GB/T 36063-2018Nanotechnologies - Raman shift standard curve for spectrometer calibration (English PDF)
纳米技术 用于拉曼光谱校准的标准拉曼频移曲线
Open the GB/T 36063-2018 preview as PDF
This is a limited preview
Buy now to download the full PDF (24 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 15, 2018
Implementation date
October 1, 2018
Scope
GB/T 36063-2018 is the English-translated version of 纳米技术 用于拉曼光谱校准的标准拉曼频移曲线.
China's national standard for the Raman shift calibration curve used to calibrate a spectrometer. It supplies the reference against which an instrument's wavenumber axis is set. This is the piece of metrology on which every Raman measurement rests, and it is easy to underestimate. A Raman spectrum is read as a set of shifts from the excitation line, and the quantities of interest are often small differences: a shift of a few wavenumbers distinguishes one polymorph from another, indicates strain in a semiconductor, or counts the layers in graphene. An instrument whose wavenumber axis is off by that much gives a confident wrong answer. Calibration is therefore performed against materials whose peak positions are established to high accuracy and which are stable, available and easy to mount - and fixing that curve in a national standard is what allows a spectrum measured in one laboratory to be compared with one measured in another, which is the whole basis of a spectral library.
Document preview — GB/T 36063-2018
National Standard of the People's Republic of China
- ICS
- 17.180.30
- Classification
- N 35
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Overview
- 5 Calibration conditions
- 6 Raman frequency shift calibration
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was proposed by the Chinese Academy of Sciences. This standard is under the jurisdiction of the National Nanotechnology Standardization Technical Committee (SAC/TC279). This standard was drafted by: China Academy of Metrology, Qingdao Haishu Group Co., Ltd. The main drafters of this standard. Ren Lingling, Yao Yayi, Gao Huifang, Wang Xunlong.
Raman spectroscopy has become a major measurement in the field of nanotechnology with its unique information, rich information, simple sample preparation, and no damage to the sample. One of the characterization means. With the development of new materials such as fullerenes, graphene, and carbon nanotubes and high-tech industries such as MEMS and semiconductors, As the requirements for the characterization and measurement of microstructures and stress effects continue to increase, so does the accuracy of Raman frequency shift measurements. such as The Raman frequency shift is closely related to the structure of the material. Its minor changes, in addition to the qualitative nature of the material, can also reflect charge doping and deformation stress. Therefore, the calibration of the Raman shift has significant implications for the development of Raman spectroscopy. The development of this standard will provide methods for the calibration of Raman shifts using standard substances and the uncertainty introduced by the calibration process for Raman The comparable and reliable basis for the frequency shift measurement results promotes the use and development of Raman spectroscopy in nanotechnology and other fields. Nanotechnology for Raman Spectroscopy Calibration Standard Raman frequency shift curve
1 Scope
China's national standard for the Raman shift calibration curve used to calibrate a spectrometer. It supplies the reference against which an instrument's wavenumber axis is set. This is the piece of metrology on which every Raman measurement rests, and it is easy to underestimate. A Raman spectrum is read as a set of shifts from the excitation line, and the quantities of interest are often small differences: a shift of a few wavenumbers distinguishes one polymorph from another, indicates strain in a semiconductor, or counts the layers in graphene. An instrument whose wavenumber axis is off by that much gives a confident wrong answer. Calibration is therefore performed against materials whose peak positions are established to high accuracy and which are stable, available and easy to mount - and fixing that curve in a national standard is what allows a spectrum measured in one laboratory to be compared with one measured in another, which is the whole basis of a spectral library.
This standard specifies the terms and definitions of Raman shift calibration curves, calibration conditions, Raman shift calibration, and uncertainty assessment. This standard applies to Raman spectrometer (hereinafter referred to as the instrument) Raman frequency shift calibration.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 33252-2016 Nanotechnology Laser Confocal Microscopy Raman Spectrometer Performance Test
3 Terms and definitions
The terms and definitions defined in GB/T 33252-2016 apply to this document.
4 Overview
Raman spectroscopy is a molecular scattering spectrometer that produces modulated frequencies due to inelastic scattering when the material is exposed to monochromatic radiation energy. The spectrum. The Raman frequency shift is closely related to the structure of the material. Its minor changes, in addition to the qualitative nature of the material, can also reflect the charge doping and shape. The stress is changed, so the Raman shift needs to be calibrated. When Raman spectrometers are used, monocrystalline silicon is generally used for preliminary calibration to check the instrumentation. state. When performing measurements, linear calibration of multiple Raman shifts across the entire raster range is required. At this point, the calibration of the Raman shift needs to be established Curves, and find the linear correlation coefficient of the calibration curve. This standard provides comparable and reliable basis for Raman frequency shift measurement results and promotes Raman The use and development of spectroscopy in nanotechnology and other fields.
5 Calibration conditions
5.1 Laboratory conditions The ambient temperature is 20 °C ~ 25 °C, the use of temperature fluctuation range does not exceed ± 2 °C. Relative humidity <= 60%.
5.2 Instrument warm-up Turn on the laser before testing. Preheat and settling times follow the instructions for the instrument.
6 Raman frequency shift calibration
6.1 Selection of reference materials Select the certified reference material that covers the Raman shift range of the sample to be tested. To meet the above conditions, it is advisable to select a solid and liquid sample
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
How to Buy GB/T 36063-2018
- 1Add to cart. Click the "Buy GB/T 36063-2018" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 33252-2016 — Nanotechnology - Performance testing for laser confocal microscope Raman spectrometers
GB/T 47310-2026 — Determination of total silicon, aluminium, iron, potassium, sodium, calcium, magnesium, manganese, phosphorus, titanium and sulfur in soil - Monochromatic excitation energy dispersive X-ray fluorescence spectrometry
GB/T 47321-2026 — Specification for the warning data exchange of the national emergency early warning dissemination system
Secure payment via Stripe
Payments accepted
GB/T 36063-2018
$180.00