GB/T 31840.3-2025Aluminium alloy power cables with extruded insulation for rated voltages from 1 kV up to 35 kV - Part 3: Cables for rated voltage 35 kV (English PDF)
额定电压1kV(Um=1.2kV)到35kV(Um=40.5kV)铝合金芯挤包绝缘电力电缆 第3部分:额定电压35kV(Um=40kV)电缆
Open the GB/T 31840.3-2025 preview as PDF
This is a limited preview
Buy now to download the full PDF (43 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 5, 2025
Implementation date
February 1, 2026
Scope
GB/T 31840.3-2025 is the English-translated version of 额定电压1kV(Um=1.2kV)到35kV(Um=40.5kV)铝合金芯挤包绝缘电力电缆 第3部分:额定电压35kV(Um=40kV)电缆.
GB/T 31840.3-2025 is the Chinese national standard covering the 35 kV aluminium alloy cable - the conductor alloy and its creep behaviour at a termination, the insulation thickness and the screening, the electrical type tests, and the bending and connection requirements that differ from copper. At 24,500 words. Part 3 of the series. It replaces GB/T 31840.3-2015, under the China Electricity Council. In force from 1 February 2026. Issued on 5 October 2025, it has been in force since 1 February 2026, replacing GB/T 31840.3-2015.
Document preview — GB/T 31840.3-2025
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
- Replacing
- GB/T 31840.3-2015
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Rated voltage 35kV (Um=40.5kV) cable
- 4 Voltage markings and materials
- 9 The cable core, inner lining, and filler of a three-core cable. 10 metal layers
- 10 Spark Test for Extruded Sheaths
- 11 General Test Methods Methods
- 12 General Test Methods Method
- 13 Inspection Rule
- 14 General Test Methods Method
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part
1.Structure and Drafting Rules of Standardization Documents". Drafting. This document is GB/T 31840 "Aluminum Alloy Core Extruded Insulation with Rated Voltage of 1kV (Um=1.2kV) to 35kV (Um=40.5kV)". Part 3 of GB/T 31840, "Power Cables," has been published, including the following parts.
1.Cables with rated voltages of 1kV (Um=1.2kV) and 3kV (Um=3.6kV);
2.Cables with rated voltages from 6kV (Um=7.2kV) to 30kV (Um=36kV);
3.Cables with a rated voltage of 35kV (Um=40.5kV). This document replaces GB/T 31840.3-2015 "Aluminum Alloys with Rated Voltages from 1kV (Um=1.2kV) to 35kV (Um=40.5kV)". "Core-Extruded Insulated Power Cables Part
3.Cables with Rated Voltage of 35kV (Um=40.5kV)" is consistent with GB/T 31840.3-2015. Compared to previous versions, aside from structural adjustments and editorial changes, the main technical changes are as follows:
---Thermoplastic polypropylene insulation material has been added (see 4.2);
---Added halogen-free flame-retardant sheath material ST8 (see 4.3);
---Product naming has been added (see Chapter 5);
---The requirement for conductor structure type has been removed (see
5.2 in the.2015 edition);
---The technical requirements for the overlap ratio of metal shielding tape have been revised (see 10.2.2.2,.2015 version of 10.2.2);
---The technical requirements for the thickness of non-metallic sheaths have been revised (see 11.3,
13.3 in the.2015 edition);
1 Scope
GB/T 31840.3-2025 is the Chinese national standard covering the 35 kV aluminium alloy cable - the conductor alloy and its creep behaviour at a termination, the insulation thickness and the screening, the electrical type tests, and the bending and connection requirements that differ from copper. At 24,500 words. Part 3 of the series. It replaces GB/T 31840.3-2015, under the China Electricity Council. In force from 1 February 2026. Issued on 5 October 2025, it has been in force since 1 February 2026, replacing GB/T 31840.3-2015.
This document specifies the voltage markings and materials for 35kV (Um=40.5kV) aluminum alloy core extruded insulated power cables. Product naming, conductor, insulation, shielding, cable core, inner lining and filler, metal layer, outer sheath, inspection rules, markings, labels and accompanying documents, packaging The requirements for loading, transportation, and storage are described, along with the corresponding test methods. This document applies to aluminum alloy core extruded insulated power cables with a rated voltage of 35kV (Um=40.5kV) for fixed installation. This document does not apply to cables under special installation and operating conditions, such as overhead cables, mining industry cables, and nuclear power plants (within containment and surrounding areas). (Near) and underwater or ship cables.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included. For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document.
GB/T 2951.11-2008 General Test Methods for Insulation and Sheath Materials of Cables and Optical Fibers - Part
11 General Test Methods Methods
--- Thickness and Dimensional Measurement
--- Mechanical Property Testing
GB/T 2951.12-2008 General Test Methods for Insulation and Sheath Materials of Cables and Optical Fibers - Part
12 General Test Methods Method
---Thermal Aging Test
GB/T 2951.13-2008 General Test Methods for Insulation and Sheath Materials of Cables and Optical Fibers - Part
13.General Test Methods Methods for determining density. water absorption test, shrinkage test.
GB/T 2951.14-2008 General Test Methods for Insulation and Sheath Materials of Cables and Optical Fibers - Part
14 General Test Methods Method
---Low Temperature Test
GB/T 2951.21-2008 General Test Methods for Insulation and Sheath Materials of Cables and Optical Fibers - Part
21.Elastomer Compounds Test methods. ozone resistance test, heat stretching test, mineral oil immersion test.
GB/T 2951.31-2008 General Test Methods for Insulation and Sheath Materials of Cables and Optical Fibers - Part
31.Polyvinyl Chloride Blends Specialized test methods
---High temperature pressure test
---Crack resistance test
GB/T 2951.32-2008 General Test Methods for Insulation and Sheath Materials of Cables and Optical Fibers - Part
32.Polyvinyl Chloride Blends Specialized test methods
--- weight loss test
--- thermal stability test
GB/T 2951.41-2008 General Test Methods for Insulation and Sheath Materials of Cables and Optical Fibers - Part
41.Polyethylene and Polypropylene Special test methods for mixtures. environmental stress cracking test, melt index measurement method, direct combustion method for measuring carbon black and... (or) Thermogravimetric analysis (TGA) to measure carbon black content; microscopic assessment of carbon black dispersion in polyethylene.
GB/T 3048.4 Electrical Performance Test Methods for Wires and Cables - Part 4: DC Resistance Test of Conductors
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 43 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 3048.4Test methods for electrical properties of electric cables and wires — Part 4: Test of DC resistance of conductors
- GB/T 3048.10Test methods for electrical properties of electric cables and wires - Part 10: Spark test of extruded protective sheaths
GB/T 2951.11-2008 · GB/T 2951.12-2008 · GB/T 2951.13-2008 · GB/T 2951.14-2008 · GB/T 2951.21-2008 · GB/T 2951.31-2008 · GB/T 2951.32-2008 · GB/T 2951.41-2008
Editions of GB/T 31840.3
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 31840.3-2025 | Aluminum alloys power cables with extruded insulation for rated voltages from 1 kV(Um=1.2 kV) up to 35 kV(Um=40.5 kV) - Part 3: Cables for rated voltages 35 kV(Um=40 kV) | current edition | Current |
| GB/T 31840.3-2015 | Aluminum alloys power cables with extruded insulation for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV) -- Part 3: Cables for rated voltage of 35 kV (Um=40.5 kV) | previous edition | In force |
This page sells the current edition, GB/T 31840.3-2025. Earlier editions are listed for reference only.
How to Buy GB/T 31840.3-2025
- 1Add to cart. Click the "Buy GB/T 31840.3-2025" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 3048.10-2007 — Test methods for electrical properties of electric cables and wires - Part 10: Spark test of extruded protective sheaths
GB/T 3048.4-2025 — Test methods for electrical properties of electric cables and wires — Part 4: Test of DC resistance of conductors
GB/T 31840.1-2025 — Aluminium alloy power cables with extruded insulation for rated voltages from 1 kV up to 35 kV — Part 1: Cables for rated voltages of 1 kV and 3 kV
Secure payment via Stripe
Payments accepted
GB/T 31840.3-2025