Scope

GB/T 31975-2015 is the English-translated version of 呼吸防护用压缩空气技术要求.

GB/T 31975-2015 — This Standard specifies the quality indicators and test methods of compressed air for respiratory protection. This Standard is applicable to self-contained open-circuit compressed air breathing apparatus and compressed air line breathing apparatus for occupational protection and escape.

This Standard is not applicable to compressed air for medical use, breathing equipment for diving and compressed air for aviation breathing equipment

Found what you need?

Document preview — GB/T 31975-2015

National Standard of the People's Republic of China

ICS
13.340.30
Classification
C 73

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative References...4
  • 3 Terms and Definitions...4
  • 4 Technical Requirements...5
  • 5 Test Methods...5
  • 6 Collecting Requirements for Gaseous Samples...6

Foreword

This Standard was drafted as per the rules specified in GB/T 1.1-2009.

This Standard was proposed by State Administration of Work Safety.

This Standard shall be under the jurisdiction of National Technical Committee for

Standardization of Personal Protection (SAC/TC 112).

Drafting organizations of this Standard: China Academy of Safety Science and

Technology; Research Institute of Chemical Defense, General Armaments Department;

Quartermaster Equipment Research Institute of the General Logistic Department; MSA

(China) Safety Equipment Co., Ltd.; and Draeger Safety Equipment (China) Co., Ltd.

Chief drafting staffs of this Standard: Zhang Mingming, Ding Songtao, Fu Yahui, Dong

Huijun, Yao Haifeng, Chang Hong, Yang Xiaobing, Zhang Huijun, and Zhu Hua.

Technical Requirements of Compressed Air for

Respiratory Protection

1 Scope

This Standard specifies the quality indicators and test methods of compressed air for

respiratory protection.

This Standard is applicable to self-contained open-circuit compressed air breathing

apparatus and compressed air line breathing apparatus for occupational protection

and escape.

This Standard is not applicable to compressed air for medical use, breathing

equipment for diving and compressed air for aviation breathing equipment

2 Normative References

The following documents are essential to the application of this document. For the

dated documents, only the versions with the dates indicated are applicable to this

document; for the undated documents, only the latest version (including all the

amendments) are applicable to this document.

GB/T 3863-2008 Industrial Oxygen

GB/T 5832.2 Determination of Moisture in Gases - Part 2: Dew Point Method

GB/T 8984 Determination of Carbon Monoxide Carbon Dioxide and Hydrocarbon

in Gases - Gas Chromatographic Method

GB/T 18204.2-2014 Examination Methods for Public Places - Part 2: Chemical

Pollutants

3 Terms and Definitions

For the purpose of this document, the following terms and definitions apply.

3.1 Dew point

At constant pressure, the temperature at which the moisture in the gas reaches

saturation and condenses into dew or frost (ice).

3.2 Dew point method

A method of measuring the dew point of the gas to reflect the moisture content of

compressed air.

3.3 Atmospheric dew point

Dew point of compressed air measured at atmospheric pressure.

4 Technical Requirements

The quality of compressed air for respiratory protection shall meet the requirements of

various indicators in Table 1.

Table 1 -- Quality Indicators of Compressed Air for Respiratory Protection

Table 1 – Continued

5 Test Methods

5.1 Determination of oxygen

5.1.1 The determination of the oxygen content in compressed air should adopt the

copper ammonia solution absorption method, and implement according to the

provisions of 4.2 in GB/T 3863-2008;

5.1.2 The oxygen content in the compressed air may also be measured by

paramagnetic analyzers, electrochemical analyzers and other instrumental analysis

methods. The accuracy of the instrument is at least ±0.2% oxygen (absolute value).

5.2 Determination of carbon monoxide

Quality indicators Indicator requirements a

Oxygen

Carbon monoxide

Carbon dioxide

19.5% (volume fraction) ~ 23.5% (volume fraction)

Quality indicators Indicator requirements a

Dew point

Oil mist and particulate matter

Peculiar smell No obvious peculiar smell

a The requirements for each indicator is the value under the standard state (20°C, 101.3 kPa).

5.2.1 The determination of carbon monoxide content may adopt the catalytic

methanation gas chromatography, and implement in accordance with the provisions of

GB/T 8984;

5.2.2 The determination of carbon monoxide content may also use non-spectroscopy

infrared gas analysis method, and implement according to 3.1 in GB/T 18204.2-2014.

5.3 Determination of carbon dioxide

5.3.1 The determination of carbon dioxide content may adopt the catalytic methanation

gas chromatography, and implement in accordance with the provisions of GB/T 8984;

5.3.2 The determination of carbon dioxide content may also use non-spectroscopy

infrared gas analysis method, and implement according to 4.1 in GB/T 18204.2-2014.

5.4 Determination of oil mist and particulate matter

The sample collection and determination of oil mist and particulate matter content shall

filter adopt the filter weighing method, and implement in accordance with the method

specified in Appendix A.

5.5 Determination of dew point

The determination of the dew point is performed in accordance with the provisions of

GB/T 5832.2.

6 Collecting Requirements for Gaseous Samples

When on-site testing is not convenient, gaseous samples shall be collected in

accordance with the following requirements:

a) The collected gaseous samples shall be representative of the compressed air

supplied by normal production;

b) Sample containers shall be filled at the same time and in the same filling position

in the same way;

c) The gas shall be collected from the same gas supply container into the sample

container through an appropriate connection; and the regulator shall not be

connected between the gas supply container and the sample container (allowing

the use of a control valve);

d) The sample container shall be directly connected to the analysis equipment after

appropriate pressure adjustments. At the same time, the analysis equipment

shall not be subjected to excessive pressure.

Appendix A

(Normative)

Test Methods of Oil Mist and Particulate Matter in the Compressed

Air

A.1 Principle

The oil mist and particulate matter in the gas sample shall be collected with a filter

membrane of known quality. The content of the oil mist and particulate matter in the

compressed air shall be calculated from the weight gain of the filter membrane and the

volume of the collected gas after sampling.

A.2 Instruments and materials

The instruments and materials required for the method include:

a) Filter membrane: perchloroethylene microporous filter membrane or other dust

measurement filter membrane, diameter 37mm or 40mm, and pore diameter no

greater than 1µm;

b) Sampling clip or sampling box: the size is consistent with the filter membrane,

which is used to hold the microporous filter membrane;

c) gas needle valve and rubber-plastic tube for connection;

d) flow meter with accuracy of 2%;

e) Analytical balance: accurate to 0.1 mg.

A.3 Preparation before sampling

The following preparations shall be made before sampling:

a) Wash and dry the sampling clamp and sampling box;

b) Dewater the filter membrane in a desiccator for at least 4h; weigh the mass, m1,

(accurate to 0.1mg); and put it into the numbered filter box. The weighed filter

membrane shall not be contaminated or adsorb oil or dust;

c) Connect the needle valve, sampling clamp and rotor flowmeter with plastic pipes

in order.

A.4 Sample collection

A.4.1 Adjust the outlet pressure of the compressed air cylinder or air supply equipment

to 0.1MPa ~ 0.12MPa (absolute pressure); and then connect the inlet of the needle

valve to the outlet of the compressed air equipment. With the needle valve closed,

insert the filter box into the filter box holder. Open the needle valve and adjust the flow

meter to allow the gas to pass through the filter membrane at a flow rate, V, of 10L/min

~ 20L/min to stabilize the gas flow and record the start time of sampling.

A.4.2 When the cumulative flow rate exceeds 1m3, close the needle valve and record

the end time of sampling. Take out the filter membrane, fold the dust-receiving side of

the filter membrane inward twice and place it in a clean container for transportation

and storage. During the transportation and storage process, prevent the dust falling off

or pollution.

A.4.3 When sampling from a pressure vessel, the pressure vessel shall be placed

upside down (valve facing down) for 5min before sampling. Gas cylinders and

components shall be kept above 0°C.

A.4.4 When sampling the compressor system, the compressed gas outlet or the filter

drying pipe connected to it shall keep hanging. When measuring the oil content, the

sample air shall be passed through a sufficient filter membrane medium; and then the

weight gain of the filter membrane shall be measured, or the decolorization of the filter

membrane shall be observed.

A.5 Sample weighing and result processing

A.5.1 Before weighing, place the sampled filter membrane in a desiccator to dewater

for more than 4 hours. After removing static electricity, weigh accurately on the

analytical balance and record the mass, m2, of the filter membrane and dust. The

difference between the relative humidity of the balance chamber before and after the

sampling of the membrane filter is no more than 10%.

A.5.2 The content of oil mist and particulate matter in the gas is calculated according

to Formula (A.1):

Where:

x - oil mist and particulate matter content, in mg/m3;

m2 - the mass of the filter membrane after sampling, in mg;

m1 --- the mass of the filter membrane before sampling, in mg;

V - sampling volume (converted to under standard state of 20°C and 101.3kPa), in m3.

A.5.3 The number of parallel samples collected at the same sampling point shall be no

less than 2. The same batch of samples shall contain at least one blank sample. The

test results of each sample shall be deducted from the blank value. The final result is

the average value of each parallel sample.

Bibliography

__________ END __________

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 31975-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
6 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 31975-2015

$95.00