Valid

GB/T 31437-2015Air-to-air heat exchanger unit for ventilation and air-conditioning (English PDF)

单元式通风空调用空气-空气热交换机组

Preview PDF

This is a limited preview

Buy now to download the full PDF (21 pages)

Need quotation for your management?

Get a formal quotation for GB/T 31437-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 15, 2015

Implementation date

December 1, 2015

Scope

GB/T 31437-2015 is the English-translated version of 单元式通风空调用空气-空气热交换机组.

GB/T 31437-2015 specifies the air-to-air heat exchanger units used for ventilation and air conditioning, covering the terms and definitions, the classification and marking, the general requirements, the requirements proper, the test methods, the inspection rules, the marking, packaging, transportation and storage, and the basic content of the random technical documents.

Clause 1 states that it applies to the units that take cold outdoor air as the cold source and cool the indoor air by indirect heat exchange between indoor and outdoor air, by bringing the outdoor air directly into the room, or by combining those two methods in a single unit.

Clause 3 defines the unit itself and then separates the direct heat exchange type, in which supply and exhaust fans move the air and the outdoor air is filtered and, after low temperature treatment, discharged directly into the room, from the indirect heat exchange type, in which indoor and outdoor air are moved by fans and exchange heat through a heat exchanger.

Four normative appendices give test methods for the air flow, the total pressure and the input power, for internal leakage, for the rated heat exchange and for the dust holding capacity of the unit, although the draft prints the titles of the last two with the words out of order.

Clause 2 cites nine documents, among them GB 755 on rotary motors, GB/T 1236-2000 on the performance testing of industrial fans, GB 4706.1-2005 on the safety of household and similar electrical appliances, GB/T 9068-1988 on the sound power level of heating, ventilation and air conditioning equipment, GB 10080 on air conditioning fan safety, GB/T 14295-2008 on air filters, and the two YD/T documents on flame retardant flexible cables and on constant temperature and humidity air conditioning systems for communications rooms.

The foreword records that the standard was proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China and is centralized by the National HVAC and purification equipment Standardization Technical Committee (SAC/TC143).

The draft published on the page breaks off inside the definition of the indirect heat exchange type, so the requirements, the test methods and the inspection rules themselves cannot be read. It was issued on 15 May 2015 and has applied since 1 December 2015.

Found what you need?

Document preview — GB/T 31437-2015

National Standard of the People's Republic of China

ICS
91.140.30
Classification
P 48

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 5 4 General requirements Requirements 5
  • 7 Test methods
  • 10 8 Inspection Rules
  • 9 signs, packaging, transportation and storage
  • 10 random elements of the technical documentation
  • Appendix A (normative) air flow, total pressure and input power outlet Test Method
  • Appendix B (normative) Internal leakage test method Heat test method in Annex C (normative) Rated change

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules.

The standard proposed by the Ministry of Housing and Urban-Rural Development of the People's Republic of China.

1 Scope

This standard specifies the ventilation air conditioning unit with air - air heat exchanger terms and definitions set, classification and marking, general requirements, to Requirements, test methods, inspection rules, marking, packaging, transportation and storage, the basic content of random technical documents and the like.

This standard applies to cold outdoor air as cold source, the indoor air with outdoor air by indirect heat exchange or by the outdoor air into Indoor direct heat exchange methods and the combination of the above two methods into one way to achieve indoor air heat exchanger cooling air - air heat exchanger Change unit.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB 755 rotary motor fixed and performance

GB/T 1236-2000 Industrial fans using standardized airways performance test Part 1

GB 4706.1-2005 Safety of household and similar electrical appliances. General requirements

GB/T 9068-1988 Determination of heating, ventilation and air conditioning equipment noise sound power levels - Engineering method

GB 10080 Safety requirements for air conditioning fan

GB/T 14295-2008 Air Filter

GB/T 16803-1997 heating, ventilation, air conditioning, cleaning terminology

YD/T 1173 communication power flexible cables with fire retardant

YD/T 2061 communications room with a constant temperature and humidity air-conditioning systems

3 Terms and Definitions

GB/T 16803-1997 define the following terms and definitions apply to this document.

3.1 Ventilation air conditioning unit with air - air heat exchange unit

In cold outdoor air as cold source, the indoor air with outdoor air by indirect heat exchange or by the outdoor air heat exchanger directly into the room Combinations or using the above two methods into one heat exchanger, to achieve indoor air cooling air - air heat exchange unit (hereinafter Referred to as "unit").

3.2 Direct heat exchange unit type

In cold outdoor air as cold source, air supply fan, exhaust fan for the air transport power source, through the outdoor air filter cryogenic treatment After discharge directly into the indoor heat exchanger to achieve indoor air cooling function of the unit. […]

3.3 Type indirect heat exchange unit

The outdoor air is low temperature cold source, indoor and outdoor air circulation fan for the power delivery source of heat exchanged air through the heat exchanger, lowering

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 21 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 31437-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
21 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 31437-2015

$355.00