Valid

GB/T 31850-2015Test method for thermogravimetry(TG) of no-matallic sealing materials (English PDF)

非金属密封材料热分解温度测定方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 31850-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 3, 2015

Implementation date

June 1, 2016

Scope

GB/T 31850-2015 is the English-translated version of 非金属密封材料热分解温度测定方法.

GB/T 31850-2015 is the Chinese standard "Test method for thermogravimetry(TG) of no-matallic sealing materials".

Its scope clause reads: This standard specifies the non-metallic sealing material thermal decomposition temperature measurement terminology and definitions, the principles outlined, test equipment, sample preparation, equipment Calibration, test procedures, test report and results presentation.

This standard applies to the determination of the decomposition temperature and decomposition rate of non-metallic sealing material is also suitable for the determination of non-metallic sealing materials contained Volatile matter content, additives and/or filler material, non-metallic sealing materials may also refer to the use of raw materials.

This standard applies to the dynamic mode (under the conditions of the program quality over time or temperature change) or isothermal mode (at a constant temperature with the quality Thermal weight measurement time) under. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 31850-2015

National Standard of the People's Republic of China

ICS
59.100.99
Classification
Q 69

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Terms and definitions
  • 2.1 Thermal gravimetric analysis thermogravimetry; TG
  • 2.2 Dynamic mass change measurement
  • 2.3 Isothermal mass change measurement
  • 2.4 TG curve
  • 2.5 Differential scanning calorimetry differentialscanningcalorimetry; DSC
  • 2.6 Differential thermal analysis differentialthermalanalysis; DTA
  • 2.7 Curie temperature
  • 2.8 Thermal decomposition temperature

1 Scope

This standard specifies the non-metallic sealing material thermal decomposition temperature measurement terminology and definitions, the principles outlined, test equipment, sample preparation, equipment

Calibration, test procedures, test report and results presentation.

This standard applies to the determination of the decomposition temperature and decomposition rate of non-metallic sealing material is also suitable for the determination of non-metallic sealing materials contained

Volatile matter content, additives and/or filler material, non-metallic sealing materials may also refer to the use of raw materials.

This standard applies to the dynamic mode (under the conditions of the program quality over time or temperature change) or isothermal mode (at a constant temperature with the quality

Thermal weight measurement time) under.

2 Terms and definitions

The following terms and definitions apply to this document.

2.1 Thermal gravimetric analysis thermogravimetry; TG

Under the program temperature control, a method of sample quality relationship with temperature or time measurements.

2.2 Dynamic mass change measurement

Under the program ramp rate, recording a technology sample mass with temperature change.

2.3 Isothermal mass change measurement

Under constant conditions, the quality of the sample recorded a technology change over time.

2.4 TG curve

Obtained by a thermal gravimetric analysis curve, the quality of the sample to the ordinate (y-axis) at a temperature of T or time t as the abscissa (x-axis).

2.5 Differential scanning calorimetry differentialscanningcalorimetry; DSC

Under the program temperature and a certain atmosphere, measuring the sample and reference was lost to the rate of heat flow and heating power (difference) and the temperature and/or time

Technical relations.

2.6 Differential thermal analysis differentialthermalanalysis; DTA

In the program temperature control, the temperature difference between the measuring technique the relationship between temperature and/or time of sample and reference material between.

2.7 Curie temperature

Magnetic material can be between the ferromagnetic transition temperature of the magnet rolls.

2.8 Thermal decomposition temperature

Thermal decomposition of material failure when the corresponding temperature.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 31850-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 31850-2015

$70.00