Valid

GB/T 33093-2016Determination of chromium(VI) content in textiles dyeing and finishing auxiliaries (English PDF)

纺织染整助剂产品中六价铬含量的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 33093-2016 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 13, 2016

Implementation date

May 1, 2017

Scope

GB/T 33093-2016 is the English-translated version of 纺织染整助剂产品中六价铬含量的测定.

GB/T 33093-2016 is the Chinese standard "Determination of chromium(VI) content in textiles dyeing and finishing auxiliaries". Its scope clause reads: This standard specifies the determination method of chromium (VI) in textile dyeing and finishing auxiliaries.

This standard is applicable to the determination of chromium (VI) in various textile dyeing and finishing auxiliaries. Its clauses include theory; reagents and materials; apparatus; determination procedures.

Found what you need?

Document preview — GB/T 33093-2016

National Standard of the People's Republic of China

ICS
71.100.01
Classification
G 70

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword i
  • 1 Scope
  • 2 Normative references
  • 3 Theory
  • 4 Reagents and materials
  • 5 Apparatus
  • 6 Determination procedures
  • 7 Quantitation limit, recovery rate and precision
  • 8 Test report
  • Annex A (Informative) Liquid chromatogram of chromium (VI)

1 Scope

This standard specifies the determination method of chromium (VI) in textile dyeing and finishing auxiliaries.

This standard is applicable to the determination of chromium (VI) in various textile dyeing and finishing auxiliaries.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 6682 Water for analytical laboratory use - Specification and test methods

GB/T 8170 Rules of rounding off for numerical values & expression and judgment of limiting values

3 Theory

Dissolve the chromium (VI) in the textile dyeing and finishing auxiliaries with buffer solution, filter the extraction liquid formed via color development reaction and determine it using a liquid chromatograph equipped with a ultraviolet detector or a diode array detector, then quantify it with the external standard method.

4 Reagents and materials

Unless otherwise specified, only analytically pure reagent and Grade 3 water (defined in GB/T 6682) shall be adopted.

4.1 Phosphoric acid solution

dilute 700 mL of phosphoric acid (H3PO4, rho=1.71 g/mL) to 1,000 mL with water.

4.2 Diphenylcarbazide solution

dissolve 10 g of 1, 5-diphenylcarbazide (C13H14N4O) in 100 mL of acetone and add 1 drop of glacial acetic acid.

Note: The solution shall be stored at 4°C in a brown bottle, with the validity period being two weeks.

4.3 Buffer solution

dissolve 22.8 g (to the nearest of 0.01 g) of potassium phosphate, dibasic (K2HPO4·3H2O) in 1,000 mL of water, adjust the pH to 8.0±0.1 with phosphoric acid (4.1), and deoxidize it with argon or nitrogen.

4.4 Potassium dichromate (K2Cr2O7), guaranteed reagent

dried to constant at (120±2)°C.

4.5 Chromium (VI) standard stock solution, 1,000 mg/L

weigh 2.829 g (to the nearest of 0.0001 g) of potassium dichromate (K2Cr2O7) (4.4), dissolve it with water, then transfer, wash and dilute it to the scale into a 1,000-mL volumetric flask.

4.6 Chromium (VI) standard working solution, 10 mg/L

pipette 1 mL of chromium (VI) standard stock solution into a 100-mL volumetric flask, and dilute to the mark with potassium phosphate dibasic buffer solution (4.3).

4.7 Nitrogen (or argon)

with a purity of >= 99.998% (volume fraction);

4.8

C18 column or glass or polypropylene specimen tube filled with suitable reversed phase material.

5 Apparatus

5.1 High performance liquid chromatograph

equipped with ultraviolet detector or diode array detector.

5.2 Balance

with a sensibility of 0.1 mg.

5.3 Ultrasonic cleaner

with an operating frequency of 40 kHz.

5.4

Gas-guide tube.

5.5

Flowmeter.

5.6 Conical flask with stopper

250 mL and 150 mL.

5.7 Filtering membrane

0.22 µm, inorganic phase.

6 Determination procedures

6.1 Preparation of specimen solution

Pipette 100 mL of the buffer solution (with the air removed) (4.3) into a 250-mL conical flask with stopper, insert the gas-guide tube (5.4) (which must not touch the liquid surface), and introduce the nitrogen into the conical flask (4.7) at the flow rate of (50±10)mL/min for 5min. Weigh 1 g (to the nearest of 0.0001 g) of sample into the conical flask, cover the ground-glass stopper, shake it well, and place it into the ultrasonic cleaner (5.3) to extract for 30 min.

Note 1: The ultrasonic cleaner is not heated and the extraction is carried out at room temperature.

The C18 column (4.8) should be washed with 5 mL of methanol first, then with 5 mL of Grade 3 water, and then rinsed with 10 mL of buffer solution (4.3). After extraction, the solution in the conical flask shall be filtered through the C18 column (4.8) into a 150-mL conical flask. Pipette 5 mL of the filtrate into a colorimetric tube, add 1 mL of phosphoric acid solution (4.1) and 1 mL of diphenylcarbazide solution (4.2), and dilute to 10 mL with buffer solution (4.3). Let it stand for (15±5) min at room temperature then filter it through a 0.22 µm filtering membrane for instrument analysis.

Note 2: If the sample concentration is too high, it is recommended to dilute it to the appropriate concentration before subjecting it to instrument analysis.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 33093-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 33093-2016