GB/T 32211-2015Standard practice for testing variable-wavelength photometric detectors used in liquid chromatography (English PDF)

液相色谱用可变波长光度检测器的测试方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32211-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 10, 2015

Implementation date

July 1, 2016

Scope

GB/T 32211-2015 is the English-translated version of 液相色谱用可变波长光度检测器的测试方法.

GB/T 32211-2015 is the Chinese standard "Standard practice for testing variable-wavelength photometric detectors used in liquid chromatography".

Its scope clause reads: This standard is used to guide the variable-wavelength photometric detector (VWPD) performance tests, the detector is in a liquid chromatography system 190nm ~ detecting means of one or more wavelengths within the working range of the wavelength of 800nm.

Of the GB/T 32212-2015 consistent, generally Use test wavelength 254nm, you can also choose other wavelengths for testing. This standard is intended to describe the performance of the detector, including independent of the chromatographic system static performance and dynamic performance of the mobile phase through.

About LC program general description, see reference [1] to [9]. Rationale for HPLC detector, structure, use and evaluate information, see reference [10], [11] and [1] to [7] involved Detector content.

This standard does not involve security issues relating to the actual use of the process. Users are to determine the limitations of the standard applications, and Responsibility to develop appropriate safety and health practices. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 32211-2015

National Standard of the People's Republic of China

ICS
17.180.99
Classification
N 52

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 3.1 Absorbance calibration
  • 3.2 Drift
  • 3.3 Dynamic
  • 3.4 The linear range linearrange

1 Scope

This standard is used to guide the variable-wavelength photometric detector (VWPD) performance tests, the detector is in a liquid chromatography system

190nm ~ detecting means of one or more wavelengths within the working range of the wavelength of 800nm. Of the GB/T 32212-2015 consistent, generally

Use test wavelength 254nm, you can also choose other wavelengths for testing.

This standard is intended to describe the performance of the detector, including independent of the chromatographic system static performance and dynamic performance of the mobile phase through.

About LC program general description, see reference [1] to [9].

Rationale for HPLC detector, structure, use and evaluate information, see reference [10], [11] and [1] to [7] involved

Detector content.

This standard does not involve security issues relating to the actual use of the process. Users are to determine the limitations of the standard applications, and

Responsibility to develop appropriate safety and health practices.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

ASTME275 ultraviolet, visible and near infrared spectrophotometer performance characterization and test methods (Practicefordescribingand measuringperformanceofultraviolet, Visible, andnear-infraredspectrophotometers)

ASTME682 term liquid chromatography (Practiceforliquidchromatographytermsandrelationships)

3 Terms and Definitions

ASTME682, and the following terms and definitions apply ASTME275 defined in this document.

3.1 Absorbance calibration

Corrected absorbance within the range of ± 5% of the verification process.

3.2 Drift

Measuring 1h, the average slope of the absorbance units per hour (AU/h) represents the noise envelope.

3.3 Dynamic

At a flow rate of 1.0mL/min under the condition.

3.4 The linear range linearrange

Variable wavelength photometric detector linear range of the mobile phase is to test the detector response versus concentration ratio constant in substance

Concentration within the range of ± 5% corresponding to FIG. 1 and 7.2.2 have been described in detail. The linear range is the highest linear concentration and minimum detectable concentration

Degrees or larger minimum linear concentration ratio.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 32211-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32211-2015

$205.00