GB/T 32086-2015Requirement of vertical flammability characteristic and test method for certain category automobile interior material (English PDF)
特定种类汽车内饰材料垂直燃烧特性技术要求和试验方法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 32086-2015 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 9, 2015
Implementation date
July 1, 2016
Scope
GB/T 32086-2015 is the English-translated version of 特定种类汽车内饰材料垂直燃烧特性技术要求和试验方法.
GB/T 32086-2015 is the Chinese standard "Requirement of vertical flammability characteristic and test method for certain category automobile interior material".
Its scope clause reads: This Standard specifies the technical requirements of vertical flammability characteristic and test methods for certain category automobile interior material.
This Standard is applicable to interior curtains, sun shades and/or other interior materials for M3 vehicles that are used to carry more than 22 passengers; it is not applicable to city buses that have standing passengers.
Its clauses include terms and definitions; technical requirements; test methods.
Found what you need?
Document preview — GB/T 32086-2015
National Standard of the People's Republic of China
- ICS
- 43.040.40
- Classification
- T 24
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Terms and definitions4
- 3 Technical requirements4
- 4 Test methods4
- Annex A11
1 Scope
This Standard specifies the technical requirements of vertical flammability characteristic and test methods for certain category automobile interior material.
This Standard is applicable to interior curtains, sun shades and/or other interior materials for M3 vehicles that are used to carry more than 22 passengers; it is not applicable to city buses that have standing passengers.
2 Terms and definitions
The following terms and definitions apply to this document.
2.1 burning rate
The ratio between combustion distance and time used, in millimeters per minute (mm/min).
3 Technical requirements
Vertical burning rate shall not exceed 100 mm/min.
4 Test methods
4.1 Principle
Vertically fix the specimen on the rectangular frame. Use the predetermined flame to ignite specimen in the combustion chamber. Determine the combustion distance and time used of the specimen.
4.2 Test equipment and appliances
4.2.1 Specimen holder
The specimen holder shall be a rectangular frame, as shown in Figure 1.The frame height is 560 mm.
4.2.2 Pressboard
Use U pressboard to ensure the vertical flatness of specimen on the specimen holder. The U pressboard shall be flat with rigidity. It is made of suitable material.
The size equals to the specimen holder size. The thickness is 1.0 mm ± 0.1 mm.
Drill 12 round holes of which the diameter is about 4 mm on both sides of the pressboard.
4.2.3 Gas light
Gas light provides test fire source. Its description and structure shall comply with the provisions of Annex A.
4.2.4 Gas
The gas used by gas light is industrial propane gas, butane gas or liquefied petroleum gas.
4.2.5 Marker line
White mercerized cotton thread of which the maximum linear density is 50 tex.
4.2.6 Stopwatch
The stopwatch accuracy to measure time shall not be less than 0.5 s.
4.2.7 Steel ruler
The steel ruler scale is more than 600 mm. The accuracy is 1 mm.
unit. mm
4.2.8 Fuming hood
The specimen holder shall be placed in the fuming hood. The internal volume of fuming hood is 20 ~ 110 times specimen holder volume. Any one among the fuming hood's length, width and height must not exceed 2 times any size of the other two sizes.
4.3 Specimen
4.3.1 Size
The size of specimen. length is 560 mm ± 2 mm; width is 170 mm ± 2 mm; the thickness is component thickness.
4.3.3 Pre-treatment
Place the specimen under standard state of which the temperature is 23°C±2°C, the relative humidity is 50%±5% for at least 24 h, till the test starts.
4.4 Test procedure
4.4.1
Carry out the test under the environmental conditions of which the temperature is 10°C~30°C, the relative humidity is 15% ~ 80%.
4.4.3
Fix the pretreated specimen on the fixing-needle of specimen holder, close to the location column. Then press the U-pressboard on it to ensure that the fixing-needle goes through each round hole on the pressboard. The specimen shall be at least 20 mm away from the frame. Mount the specimen holder on the top bracket of combustion chamber to ensure the specimen vertical.
4.4.8
Measure the following times, in seconds (s).
4.5 Calculation
For the specimen burnt to at least the first marker line, the burning speed (vi) shall be calculated according to the following equation.
4.6 Representation of burning speed result
4.6.1
If the specimen cannot keep burning for 5s after ignition for 15 s in the flame, or the flame burns out by itself before reaching to the first marker line, then the burning speed shall be regarded as it fails to comply with requirements.
Both shall be represented as 0 mm/min.
GB/T 31970-2025 | GB/T 32692-2016 | GB 38185-2026 | […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 32086-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 32086-2015
$145.00