive Raman spectroscopy such as Fourier transform Raman spectrometer and Raman light based on pulsed laser light source Spectrometer.
3 instrument structure
The laser emitted from the laser is subjected to an interference filter to the sample surface to excite the sample, the excitation light is irradiated by a Rayleigh filter and a confocal pinhole, Seam, raster, and finally reach the detector to detect the Raman signal. Instrument structure diagram shown in Figure 1. See Appendix A for details.
3 Test Report
3 Appendix A (informative) Composition of laser confocal microscopy Raman spectrometer
5 Appendix B (informative) Standard specimen for calibration of laser confocal microscopic Raman spectrometer
9 Reference 11
This standard is drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed by the Chinese Academy of Sciences. This standard is under the national standard of nanotechnology standardization technical committee (SAC/TC279). The drafting of this standard. China Institute of Metrology, Institute of Semiconductors, Chinese Academy of Sciences, Xiamen University, Guangzhou measurement test study House, Horiba (China) Trading Co., Ltd. The main drafters of this standard. Ren Lingling, Tan Pingheng, Ren Bin, Gao Xitian, Ding Xiang, Wang Haiyan, Pu Yumei. Nano - technology laser confocal microscopy Raman spectrometer Performance Testing
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
Normative references
JY/T 011
Cited by
- GB/T 44075-2024Nanotechnology - Determination of the uniformity of SERS solid substrate - Raman mapping analysis
- GB/T 44935-2024Nanotechnologies - Measurement of the number of layers of MoS2 flakes - Raman spectroscopy method
- GB/T 36063-2018Nanotechnologies - Raman shift standard curve for spectrometer calibration
Similar standards
GB/T 32387-2015|GB/T 30111-2013|GB/T 17341-2018|GB/T 43971-2024|JY/T 011-1996
How to Buy GB/T 33252-2016
- 1Add to cart. Click the "Buy GB/T 33252-2016" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 30111-2025 — General specification for star sensor
GB/T 32387-2015 — Color assessment booth
GB/T 47310-2026 — Determination of total silicon, aluminium, iron, potassium, sodium, calcium, magnesium, manganese, phosphorus, titanium and sulfur in soil - Monochromatic excitation energy dispersive X-ray fluorescence spectrometry
Secure payment via Stripe
Payments accepted
GB/T 33252-2016
$180.00