GB/T 32212-2015Standard practice for testing fixed-wavelength photometric detectors used in liquid chromatography (English PDF)
液相色谱用固定波长光度检测器的测试方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 32212-2015 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 10, 2015
Implementation date
July 1, 2016
Scope
GB/T 32212-2015 is the English-translated version of 液相色谱用固定波长光度检测器的测试方法.
GB/T 32212-2015 is the Chinese standard "Standard practice for testing fixed-wavelength photometric detectors used in liquid chromatography".
Its scope clause reads: This standard is used to guide the optical performance of the detector test, the detector is a liquid chromatography system at 210nm ~ 800nm \u200b\u200bwavelength range Detecting means one or more fixed wavelengths work around inside.
Generally use test wavelength 254nm, you can also choose other wavelengths. This standard is intended to describe the performance of the detector, including independent of the chromatographic system static performance and dynamic performance under mobile phase conditions.
About LC program general description, see reference [1] to [9]. Rationale for HPLC detector, structure, use and evaluate information, see reference [10], [11] and [1] to [7] involved Detector content.
This standard does not involve security issues relating to the actual use of the process. Users are to determine the limitations of the standard applications, and Responsibility to develop appropriate safety and health practices. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 32212-2015
National Standard of the People's Republic of China
- ICS
- 17.180.99
- Classification
- N 52
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 3.1 Absorbance values calibration
- 3.2 Drift
- 3.3 Dynamic
- 3.4 The linear range linearrange
1 Scope
This standard is used to guide the optical performance of the detector test, the detector is a liquid chromatography system at 210nm ~ 800nm wavelength range
Detecting means one or more fixed wavelengths work around inside. Generally use test wavelength 254nm, you can also choose other wavelengths.
This standard is intended to describe the performance of the detector, including independent of the chromatographic system static performance and dynamic performance under mobile phase conditions.
About LC program general description, see reference [1] to [9].
Rationale for HPLC detector, structure, use and evaluate information, see reference [10], [11] and [1] to [7] involved
Detector content.
This standard does not involve security issues relating to the actual use of the process. Users are to determine the limitations of the standard applications, and
Responsibility to develop appropriate safety and health practices.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
ASTME275 ultraviolet, visible and near-infrared spectrophotometer performance description and test methods (Practicefordescribingand measuringperformanceofultraviolet, Visible, andnear-infraredspectrophotometers)
ASTME682 term liquid chromatography (Practiceforliquidchromatographytermsandrelationships)
3 Terms and Definitions
ASTME275, ASTME682 define the following terms and definitions apply to this document.
3.1 Absorbance values calibration
Corrected absorbance within the range of ± 5% of the verification process.
3.2 Drift
Measuring 1h, the average slope of the absorbance units per hour (AU/h) represents the noise envelope.
3.3 Dynamic
At a flow rate of 1.0mL/min under the condition.
3.4 The linear range linearrange
The linear range of photometric detector is the ratio of the mobile phase the test substance concentration and response at the detector constant within ± 5% of the
Corresponding to the concentration range, a detailed description is given in Figure 1. Linear concentration range should be based on the highest linearity and minimum detectable concentration or the minimum concentration of linear
The ratio of the greater.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 32212-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 32212-2015
$185.00