GB/T 31470-2015Standard practice for determination of the specimen area contributing to the detected signal in Auger electron spectrometers and some X-ray photoelectron spectrometers (English PDF)
俄歇电子能谱与X射线光电子能谱测试中确定检测信号对应样品区域的通则
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 31470-2015 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 15, 2015
Implementation date
January 1, 2016
Scope
GB/T 31470-2015 is the English-translated version of 俄歇电子能谱与X射线光电子能谱测试中确定检测信号对应样品区域的通则.
GB/T 31470-2015 is the Chinese standard "Standard practice for determination of the specimen area contributing to the detected signal in Auger electron spectrometers and some X-ray photoelectron spectrometers".
Its scope clause reads: This standard specifies the method for determining X-ray photoelectron spectroscopy, Auger electron spectroscopy detection signals and some types of the corresponding sample area.
This standard applies to Auger electron spectroscopy and the following conditions X-ray photoelectron spectroscopy. an incident X-ray beam excited sample area Analyzer greater area of \u200b\u200bthe sample can be detected; optoelectronic through free space from the sample inlet to the analyzer process; auxiliary electronic assembly Gun can produce a bunch of variable energy electron beam onto the sample. Its clauses include terms and definitions; abbreviations; instruments.
Found what you need?
Document preview — GB/T 31470-2015
National Standard of the People's Republic of China
- ICS
- 17.220.20
- Classification
- N 26
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Abbreviations
- 5 Instruments
1 Scope
This standard specifies the method for determining X-ray photoelectron spectroscopy, Auger electron spectroscopy detection signals and some types of the corresponding sample area.
This standard applies to Auger electron spectroscopy and the following conditions X-ray photoelectron spectroscopy. an incident X-ray beam excited sample area
Analyzer greater area of the sample can be detected; optoelectronic through free space from the sample inlet to the analyzer process; auxiliary electronic assembly
Gun can produce a bunch of variable energy electron beam onto the sample.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 22461-2008 Surface chemical analysis - Vocabulary (ISO 18115.2001, IDT)
SJ/T 10458-1993 Auger electron spectroscopy and X-ray photoelectron spectroscopy technique surgery Standard Guide for sample preparation
3 Terms and Definitions
Terms and definitions GB/T 22461-2008 defined apply to this document.
4 Abbreviations
The following abbreviations apply to this document.
AES. Auger electron spectroscopy (Augerelectronspectrometer)
XPS. X-ray photoelectron spectroscopy (X-rayphotoelectronspectrometer)
FWHM. half-height width (fulwidthathalfmaximum)
5 Instruments
5.1 Sample
Recommended test sample is a metal foil type conductor, a lateral dimension greater than the size of the electron energy analyzer detection region. Grain sample
It should be less than the expected size of the spatial resolution of the analyzer, or the diameter of the incident electron beam, in order to avoid channel effects caused by the diffraction effect or illusion.
The sample surface should be smooth, no scratches and similar defects can be observed with the naked eye. Ion sputtering or other methods used to remove
Contamination of the sample surface (e.g., an oxide, the adsorbed hydrocarbons, etc.), surface cleanliness can be measured by XPS or AES verified.
5.2 electron gun
Equipment required to provide an electron gun incident on the sample surface spectrometer, resorted to a signal emitted electron beam energy 100eV ~ 3keV […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 31470-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 31470-2015
$145.00