Valid

GB/T 32206-2015Standard practice for testing electrolytic conductivity detectors used in gas chromatography (English PDF)

气相色谱用电导检测器测试方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 32206-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 10, 2015

Implementation date

July 1, 2016

Scope

GB/T 32206-2015 is the English-translated version of 气相色谱用电导检测器测试方法.

GB/T 32206-2015 is the Chinese standard "Standard practice for testing electrolytic conductivity detectors used in gas chromatography". Its scope clause reads: This standard specifies the electrical conductivity detector gas chromatography performance test method.

This standard applies to gas chromatography with conductivity detector for detecting sample (ELCD). Its clauses include general description.

Found what you need?

Document preview — GB/T 32206-2015

National Standard of the People's Republic of China

ICS
17.180.99
Classification
N 52

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 General Description
  • 4.1 Conductivity detector shown in Figure 1, comprising

1 Scope

This standard specifies the electrical conductivity detector gas chromatography performance test method.

This standard applies to gas chromatography with conductivity detector for detecting sample (ELCD).

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

ASTME260 packed column gas chromatography Practices (Practiceforpackedcolumngaschromatography)

ASTME355 GC terms and norms of mutual relations (Practiceforgaschromatographytermsand relationships)

3 General Description

3.1

standard applied directly to the conductivity detector for detecting nickel as the catalyst for the oxidation or reduction reaction samples. If needed,

Deionized solvent by dissolving away the reactants to achieve the purpose of interference cancellation, conductivity cell for measuring the ionic conductivity of the reaction product.

3.2

standard describes the operation and performance conductivity detector, excluding the column. However, when the detector and chromatography columns and other portions

When the member is connected, it can also be used to evaluate the performance of the entire system.

3.3

Unless the conductivity detector is recommended methods have special requirements, conventional gas chromatography procedures should be in accordance with Regulation ASTME260 set. Definitions and terminology associated gas chromatograph in accordance with the provisions of ASTME355.

3.4

Although it is possible to observe and measure the conductivity detector in a single or different conditions of each of the properties, in particular selective different modes,

However, this standard requires a complete detector characteristics should be obtained under the same experimental conditions, including the flow geometry, gases and solvents to

And temperature. It should be noted that to fully explain the performance of the detector, which needs to be measured over a range of conditions within the detector range performance. The performance of the standard described in enough common, so can be used under any conditions.

Linear and response speed 3.5 data processing system should not be distorted or interfere with performance of the detector. If the output device and the terminal detector

Between the use of additional amplifiers, should first determine the characteristics of the amplifier.

3.6

standard does not involve security issues relating to the actual use of the process. Users are to determine the limitations of the standard applications, and

We have the responsibility to develop appropriate safety and health practices.

Principle 4 conductivity detector

4.1 Conductivity detector shown in Figure 1, comprising

a control module, a reactor assembly and testing pools.

The control module integrates all the electronic components to perform monitoring, can monitor traffic, reaction temperature and the flow cell. Functionally independent from the gas phase

Chromatography, in some cases, to design functional components by gas chromatography. GC different modes require different reactor design and the analyzer

Measurement cell assembly, therefore, should choose a suitable reactor and configure the detection cell GC.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 32206-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 32206-2015

$185.00