Scope
GB/T 32507-2024 is the English-translated version of 电能质量 术语.
China's national terminology standard for power quality, and the current edition of GB/T 32507, replacing the 2016 edition. It defines the basic terms of the subject across nine groups - general terms, supply voltage, system frequency, three-phase unbalance, voltage fluctuation and flicker, harmonics, interharmonics and waveform distortion, temporary and transient overvoltage, voltage swell, voltage dip and short interruption, and DC distribution - together with the terms of measurement, monitoring and evaluation, of earthing and shielding, of mitigation technologies and methods, of electromagnetic compatibility, and a final group of others. It closes with an index. Power quality is a field in which almost every term is contested, because the same physical phenomenon is described differently by the network operator whose equipment produced it, the customer whose equipment suffered from it, and the manufacturer whose equipment is blamed for it. A dip and a sag are the same event; a surge means one thing to a utility engineer and another to someone selling a socket strip; a harmonic can be expressed as a group, a subgroup or an individual order and the three give different numbers from the same waveform. Since power quality is also a contractual matter - supply agreements specify it, equipment warranties depend on it, and disputes are settled by reference to it - the vocabulary has to be fixed before anything else can be. That is what this standard does, and the 2024 revision shows the field still moving: it renames the swell and dip clause to match the revised GB/T 30137, renames the measurement clause to include monitoring and evaluation, adds a whole group of terms for DC distribution, and revises more than thirty individual definitions. Issued on 31 December 2024 and in force since 1 April 2025.
Document preview — GB/T 32507-2024
National Standard of the People's Republic of China
- ICS
- 29.020
- Classification
- K 04
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Basic terms of power quality
- 3.1 General terms
- 3.2 Supply voltage
- 3.3 System frequency
- 3.3.4 Frequency
- 3.4 Three-phase unbalance
- 3.5 Voltage Fluctuation and Flicker
- 3.5.7 Flash
- 3.6 Harmonics, interharmonics and waveform distortion
- 3.6.20 Quasi-steady-state harmonic
- 3.6.25 Harmonic probability density
- 3.6.29 Total demand
- 3.7 Temporary overvoltage and transient overvoltage
- 3.8 Voltage swell, voltage sag and short-term interruption
- 3.9 DC power distribution
- 5 Grounding and Shielding
- 6 Governance technologies and methods
- 6.20 Passive filter
- 7 Electromagnetic compatibility
Foreword
This document is given in accordance with GB/T 1.1-2020 "Guidelines for standardization work Part
1.Structure and drafting rules for standardization documents" Rule drafting. This document replaces GB/T 32507-2016 "Power Quality Terminology". Compared with GB/T 32507-2016, the main technical changes are.
--- Changed the relevant content of Chapter 1 (see Chapter 1, Chapter 1 of the.2016 edition);
--- Changed the name of
3.8 to "voltage swell, voltage dip and short interruption" (see 3.8,
2.8 of the.2016 edition);
--- Changed the name of Chapter 4 to "Measurement, Monitoring and Evaluation Methods" (see Chapter 4, Chapter 3 of the.2016 edition);
--- Changed the terminology items.
3.1.1 Power quality,
3.1.2 Power supply quality,
3.1.3 Power quality,
3.1.6 Power quality assessment,
3.1.7 Power supply reliability,
3.1.8 Equipment rated voltage,
1 Scope
China's national terminology standard for power quality, and the current edition of GB/T 32507, replacing the 2016 edition. It defines the basic terms of the subject across nine groups - general terms, supply voltage, system frequency, three-phase unbalance, voltage fluctuation and flicker, harmonics, interharmonics and waveform distortion, temporary and transient overvoltage, voltage swell, voltage dip and short interruption, and DC distribution - together with the terms of measurement, monitoring and evaluation, of earthing and shielding, of mitigation technologies and methods, of electromagnetic compatibility, and a final group of others. It closes with an index. Power quality is a field in which almost every term is contested, because the same physical phenomenon is described differently by the network operator whose equipment produced it, the customer whose equipment suffered from it, and the manufacturer whose equipment is blamed for it. A dip and a sag are the same event; a surge means one thing to a utility engineer and another to someone selling a socket strip; a harmonic can be expressed as a group, a subgroup or an individual order and the three give different numbers from the same waveform. Since power quality is also a contractual matter - supply agreements specify it, equipment warranties depend on it, and disputes are settled by reference to it - the vocabulary has to be fixed before anything else can be. That is what this standard does, and the 2024 revision shows the field still moving: it renames the swell and dip clause to match the revised GB/T 30137, renames the measurement clause to include monitoring and evaluation, adds a whole group of terms for DC distribution, and revises more than thirty individual definitions. Issued on 31 December 2024 and in force since 1 April 2025.
This document defines terms and definitions related to the field of power quality. This document applies to relevant areas of power quality technology and management in the production, transmission, distribution, storage and use of electricity.
2 Normative references
This document has no normative references.
3.1 General terms
3.1.1 Power qualitypowerquality The electrical characteristics at a specified point in the power system are related to the various indicators of voltage, current, and frequency that affect the normal operation (or operation) of electrical equipment. The degree of deviation from the benchmark technical parameters.
Note. Benchmark technical parameters generally refer to the index values under ideal power supply conditions. These parameters may involve the compatibility between power sources, power grids and loads.
3.1.2 Power supply quality quality of power supply A general term for power supply voltage quality, power supply reliability, and power supply service quality.
Note. Refers to the main responsibility of the power supplier in the interaction and influence between the electricity user and the power supplier.
3.1.3 A general term for the interference level of user power load on the public power grid, power factor and non-technical factors. Note
1.Electricity quality refers specifically to the main responsibility of the electricity user in the interaction and influence between the electricity user and the power supplier. Note
2.The interference mainly includes harmonic current, interharmonic current, negative sequence current, zero sequence current, power fluctuation, etc. Note
3.Non-technical factors mainly include using electricity according to regulations and paying electricity bills on time.
3.1.4 Voltage qualityvoltagequality The degree to which various indicators of actual voltage deviate from the benchmark technical parameters.
3.1.5 Current quality currentquality The degree to which various indicators of actual current deviate from the benchmark technical parameters.
3.1.6 The process of evaluating various power quality indicators through modeling simulation and/or power quality monitoring.
3.1.7 The ability of a power supply system to continuously supply power to users.
3.3 System frequency
3.3.4 Frequency
3.4.2 Positive sequence component,
3.4.3 Negative sequence component,
3.4.4 Zero sequence component,
3.4.5 Unbalance,
3.5.1 Voltage RMS Value curve,
3.5.2 Voltage variation,
3.5.3 Voltage fluctuation,
3.5.4 Voltage variation characteristics,
3.5.5 Steady-state voltage variation,
3.5 Voltage Fluctuation and Flicker
3.5.7 Flash
3.5.8 Short-time flicker value,
3.5.9 Long-time flicker value,
3.6.1 Waveform distortion,
3.6.2 Waveform quality,
3.6.3 Fundamental frequency,
3.6.4 Fundamental component,
3.6.5 Harmonic source,
3.6.6 Harmonic component,
3.6.11 System harmonic impedance,
3.6.12 Impedance frequency characteristics,
3.6.16 Interharmonic frequency,
3.6.17 Notch/gap,
3.6.18 Characteristic harmonic,
3.6.19 Non-characteristic harmonic,
3.6 Harmonics, interharmonics and waveform distortion
3.6.20 Quasi-steady-state harmonic
3.6.22 Interharmonic component,
3.6.23 Harmonic content (voltage or current),
3.6.24 Harmonic content rate,
3.6.25 Harmonic probability density
3.6.26 Total harmonic distortion rate,
3.6.27 Partial weighted harmonic distortion rate,
3.6.28 Maximum demand load current,
3.6.29 Total demand
3.6.30 Harmonic resonance,
3.6.32 Background noise,
3.6.35 Telephone interference factor,
3.6.39 Interference factor Harmonic group frequency,
3.6.40 interharmonic center subgroup frequency,
3.7.1 system maximum voltage,
3.7.2 system minimum voltage,
3.7.3 overvoltage voltage,
3.7.4 temporary overvoltage,
3.7.5 transient overvoltage,
3.7.7 temporary withstand overvoltage,
3.7.10 short-time power frequency withstand voltage,
3.8.1 Voltage swell,
3.8.2 Voltage dip,
6 Governance technologies and methods
6.20 Passive filter
6.21 Single-tuned filter,
6.22 Double-tuned filter,
6.25 Static switch,
6.26 Transfer switch,
6.27 Static Stop switch/solid-state transfer switch,
6.29 uninterruptible power supply,
6.30 emergency backup power supply system,
7.1 electromagnetic environment,
7.2 electrical Magnetic disturbance,
7.3 Electromagnetic compatibility,
7.4 Electromagnetic compatibility level,
7.5 Electromagnetic planning level,
7.6 Electromagnetic disturbance level,
7.8 Electromagnetic sensitivity Sensitivity,
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 33 pages — is available in the English PDF.
Referenced standards
Similar standards
GB/T 30137-2024|GB/T 32882-2016|GB/T 35727-2017|GB/T 17626.30-2023|GB/T 2900.1-2008
Editions of GB/T 32507
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 32507-2016 | Power quality - Terminology | first issue | Superseded |
| GB/T 32507-2024 | Power quality - Terminology | first revision | Current |
This page sells the current edition, GB/T 32507-2024. Earlier editions are listed for reference only.
How to Buy GB/T 32507-2024
- 1Add to cart. Click the "Buy GB/T 32507-2024" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2900.1-2008 — Electrotechnical terminology - Fundamental terms
GB/T 2900.12-2008 — Electrotechnical terminology - surge arresters,low-voltage surge protective devices and components
GB/T 2900.16-2025 — Electrotechnical terminology - Power capacitors
Secure payment via Stripe
Payments accepted
GB/T 32507-2024
$810.00