GB/T 32896-2016Communication protocols for power cabin of electric vehicle (English PDF)
电动汽车动力仓总成通信协议
This is a limited preview
Buy now to download the full PDF (24 pages)
Need quotation for your management?
Get a formal quotation for GB/T 32896-2016 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
August 29, 2016
Implementation date
March 1, 2017
Scope
GB/T 32896-2016 is the English-translated version of 电动汽车动力仓总成通信协议.
GB/T 32896-2016 is the Chinese standard "Communication protocols for power cabin of electric vehicle".
Its scope clause reads: This Standard specifies the definition of the communication physical layer, data link layer and application layer of power cabin of electric vehicles (hereinafter referred to as power cabin) basing on the control area network (CAN).
This Standard applies to the communication between the power cabin of electric vehicle with the battery at quick-change mode and vehicle equipment.
Its clauses include terms and definitions; general rules; physical layer; data link layer; application layer; message classification; message format and content; basic parameter 63489 00f801h 6 11; alarm 63490 00f802h 6 42 event power.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on AUGUST 29, 2016 and took effect on MARCH 1, 2017.
Found what you need?
Document preview — GB/T 32896-2016
National Standard of the People's Republic of China
- ICS
- 29.200
- Classification
- K 81
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions5
- 4 General rules7
- 5 Physical layer7
- 6 Data link layer7
- 7 Application layer8
- 8 Message classification9
- 9 Message format and content11
- Annex A (Informative) Fault diagnosis message of power cabin24
Foreword
This Standard was drafted according to the rules given in GB/T 1.1-2009.
1 Scope
This Standard specifies the definition of the communication physical layer, data link layer and application layer of power cabin of electric vehicles (hereinafter referred to as power cabin) basing on the control area network (CAN).
This Standard applies to the communication between the power cabin of electric vehicle with the battery at quick-change mode and vehicle equipment.
Event response Power cabin
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 19596-2004 Terminology of electric vehicles
ISO 11898-1:2003 Road vehicle - Control area network (CAN) - Part 1. Data link layer and physical signaling
ISO 11898-2:2003 Road vehicle - Control area network (CAN) - Part 2. High-speed medium access unit
ISO 11898-5:2006 Road vehicles - Controller area network (CAN) - Part 5. High-speed medium access unit with low-power mode
SAE J1939-11.2006 Recommended practice for serial control and communication vehicle network - Part 11. Physical layer, 250 Kbits/s, twisted shielded pair
SAE J1939-21.2006 Recommended practice for serial control and communication vehicle network - Part 21. Data link layer
SAE J1939-73.2006 Recommended practice for serial control and communication vehicle network - Part 73. Application Layer - Diagnostics module voltage Resolution. 0.01 V/bit, offset. 0 V, value range. 0 V ~ 24 V 11 2 bytes 10069 Extremely-large-deviation voltage value of single battery or battery module voltage Resolution. 0.01 V/bit, offset. 0 V, value range. 0 V ~ 24 V 13 1 byte 10070 Low value of discharging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 14 1 byte 10071 High value of discharging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 15 1 byte 10072 Large-deviation value of discharging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 16 1 byte 10073 Extremely low value of discharging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 17 1 byte 10074 Extremely high value of discharging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 18 1 byte 10075 Extremely-large-deviation value of discharging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 19 1 byte 10076 Low value of charging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 20 1 byte 10077 High value of charging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 21 1 byte 10078 Large-deviation value of charging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 22 1 byte 10079 Extremely low value of charging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 23 1 byte 10080 Extremely high value of charging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 24 1 byte 10081 Extremely-large-deviation value of charging temperature Resolution. 1 °C/bit, offset. -50 °C, value range. -50 °C ~ 200 °C 25 2 bytes 10082 SOC low threshold Resolution. 0.1 %/bit, offset. 0 %, value range. 0 % ~100 %
3 Terms and definitions
The following terms and definitions and those defined in GB/T 19596-2004 apply to this document.
3.1 Power cabin of EV
The device in electric vehicles, carrying and locking a number of fast-change battery boxes, electrically and mechanically connecting with quick-change battery boxes and vehicles, and for the management of quick-change battery box.
3.2 Frame
A series of data bits that form a complete message.
3.3 CAN data frame
The ordered bit fields necessary to form the CAN protocol for transmitting data, starting at start-of-frame (SOF) and ending at end-of-frame (EOF).
3.4 Messages
One or more "CAN data frames" with the same parameter group number.
3.5 Identifier
The identification part of the CAN arbitration field.
3.6 Extended frame
The CAN data frame defined in the CAN bus, using a 29-bit identifier.
3.7 Priority
7 Application layer
7.2 The parameter groups are numbered using PGN; each node identifies the contents of the data packet according to the PGN.
7.3 It uses "Request PGN" to actively acquire the parameter group of other nodes.
7.4 It uses cyclic transmission and event driving to transmit data.
7.5 If more than one PGN data needs to be sent to implement a function, multiple
PGNs of the definition must be received to determine whether the function is sent successfully.
7.6 When defining a new parameter group, place the parameters of the same function, the parameters of the same or similar refresh frequency and the parameters belonging to the same subsystem in the same parameter group as far as possible. At the same time, the new parameter group shall make full use of 8-byte data width, to place the relevant parameters in the same group as far as possible, also it shall consider the scalability, reserving some bytes or bits, in order to be modified in the future.
7.7 When modifying the parameter group has been defined in this Standard, the definition of the defined byte or bit shall not be modified; the newly added parameter shall be related to the parameters already in the parameter group; it shall not add unrelated parameters to the defined PGN in order to save the number of PGNs.
7.8 The definition of fault diagnosis shall follow the requirements of the CAN bus diagnostic system in 5.1 of SAE J1939-73.2006; the definition of the fault diagnosis message is given in Annex A.
7.9 The single-byte parameter setting of invalid information unit shall be 0xFF, the double-byte parameter setting shall be 0xFFFF, the four-byte parameter setting shall be 0xFFFFFFFF, the invalid or reserved bit shall be set to 1.
8 Message classification
8.1 Basic information message
The basic information is used to transfer the attribute information of the power cabin.
The classification of the basic information message is shown in Table 3.
9 Message format and content
9.2.2 Alarm condition PGN63505
The alarm condition consists of 3 levels of alarm, the alarm severity. level 5 alarm > level 3 alarm > level 1 alarm. Bytes 1, 2 is level 1 alarm information; byte 4 is level 3 alarm information, bytes 6, 7, 8 is level 5 alarm information. The format of alarm message is shown in Table 10. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 24 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 11898-1:2003 · ISO 11898-2:2003 · ISO 11898-5:2006 · SAE J1939-11.2006 · SAE J1939-21.2006 · SAE J1939-73.2006
Similar standards
How to Download GB/T 32896-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 19596-2004 — Terminology of electric vehicles
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 32896-2016
$125.00